Forced Air Drying Incubator

The forced air drying oven heats air through electric heating elements, and a fan forces the circulation of hot air to ensure uniform temperature inside the chamber. It is used for processes such as sample drying, heat treatment, and curing. It is suitable for constant-temperature drying of materials in laboratories.
Selection
When selecting, consider that the temperature range meets experimental requirements, the inner tank material is corrosion-resistant, the fan performance ensures uniform temperature, the insulation effect of the chamber impacts energy consumption, the control method is chosen based on precision requirements—mechanical or microcomputer—and safety features include over-temperature protection.

Standards

Instruments

Using forced warm air circulation to ensure uniform temperature, Temperature resolution of 0.1 ℃, equipped with microcomputer LCD controller temperature control is accurate, mirror stainless steel liner is easy to clean, the door opens automatically stop heating.

$ 457.00

Temperature range foster RT + 5~ 80 ℃, drying 80~ 220 ℃, Temperature Fluctuation +/- 0.5 ℃, mirror stainless steel liner is easy to clean.

$ 638.00

Adopt vertical double air duct air jacket and turbine centrifugal forced air supply, Temperature Uniformity +/- 1.0 ℃, Fluctuation +/- 0.5 ℃, support 0-9999 minutes timing and automatic stop function, with over-rise prevention and low water level alarm.

$ 1539.00

Temperature range foster RT + 5~ 80 ℃, drying 80~ 250 ℃, Temperature Fluctuation +/- 0.5 ℃ to +/- 1 ℃, forced warm air circulation to ensure uniform temperature, mirror stainless steel liner easy to clean.

$ 761.00

With drying and foster dual mode automatic conversion function, Temperature Fluctuation foster +/- 0.5 ℃, drying +/- 1 ℃, using fan forced convection and autonomous air duct circulation system, improve Temperature uniformity and automatic discharge of water vapor.

$ 459.00

Mirror stainless steel liner is easy to clean, Temperature range foster RT + 5~ 80 ℃, drying 80~ 250 ℃, Temperature Fluctuation +/- 0.5 ℃ or +/- 1 ℃, with forced warm air circulation and timing function to ensure uniform and stable temperature.

$ 470.00

Temperature range foster RT + 5~ 80 ℃, drying 80~ 220 ℃, using mirror stainless steel liner and forced convection technology to ensure uniform temperature, four corners and a half arc easy to clean, the door opens automatically stop heating.

$ 1125.00

Temperature range foster RT + 5~ 80 ℃, drying 80~ 220 ℃, Temperature Fluctuation +/- 0.5 ℃, forced warm air circulation to ensure uniform temperature, mirror stainless steel liner is easy to clean, the door opens automatically stop heating.

$ 553.00

Forced circulation convection air duct to ensure uniform temperature, Temperature range Rt + 10~ 200 ℃, Temperature Fluctuation +/- 1 ℃, with over-temperature alarm and up to 9999 minutes timing function, suitable for a variety of non-flammable and explosive materials processing.

$ 561.00

Temperature uniformity is ensured by forced circulation convection air duct, temperature control accuracy of 0.1 ℃, with Sensor fault alarm and over-temperature protection function, Timer Range can be selected from 0-9999 minutes or hours, suitable for a variety of non-flammable and explosive materials processing.

$ 659.00

Dual duct forced convection design makes Temperature Uniformity up to +/- 1.0 ℃, Fluctuation +/- 0.5 ℃; Speed control fan supports lightweight Sample Handling, low water level alarm and forced cooling structure to improve safety, support 0~ 9999 minutes timing.

$ 909.00

The vertical double air duct air sleeve structure is combined with the turbine centrifugal forced air supply, the Temperature Uniformity is up to +/- 2.5%, the speed regulating fan can handle light powder samples, and the forced heat dissipation design ensures that the operating temperature of the fan is lower than 50 ° C.

$ 732.00

Adopt vertical double air duct air jacket and turbine centrifugal forced air supply, Temperature Uniformity +/- 2.5%, equipped with speed regulating fan to support lightweight Sample Handling, over-rise alarm and menu lock to ensure safe and reliable operation.

$ 651.00

Fuzzy PID controller is used to ensure accurate temperature fluctuation, forced convection duct to raise Temperature uniformity to +/- 1.5 ℃, automatic control of circulating fan speed to avoid sample volatilization, mirror stainless steel liner and electric heating film Heating mode to achieve rapid and uniform heating.

$ 804.00

Vertical double air duct air sleeve with turbine centrifugal forced air supply, Temperature Uniformity of +/- 2.5%; Speed control fan supports lightweight and small Sample Handling to ensure long-term stable operation of the equipment.

$ 942.00

Articles