Fully Automatic Whiteness Measurement System

The fully automatic whiteness meter measures the intensity of blue light reflected from an object's surface using a photoelectric sensor and calculates the whiteness value by comparing it with a standard whiteboard. It is used for whiteness detection of materials such as paper and plastics to ensure product color consistency. During operation, it automatically places samples and outputs data.
Selection
When selecting, consider that the measurement range should cover the whiteness range of the samples and align with industry standards such as ISO 2470. Pay attention to an instrument repeatability error of less than 0.5% and ensure it has automatic calibration functionality. Choose an appropriate fixture based on the sample form to guarantee both detection efficiency and data reliability.

Terms

Standards

Instruments

Adopt 32-bit ARM processor to improve data processing speed, equipped with 5-inch true color Touchscreen to simplify the operation process, support one-click whiteness and chroma testing, Repeatability color coordinates ≤ 0.0003.

$ 3026.00

Can measure ISO blue light whiteness and fluorescence whiteness, support powder whiteness measurement, Repeatability ≤ 0.02, built-in thermal printer, data can be cached and power-off protection, equipped with RS232 interface for easy communication.

$ 1051.00

Using R457 whiteness formula, blue light whiteness and fluorescence whiteness can be measured simultaneously, Repeatability ≤ 0.3, Operating temperature 5~ 35 ℃, optical path design is simple to ensure measurement accuracy and Repeatability.

$ 432.00

Fully automatic one-click measurement of a variety of whiteness paraMeters, support chromaticity coordinates ≤ 0.001 High Accuracy, built-in thermal printer and RS232 interface, suitable for powder, paper and other samples.

$ 1818.00

Can measure ISO whiteness and fluorescence whiteness, equipped with diffuse ball diaMeter 150mm, test hole 19mm, support light scattering coefficient, absorption coefficient and other Optical inspection paraMeters, suitable for a variety of material surface whiteness analysis.

$ 1174.00

R457 blue light whiteness formula, Measurement range 0~ 199.9%, resolution 0.1, Basis Weight measurement of whiteness of fluorescent whitening objects and paper Opacity, suitable for a variety of materials surface flat samples.

$ 332.00

Repeatability of 0.2 for measurement of diffuse reflection factor using 457 nm blue wavelength can detect Fluorescent Whitening Agent and calculate fluorescence whiteness value, which is suitable for surface whiteness analysis of various materials.

$ 554.00

Using LED Illuminant and 45/0 illumination conditions, Measurement range 0~ 199.9, resolution 0.1, can detect Fluorescent Whitening Agent and measure increased whiteness, Repeatability ≤ 0.3.

$ 417.00

R457 blue light whiteness formula, Measurement range 0~ 100%, resolution 0.1, Repeatability ≤ 0.3, suitable for fluorescent whitening objects and paper Opacity measurement.

$ 490.00

Using LED Illuminant, 45/0 illumination conditions, Measurement range 0~ 199.9, Repeatability ≤ 0.3, suitable for whiteness measurement of white objects or powders, easy to carry and on-site detection.

$ 393.00

Measurement time is only 1.5 seconds, Repeatability is less than R0.1, which can measure a variety of whiteness indicators and reflectance, and is suitable for the analysis of fluorescent whitening samples.

$ 800.00

With simulated D65 light source and a 150mm integrating sphere, it can complete fluorescence whiteness testing with one click, eliminating the need for manual switching. It features a dust-proof structure that effectively protects the optical system, ensuring accurate and stable measurements.

$ 1655.00

Using blue light whiteness R457 standard, Measurement range 0~ 100, Repeatability ≤ 0.5, Basis Weight can reflect fluorescent whitening effect and accurate measurement paper Opacity.

$ 654.00

R457 blue light whiteness measurement, Indication Error +/- 2.5, repeatability error ≤ 0.3, equipped with 10V/30W halogen tungsten lamp light source to ensure stable reflection performance detection.

$ 687.00

Automatic calibration without preheating zero adjustment, 1.5 seconds fast measurement, accuracy of 0.1, equipped with 4mm small diaMeter measurement head, support connecting mobile app and computer software to achieve Data storage and report export.

$ 202.00

Articles

Paper Whiteness Tester Measures CIE Whiteness
This article explains how a paper whiteness meter measures CIE whiteness. Whiteness is a crucial optical indicator for evaluating paper quality. Traditional methods rely on subjective judgment, while modern instruments provide objective data by simulating standard lighting conditions.
Principle and Application of Whiteness Meter in Measuring Coating Whiteness
A whiteness meter quantifies the whiteness of paint samples by simulating human perception of white, measuring the diffuse reflectance of light—particularly in the blue wavelength range—and converting it into a numerical whiteness value. It employs standardized optical configurations and mathematical models, such as the Ganz formula, to assess the brightness and chromaticity of coatings.
Calibration and Use of Paper Whiteness Tester
This article introduces the working principle, calibration process, operational steps, and factors influencing the measurement results of a paper whiteness tester. The instrument evaluates whiteness by measuring the reflectance of blue light from paper, and calibration requires the use of a standard whiteboard in accordance with relevant standards.
Application of Whiteness Meter in the Evaluation of Paper Brightness and Visual Comfort
The whiteness meter quantifies the brightness and whiteness of paper by measuring its reflected light characteristics, following international standards such as ISO to ensure comparability of results. The brightness of paper affects visual comfort, and moderate whiteness can enhance the reading experience, but excessive whiteness may lead to fatigue.
Whiteness meter measures the whiteness of white pigments
This article introduces the standard method for measuring the whiteness of white pigments using a whiteness meter. Whiteness is an important optical indicator for evaluating the quality of white pigments, and a whiteness meter can provide objective measurements.