Online Viscosity Monitor

The online viscometer measures fluid resistance in real-time through rotating or vibrating sensors, directly displaying viscosity changes. It is used in production processes such as coatings and inks to monitor material consistency and ensure process stability.
Selection
When selecting, consider matching the fluid properties with the sensor type, ensuring the process pressure and temperature ranges align with operating conditions, the protection rating suits the environment, the output signal is compatible with the existing control system, and regular calibration and maintenance ensure data accuracy.

Terms

Standards

Instruments

Adopt photometric 90 ° scattering measurement method, equipped with automatic cleaning brush and bubble measurement cell, support automatic sewage discharge and cleaning interval setting, Measurement range 0.00-500 NTU, Repeatability ≤ 2%.

$ 2783.00

Micro vibration technology implementation of real-time online measurement, range 0~ 50~ 100mpa.s, accuracy +/- 0.5%, Response Time 2 seconds, suitable for a variety of fluid media.

$ 7335.00

Micro vibration technology implementation of real-time online measurement, range coverage of 0-5~ 50-5000pa.s, accuracy of +/- 0.5%, temperature 500 ℃ and Response Time only 2 seconds, suitable for high temperature and high voltage conditions.

$ 7335.00

With Humidity continuous automatic correction function, effectively reduce Humidity interference; Measurement range 0.001-100mg/m ³, support TSP, PM10, PM5, PM2.5, PM1.0 multi-cutter compatibility, built-in filter membrane sampling device to achieve continuous monitoring and sampling.

$ 2542.00

Micro vibration technology implementation viscosity measurement, range 0-5000mpa.s, accuracy +/- 0.5%, Response Time 2 seconds, with IP68 Protection Rating and a variety of connection methods.

$ 7335.00

The laser light scattering principle to achieve rapid measurement, detection sensitivity of 0.001mg/m ³, with online automatic mechanical Adjustment, built-in optical path self-cleaning system to avoid contamination of core components, support a variety of cutter selection.

$ 5399.00

Fast measurement using laser light scattering principle, with online automatic mechanical Adjustment, Measurement range 0.01-100 mg/m ³, built-in optical path self-cleaning system to avoid pollution, support a variety of cutters and sampling modes.

$ 5399.00

Rotation speed up to 26000rpm, providing 27m2/s shear line speed, long-term stable operation, fine and uniform processing of materials, no dispersion dead angle, suitable for high viscosity up to 10000CP working conditions.

$ 2654.00

Adopt pre-treatment technology, adapt to high temperature, humidity and dust environment, equipped with 7-inch Touchscreen real-time display concentration Linear dispersion, detection error ≤ +/- 3% F.S, support 4-20mA and RS485 output, can realize automatic drainage and zero emission cycle function.

$ 1493.00

500Ml capacity S6 viscosity standard oil, 20 ℃ viscosity 8.911mPa · s, 25 ℃ viscosity 7.498mPa · s, traceable to national standards, compatible with a variety of test equipment calibrating requirements.

$ 472.00

The melting temperature error is only +/- 1 ° C, allowing for remote observation of the melting state. It can be directly pasted without complex installation and is suitable for temperature monitoring of a variety of electrical equipment.

$ 89.00

Silicone oil standard liquid viscosity value 11000cp, capacity 400ml, specially designed for Viscometer calibrated, providing stable and reliable viscosity reference standards.

$ 204.00

Using 6mm filter diaMeter, viscosity measurement range 188-684cSt, flow time 30-100 seconds, in line with international standards design, suitable for rapid viscosity evaluation of newtonian fluids, aluminum alloy structure to ensure durability.

$ 432.00

The rated temperature is 55 ° C and the error is only +/- 1 ° C. The melting situation can be observed remotely, and it can be directly pasted for use in busbars or equipment terminals to monitor temperature changes.

$ 87.00

The brushless motor can run stably for a long time, the highest Rotation speed is 30000rpm, the shear line speed is 27m ²/s, the unique stator and rotor structure provides super strong shear force, and the processing without dispersion dead angle is more fine and uniform.

