High Light Incubator

The strong light incubator simulates specific light and temperature environments through its light source and temperature control system, and is used for plant growth research, seed germination testing, and photostability experiments.
Selection
When selecting, consider the light intensity range and uniformity, temperature control precision, cabinet size and sample capacity, energy consumption and heat dissipation design, ease of use of the operation interface, and maintenance costs.

Terms

Standards

Instruments

Dual beam of light path structure and 1600L/mm high performance grating, Wavelength range 190-1100nm, stray light ≤ 0.03% T, equipped with color Touchscreen and Automatic calibration function, support a variety of Data analysis and map processing operations.

$ 5237.00

Adopting mirror stainless steel liner and unique air duct circulation to ensure Temperature Uniformity +/- 1.5 ℃, 24-stage program can be set to simulate day and night changes, support 0~ 12000LX four-level adjustable light, safe temperature limit alarm.

$ 1369.00

Equipment provides a variety of standard illuminant options, maximum support three Illuminant, high CRI = 98, with Illuminant Timer, uniform lighting, easy to operate, suitable for Color Comparison.

$ 848.00

Adopt standard double beam of light path structure, equipped with 1600L/mm high performance holographic blazing grating, wavelength Precision +/- 0.3nm, stray light ≤ 0.03% T, with Automatic calibration wavelength error function, support a variety of data map processing.

$ 4914.00

Using 380-1000nm Light spectrum instrument to achieve comprehensive measurement of total light transmitance, haze, color coordinates, etc. Precision wavelength +/- 0.3nm, built-in integrating sphere coating stable and durable, a variety of fixtures to meet the needs of liquid solid sample testing.

$ 20729.00

Adopt standard double beam of light path structure, equipped with 1600L/mm high performance holographic blazing grating and imported photoelectric converter, wavelength Precision +/- 0.5nm, stray light ≤ 0.03% T, with Automatic calibration wavelength error function.

$ 4592.00

1200L/mm UV dedicated grating ensures low stray light and high resolution, proportional dual beam of light design supports a variety of test functions, equipped with automatic octagonal cell sample holder and 7-inch Touchscreen, Wavelength range 190~ 1100nm.

$ 4592.00

1200L/mm UV dedicated grating to ensure low stray light and high resolution, proportional double beam of light design with automatic octave cell sample holder to improve test efficiency, with automatic wavelength correction function and a variety of test modes.

$ 3268.00

Integrated Incubator and Shaker functions, Oscillation Frequency 40~ 300rpm, Temperature range RT + 5~ 65 ℃, 304 stainless steel liner and microcomputer PID control, with UV sterilization and automatic storage setting paraMeters.

$ 1427.00

Using 1200L/mm grating and C-T monochromator structure, Light spectrum Bandwidth 4nm, Wavelength range 330~ 1000nm, High Linear and Stability, Support a variety of Measurement modes.

$ 364.00

Optical inspection system with dual beam of light feedback compensates for Illuminant fluctuation in real time, Light spectrum reflectance Repeatability Standard Deviation is less than 0.1%, and the inter-device difference Delta E * ab is as high as 0.08, which can accurately measure fluorescent materials without UV correction.

$ 27183.00

Integrated Incubator and Shaker functions, small footprint and large bottle load; Temperature range 4~ 65 ℃, Temperature Fluctuation +/- 0.2 ℃; 304 stainless steel liner for easy cleaning, quiet operation and support multi-stage programming.

$ 2315.00

1200L/mm UV dedicated grating and proportional double beam of light design, Wavelength range 190~ 1100nm, stray light ≤ 0.03% T, support automatic correction of wavelength error and a variety of test functions to ensure High Accuracy and Long-term Stability.

$ 2494.00

Using 1200L/mm grating and C-T monochromator structure, Light spectrum Bandwidth 4nm, Wavelength range 325~ 1000nm, to ensure High Accuracy Testing and Stability, wide sample Chamber supports 100mm sample holder.

$ 356.00

Dual Light spectrum analysis technology, Wavelength range 360~ 780nm, Support SCI + SCE simultaneous fast measurement, Automatic calibration and Temperature Humidity Compensation to ensure High Accuracy and Stability.

