Portable Ammonia Gas Analysis System

The portable ammonia analyzer uses electrochemical or optical sensors to detect the concentration of ammonia molecules in the air. It directly displays the readings through gas sampling and signal conversion. It is used for on-site rapid detection of ammonia leaks in industrial environments, farms, chemical storage tanks, and other areas to ensure operational safety.
Selection
When selecting, focus on whether the detection range covers the needs of the application scenario, the impact of sensor lifespan and calibration cycles on usage costs, the equipment's protection level suiting the on-site environment, data recording functions meeting regulatory requirements, and response speed and accuracy complying with detection standards.

Terms

Standards

Instruments

Dedicated to calibrating ammonia Gas sensing electRodes, capacity 250ml, providing accurate calibrating support to ensure Reliability of detection data.

$ 110.00

250Ml Encasement Specification for Ammonia Gas Sensitive and Ammonium Ion Composite ElectRode, provides routine concentration adjustment for measurement accuracy and Stability.

$ 127.00

Measurement range pN value of 0.00~ 8.00, ammonia nitrogen concentration of 0.05~ 1000mg/L, with automatic mixing and thermostatic system, anti-sample Color, metal ions and turbidity interference, support a variety of reading methods.

$ 1806.00

Designed for Ammonia Gas Sensitive Compound ElectRode, it provides a stable reference potential to ensure accurate measurement. The Encasement specification is 250ml, which is suitable for long-term monitoring applications.

$ 143.00

ElectRode filling solution, suitable for ammonia Gas sensing electRode maintenance, capacity 480 ml, can effectively adjust the ionic strength, improve ElectRode Response Speed and Measurement accuracy.

$ 135.00

ElectRode filling solution is suitable for ammonia Gas sensing electRode maintenance, copper ion type, capacity 480 ml, to ensure ElectRode performance stability and measurement accuracy.

$ 135.00

ElectRode filling solution is suitable for ammonia Gas sensing electRode maintenance, providing bromine ion type and 480mL capacity to ensure stable ElectRode performance.

$ 135.00

The filling liquid capacity of 30mL, the use of PTFE bottles, Dimension 65mm high × 30mm diaMeter, weight of only 20g, suitable for the maintenance of Ammonia Gas sensing electRode.

$ 135.00

Detect NH3 gas, range 0~ 100ppm, resolution 0.1ppm, Response Time T90 ≤ 120s, support sound and light alarm, Operating temperature -10~ 50 ℃, Working time for more than 60 hours, Portable design weighs only 170 grams.

$ 328.00

Using 8-bit microcontroller, Response Time is less than 30 seconds, with IP65 Protection Rating and sound and light vibration alarm function, support 1000 sets of alarm record storage.

$ 235.00

Using LED @575nm Illuminant and Nessler Measuring method, Measurement range 0.00-3 ppm, accuracy +/- 0.03ppm, suitable for low concentration ammonia nitrogen rapid detection, easy and economical operation.

$ 209.00

Composite ElectRode design, with 60mL reference filler and calibrated solution, built-in BNC connector, support for replaceable membranes for easy maintenance and long-term use.

$ 444.00

Measurement range covers 0.05-1000 mg/L, glass sensitive film design, temperature range 5-45 ℃, equipped with Q9 connector to ensure stable detection of ammonia nitrogen content.

$ 504.00

Measurement range 0.000~ 4.000mg/L, including Noll Reagent and potassium sodium tartrate solution, suitable for rapid detection of ammonia nitrogen in water quality, supporting special instruments.

$ 164.00

Colorimetric measurement based on Nasler method, Measurement range 0.00-10 mg/L, providing 100 tests, accurate determination of ammonia nitrogen concentration by Color intensity change.

$ 212.00

Articles

Handheld viscosity cups are used for rapid assessment of paint viscosity at construction sites.
A handheld viscosity cup is a portable tool used to quickly assess the viscosity of coatings at construction sites. It operates based on the flow-out time method, calculating viscosity by measuring the time it takes for the coating to flow out of the cup's orifice. It is suitable for Newtonian or approximately Newtonian fluids.
Advantages of Barcol Hardness Tester in Rapid On-site Coating Hardness Testing
The Barcol hardness tester is a portable device suitable for rapid on-site measurement of coating hardness. It determines the hardness value by measuring the depth of penetration of the indenter, offering simple operation and test completion within seconds.
How to choose between laboratory benchtop and portable water quality testing instruments
When selecting a water quality analyzer, the primary consideration is whether the testing task is conducted in a laboratory or on-site. Benchtop analyzers are suitable for laboratories, offering high precision, excellent stability, and the ability to handle large sample volumes. Portable analyzers are designed for fieldwork or emergencies, emphasizing rapid results, ease of operation, and strong environmental adaptability.
How to Choose Between IPX3 and IPX7 for a Rain Test Chamber? Understand the Rating Comparison Table and You'll Know
The rain test chamber is used to simulate product waterproof testing, with its core being the IP protection rating. IPX3 represents protection against spraying water, simulating rain splashes through a swinging pipe spray, suitable for outdoor lighting fixtures, etc. IPX7 represents protection against short-term immersion, simulating water submersion through soaking, suitable for portable devices.