Digital-Type Torque Meter

Digital torque wrenches convert applied rotational force into electrical signals via sensors, which are then processed by digital circuits to directly display torque values. They are used to measure the torque of rotating components such as screw fastening and bottle cap sealing, ensuring that tightening forces meet standards in production line quality inspections and equipment maintenance.
Selection
When selecting, consider that the measurement range should cover the actual torque values, the accuracy should meet the process requirements, the sensor size should be compatible with the measured component, and it should have unit switching and data output functions. Environmental factors such as temperature effects need to be verified, and the operation interface should be clear for easy on-site reading.

Terms

Standards

Instruments

Sampling speed up to 1920HZ, accuracy level 0.5, support three units of automatic conversion and a variety of test mode, with data storage and qualified judgment function, suitable for high-speed Impact torque detection.

$ 974.00

With 1 level accuracy and +/- 1% Indication Error, it supports three test modes of real-time torque tracking, peak holding and first peak, and can store 99 sets of data and automatically calculate statistical values.

$ 2026.00

The series micro motor provides 94N.cm large torque output, equipped with multi-stage Non-metallic gear transmission system to ensure stable operation and low noise, supports 100-1400rpm stepless speed regulation and has digital Rotation speed display function.

$ 449.00

Digital control technology implementation of deep closed loop constant speed, low speed to maintain constant Power work; Max. Torque up to 650mNm, can handle viscosity up to 20000mPa · s liquid; support reversal function, speed convenient.

$ 373.00

Adopt digital closed-loop control technology, maintain constant Power operation at low speed, support forward and reverse switching and 0-9999 minute timing function, Max. Torque 1.5Nm, can handle materials with viscosity up to 100000mPa · s.

$ 515.00

Using S-type Sensor structure, Measurement accuracy of +/- 0.5%, with 10 data storage and automatic calculation functions, support for automatic conversion of N/kgf/lbf units, peak hold and automatic release functions can be freely set time.

$ 937.00

Range 20~ 2,000,000 mPa · s, repRoducibility +/- 0.5% F. S, LCD display viscosity, Rotation speed, temperature and torque, easy operation and high accuracy.

$ 595.00

Using S-type external Sensor, Measurement range 10%~ 100% FS, Indication Error less than +/- 0.5%, with peak hold and automatic unit conversion function, support Data storage and sound and light alarm settings.

$ 803.00

The LCD screen visually displays viscosity, Rotation speed, percentiMeter torque and rotor information, with a range of 20~ 2000000 mPa · s, repRoducibility +/- 1% F. S, and supports eight Rotor speed switches.

$ 536.00

Using S-type Sensor structure, Measurement range 10% -100% FS, Indication Error less than +/- 0.5%, with peak hold, automatic alarm and Data storage functions, support Linear dispersion test and machine linkage control.

$ 766.00

Accuracy of +/- 0.5%, sampling speed of 100 times/second, can store 99 sets of data and automatically calculate statistical values, support three unit automatic conversion and peak hold functions.

$ 591.00

Using electronic Sensor technology, sampling speed 100HZ, accuracy up to 1 level, support three units automatic conversion and three test modes, with data storage and upper and lower limit alarm functions.

$ 1306.00

Using series micro motor and multi-stage Non-metallic gear drive, Max. Torque reaches 94N.cm, Speed range 100-1300rpm, supports 15L Processing capacity, low running noise and stable torque output.

$ 380.00

Using series micro motor, output power 300W, Max. Torque 195N.cm, low speed running torque, multi-stage Non-metallic gear transmission force, stable operation and low noise, suitable for a variety of Impeller.

$ 572.00

Sampling speed of 100Hz, accuracy of 0.5, support three units of automatic conversion and a variety of test mode, can store 99 sets of data and automatically calculate statistical values, equipped with PC software for data analytics.