$ 2171.00

Articles

How to choose the right rotational viscometer?
This article introduces how to select an appropriate rotational viscometer, so you won't be blind when choosing a viscosity measurement instrument!
How to choose a laboratory coater? Which one should you buy: wire bar, scraper, or slot die?
This article introduces three methods for selecting laboratory coating machines: wire bar coating is suitable for low-viscosity coatings, offering low cost and simple operation; blade coating is ideal for medium-to-high viscosity slurries or those containing particles, with a wide range of film thickness control; slot-die coating provides the highest precision and is suitable for high-end applications such as electronic films.
Laboratory blade coating machine is used for analyzing the film-forming characteristics of high-viscosity slurries.
This article analyzes the characteristics of a laboratory doctor blade coater for forming films from high-viscosity slurries. It focuses on the impact of slurry rheological properties on film formation quality.
Effect of Different Coating Speeds on Film Thickness Consistency in an Adjustable Film Applicator
This paper studies the influence of coating speed of an adjustable film applicator on film thickness uniformity. In the experiment, the coating blade gap was fixed at 100 μm, and a resin solution with a viscosity of 200 mPa·s was used to prepare films at five speeds ranging from 10 to 80 mm/s, followed by thickness measurements.
Stormer viscometer controls the in-can viscosity of latex paint.
This paper introduces the application of the Stormer viscometer in controlling the paint can viscosity of latex paint. Paint can viscosity affects application performance and user experience, with either too high or too low values causing issues.
Rotation rheometer evaluates the atomization performance of water-based paint spraying.
This article introduces how to evaluate the atomization effect of water-based paint spraying using a rotational rheometer. It first explains the two stages of atomization, as well as the importance of rheological parameters such as shear viscosity, storage modulus, loss modulus, and complex viscosity.
Application of Laboratory Scraper Heating Coating Machine in Hot Melt Adhesive Coating
This article introduces the application of a laboratory blade heating coating machine in hot melt adhesive coating. It first explains the coating process and principles, including three stages—heat conduction, fluid shear, and surface wetting—as well as the influence of temperature on adhesive viscosity.
Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Application of Cone-and-Plate Viscometer in Determining the Rheological Curve of Non-Newtonian Fluids in UV Inks
This article introduces how a cone-plate viscometer measures the rheological curve of UV ink. UV ink is a non-Newtonian fluid whose viscosity changes with shear rate.
Lab Mixer Selection - Viscosity Determines Torque
This article mainly discusses how to select a laboratory mixer based on the viscosity of the material. The higher the viscosity, the greater the torque required. Low-viscosity liquids are suitable for high speed and low torque, while high-viscosity materials require low speed and high torque.
The impact of temperature uniformity in laboratory water baths on viscosity measurement
This article discusses the importance of temperature uniformity in laboratory water baths for viscosity measurement. Viscosity is highly sensitive to temperature variations, and uneven temperature distribution within the water bath can lead to deviations in measurement results.
Guide to Selecting a Laboratory Rotational Viscometer for Coatings Development
This article introduces how to select a laboratory rotational viscometer in coatings research and development. It first explains the principle of rotational viscometers measuring viscosity based on shear resistance, and then points out that key parameters to consider during selection include measurement range, shear rate, temperature control, and rotor configuration.
The Zahn cup is used for the daily inspection of the viscosity of electrophoretic paint bath solutions.
This article introduces the application of the Zahn cup in daily inspections of the viscosity of electrophoretic paint bath solutions. The viscosity of electrophoretic paint affects coating quality, making daily inspections crucial. The Zahn cup is simple to operate, cost-effective, and suitable for rapid on-site measurements.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Handheld viscosity cups are used for rapid assessment of paint viscosity at construction sites.
A handheld viscosity cup is a portable tool used to quickly assess the viscosity of coatings at construction sites. It operates based on the flow-out time method, calculating viscosity by measuring the time it takes for the coating to flow out of the cup's orifice. It is suitable for Newtonian or approximately Newtonian fluids.