Using double-sided uniform tin plating process, the surface mass reaches class I, Hardness is T52, standard thickness is 0.28mm, to ensure accurate and reliable film test results.
Double-sided uniform tin plating, surface mass I, Hardness T52, standard thickness 0.28mm, provide crimping listening plate, rounded corners with or without holes and other specifications, single batch pRoduction of 10w sheets.
Reagent grade chemicals can minimize the growth of ElectRode bacteria and keep the Glass film moist, 500mL capacity unopened valid period of up to 5 years, suitable for ElectRode cleaning and then hydration.
Using double-sided uniform tin plating process, the surface mass reaches class I, Hardness T52, standard thickness 0.28mm, to ensure accurate and reliable film test results.
With 15 °, 45 °, 110 ° three-angle measurement function, can simultaneously obtain Color data, flicker and particle grade; built-in automatic white calibrating, no human intervention; with stable long-life LED Illuminant, the service life is up to 10 years.
Using rigid polyester plate with foam rubber cushion, size 240x340mm, can absorb operating pressure, improve proofing Repeatability and uniformity, suitable for a variety of substrate testing.
The total film width of 90mm is divided into 10 gaps, the depth is gradually increased by 25μm, and the spacing is 1.5mm. The removable guide plate design is easy to operate on different thickness test panels.
Using DAIDO 440C medical grade stainless steel material, after sub-zero vacuum hardening to HRC55 Hardness, wet film thickness 100μm, application width 75mm, accuracy control within +/- 2μm, suitable for a variety of smooth plane.
Cube Applicator can achieve 70/150μm double-sided Film thickness Spreader, through the hardening process to ensure that the overall uniform hardening, Spreader width 12mm, guide plate design for narrow Glass panel direct use.
Using brushless DC motor to achieve stepless speed regulation of 0~ 2000rpm, aluminum alloy heating plate Power 600W rises rapidly, temperature control accuracy +/- 1 ℃, heating plate temperature can be directly set and with safety restrictions.
Designed with 90mm application width and 25μm Graduation, with removable guide plate to ensure direct stretching, the sagging index is assessed through 10 aliquots, meeting ASTM standards.
Four-speed proofing speed is optional, up to 45m/min, using flat engraving plate for direct printing, supporting 95 × 149mm concave sample range, suitable for fast proofing of flexible substrates.
Using DAIDO 440C medical grade stainless steel material, after sub-zero vacuum hardening to HRC55 Hardness, application width 75mm, wet film thickness 50μm, overall accuracy +/- 2μm, suitable for smooth flat surface Spreader operation.
Grinding hard chrome metal pressure plate, adjustable temperature range -10~ 80 ℃, equipped with 10 point temperature transducer, through drying air flow to prevent condensation, ensure test repeatability, in line with a number of international standards.
Using electromagnetic force equilibrating Sensor, accuracy of 0.01mN/m, support platinum plate and platinum ring method, automatic measurement without calculation, real-time display Linear dispersion and save the results.