$ 591.00

Articles

How to choose the right rotational viscometer?
This article introduces how to select an appropriate rotational viscometer, so you won't be blind when choosing a viscosity measurement instrument!
Standard Test Method for Measuring Optical Haze of Transparent Coated Films Using a Haze Meter
This article introduces the standard method for measuring the optical haze of transparent coated films using a haze meter. First, the instrument must be calibrated according to the standard, and the sample needs to be conditioned in a constant temperature and humidity environment. The measurement involves four steps, including air zeroing, measuring total transmission and scattered light flux, and finally calculating the haze value.
How to choose a single-column electronic universal testing machine based on the maximum test force
This article introduces how to select a single-column electronic universal testing machine based on the maximum test force. First, determine the strength range according to the material type and standard, such as plastics, metals, etc. Then, calculate the maximum force based on the tensile strength and specimen area, and multiply it by a safety factor of 1.3 to 1.5.
Pencil hardness tester rapidly evaluates scratch resistance of paint film.
This article introduces how to quickly assess the scratch resistance of paint films using a pencil hardness tester. During the test, standard pencils (ranging from 6B to 9H) are used to scratch the coating at a fixed angle and pressure to observe whether scratches occur.
Stormer viscometer controls the in-can viscosity of latex paint.
This paper introduces the application of the Stormer viscometer in controlling the paint can viscosity of latex paint. Paint can viscosity affects application performance and user experience, with either too high or too low values causing issues.
Use of Fluorescence Spectrophotometer in Measuring Excitation and Emission Spectra of Anti-Counterfeiting Fluorescent Inks
This article introduces the application of fluorescence spectrophotometry in the spectral measurement of anti-counterfeiting fluorescent inks, including instrument calibration, sample preparation, and methods for measuring excitation and emission spectra.
Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Application of Cone-and-Plate Viscometer in Determining the Rheological Curve of Non-Newtonian Fluids in UV Inks
This article introduces how a cone-plate viscometer measures the rheological curve of UV ink. UV ink is a non-Newtonian fluid whose viscosity changes with shear rate.
Spectrophotometer measures ink spectral reflectance and opacity.
This article introduces how to measure the hiding power of ink using a spectrophotometer. The instrument irradiates the ink sample, measures its reflectance within the visible light spectrum, and calculates the hiding power using the Kubelka-Munk model.
Impact of the Fixture Design of a Drop Hammer Impact Tester on the Plastic Impact Strength Results
This article primarily discusses the impact of the fixture design of a drop-weight impact testing machine on the results of plastic impact strength tests. The geometric parameters of the fixture, clamping method, and contact surface material can alter the stress state and energy transfer of the specimen, thereby affecting the accuracy of the test data.
Application of Small Push-pull Force Gauge in Rapid Inspection of Adhesive Peel Strength for Mobile Phone Screens
This article introduces how to quickly test the peel strength of adhesive on phone screens using a small push-pull gauge.
Cost-performance analysis of single-channel versus multi-channel switching modules when selecting a laboratory ion meter.
This article compares the cost-effectiveness of single-channel and multi-channel switching modules for laboratory ion meters. Single-channel devices have lower purchase costs, but additional instruments are required for each additional detection parameter. Multi-channel units have higher initial investment, but when testing more than three parameters, the total cost over three years is lower and the sample throughput is greater.
Shore Durometer Selection: Matching Principles of Hardness Models and Measurement Ranges
This article introduces the selection method for Shore durometers, with the core focus on ensuring that the hardness type matches the material's hardness range and rebound characteristics. When selecting, the principle that the measured value falls within 20% to 80% of the full scale should be followed to avoid data distortion.
Turbidity meter selection: Basis for choosing light source type and measurement accuracy.
This article mainly introduces how to select a turbidity meter based on its light source type and measurement accuracy.
Lab Mixer Selection - Viscosity Determines Torque
This article mainly discusses how to select a laboratory mixer based on the viscosity of the material. The higher the viscosity, the greater the torque required. Low-viscosity liquids are suitable for high speed and low torque, while high-viscosity materials require low speed and high torque.