$ 11337.00

Articles

Impact of the Fixture Design of a Drop Hammer Impact Tester on the Plastic Impact Strength Results
This article primarily discusses the impact of the fixture design of a drop-weight impact testing machine on the results of plastic impact strength tests. The geometric parameters of the fixture, clamping method, and contact surface material can alter the stress state and energy transfer of the specimen, thereby affecting the accuracy of the test data.
Application of High-Temperature Universal Testing Machine in the Study of Hot Modulus of Rupture of Refractory Materials
This article introduces the application of a high-temperature universal testing machine in measuring the hot modulus of rupture of refractory materials. It explains the working principle, testing procedure, and key parameters of the testing machine, such as the effects of heating rate, holding time, and loading rate.
Application of Tensile Testing Machine in 180-Degree Peel Strength Test for Packaging Tape
This article introduces how a tensile testing machine is used to test the 180-degree peel strength of packaging tape.
Constant temperature bath selection: circulation method and temperature control range.
This article on thermostatic bath selection primarily analyzes two core factors: circulation mode and temperature control range. The circulation mode is divided into natural convection and forced circulation, where the former is suitable for simple static experiments, while the latter offers higher precision and is better suited for multiple samples or integration with external devices.
Electronic Tensile Testing Machine Measures the Right-Angle Tear Strength of Films
This article explains how to measure the right-angle tear strength of films using an electronic tensile testing machine. During the test, a film specimen with a right-angle notch is first clamped onto the testing machine and stretched at a constant speed. The machine records the changes in force during the tearing process.
UV-Vis-NIR spectrophotometer measures the transmittance of anti-reflection coatings.
This article introduces the method of measuring the transmittance of anti-reflective coatings using a UV-Vis-NIR spectrophotometer. The instrument is based on the Beer-Lambert law, calculating transmittance by comparing the light intensity of the sample and the reference, covering a wide spectral range from ultraviolet to near-infrared.
Pendulum Impact Tester Evaluates Impact Strength of Glass Fiber Reinforced Nylon
This article introduces the use of a pendulum impact tester to evaluate the impact strength of glass fiber reinforced nylon. The test is based on the principle of energy conservation, where the energy absorbed by the material is calculated by measuring the height difference of the pendulum before and after impacting the specimen, thereby quantifying its impact resistance.
Heat Deflection Temperature Tester for Measuring the Thermal Resistance of Carbon Fiber Reinforced Plastics
This article introduces the method of testing the heat resistance of carbon fiber-reinforced plastics using a heat deflection temperature tester. The instrument applies a fixed load to the material while increasing the temperature, measuring the temperature at which the material reaches a specified deformation, thereby evaluating its short-term resistance to thermal deformation.
Transmittance Tester Measures the Clarity of Optical Films
This article introduces how to use a transmittance tester to measure the clarity of optical films. Clarity refers to the fidelity of imaging after light passes through the film. The tester is based on the principle of light transmission, calculating the clarity value using a formula by measuring the intensity of parallel transmitted light and scattered light.
Peel strength tester measures interlayer force of composite films.
This article introduces how a peel strength tester measures the interlayer bonding force of composite films. Composite films are widely used in packaging and other fields, and their interlayer peel strength is a key indicator for evaluating durability.
Heat Sealing Tester Determines the Optimal Heat Sealing Temperature for Films
A heat seal tester is used to determine the optimal heat sealing temperature of films to ensure the sealing strength and integrity of packaging. During testing, by setting a temperature gradient and fixing parameters such as pressure and time, samples are heat-sealed at different temperatures, and then their strength is measured.
Electronic universal testing machine measures film tensile strength.
This article introduces the method of measuring the tensile strength of thin films using an electronic universal testing machine. During the test, the machine applies tensile force to the film sample, records the maximum tensile force and displacement through sensors, and then calculates the tensile strength using a formula.
Selection of impact head diameter and drop hammer mass combination for paint film impact tester
When selecting the impactor diameter and drop hammer mass for a paint film impact tester, the key is to balance the impact energy and pressure.
Universal Testing Machine evaluates the mechanical properties of carbon fiber reinforced resin.
This article introduces how to use a universal material testing machine to test the mechanical properties of carbon fiber-reinforced resin. Carbon fiber-reinforced resin is widely used in aerospace and other fields due to its lightweight and high strength.
Compression strength tester evaluates the compressive capacity of highly filled resins.