Suitable for low conductivity water samples with conductivity above 100 µS/cm, using polymer liquid junction design, pH Measurement range 0-11pH, Temperature Measurement range 0-80 ℃, no need to add liquid reference system.
Measurement accuracy of 0.01 pH, support automatic temperature compensation and pH/mV/temperature Multi-ParaMeter measurement, simple, stable and reliable operation.
Measurement range 0.00-14 pH, accuracy +/- 0.05pH, with temperature compensation function, portable design for easy field use, large screen LCD display is clear and intuitive.
Measurement range 0.00-14 pH, accuracy +/- 0.05pH, with automatic temperature compensation function, portable design for on-site fast detection, repeatability error only +/- 0.03.
Support Bluetooth wireless communication for easy setting and data download, pH Measurement accuracy +/- 0.10pH @+/- 10 ℃, suitable for fresh and salt water environment, user can replace battery and ElectRode, Protection Rating IP68.
Glass bulb sensitive film, Measurement range 0-14pH, suitable for low Conductivity Detector sample measurement under closed static conditions, Dimension Φ 12 × 120mm.
Fast Response with Planar pH ElectRode, Automatic temperature compensation and 1-3 point Adjustment, Measurement accuracy of 0.01 pH, Support automatic end point locking and full waterproof design.
Suitable for 0~ 80 ℃ high temperature environment, Measurement accuracy of 0.01pH, Sensitivity high, more than 60 ℃ can still work stably, with Calomel electRode through potential changes reflect the pH value of the solution.
Measurement accuracy up to +/- 0.05PH, Repeatability +/- 0.03PH, equipped with LCD large screen display, support data retention and automatic temperature compensation function, easy and reliable operation.
Measurement accuracy of +/- 0.02pH, resolution of 0.01pH, support three-point calibrated, built-in Glass electRode, small size weighing only 88g, suitable for 0-50 ℃ environment, easy to quickly detect on site.
Equipped with planar pH ElectRode, Measurement accuracy is 0.05pH, support 2 point calibrating and automatic temperature compensation, fully waterproof design and replaceable ElectRode, prolong service life.
With PH/ORP measurement function, Measurement accuracy up to +/- 0.02pH, support temperature automatic compensation and manual compensation, provide high and low limit alarm dual relay, isolated transmitter port maximum loop resistance greater than 300Ω.
With 0.01 pH Accuracy and +/- 0.2 ° C temperature accuracy, support automatic temperature compensation and ElectRode diagnostic functions, Data storage 450 sets and can be output through U disk.
With automatic temperature compensation and manual quick Adjustment, pH Measurement accuracy of +/- 0.01pH, ORP range of +/- 1999mV, BEPS low power error prevention system to ensure stable operation in harsh environments.
Using external ElectRode design, Measurement accuracy of 0.01pH, support 0.1-14 pH range and 0-50 ℃ temperature measurement, small size for on-site detection and operation.