Handheld Whiteness Measurement Device

The handheld whiteness meter illuminates the sample surface with a built-in light source, detects the intensity of reflected light, and calculates the value according to the standard whiteness formula. It is used for quickly assessing the whiteness of materials such as paper and plastics, suitable for production line or on-site inspections, helping to control the consistency of product appearance.
Selection
When selecting a handheld whiteness meter, consider whether the measurement range covers the whiteness values of your samples to ensure compliance with industry standards such as ISO 2470. Pay attention to the instrument's accuracy and repeatability, and choose a portable, durable design that accommodates the size and shape of the samples. Check the ease of calibration and data output functions to meet daily testing requirements.

Terms

Standards

Instruments

Using 45/0 lighting conditions, Repeatability of 0.2, small size and light weight, support fluorescent whiteness measurement, one battery can be used continuously for more than 60 hours, moisture-proof design to adapt to harsh environments.

$ 385.00

Can measure ISO blue light whiteness and fluorescence whiteness, support powder whiteness measurement, Repeatability ≤ 0.02, built-in thermal printer, data can be cached and power-off protection, equipped with RS232 interface for easy communication.

$ 1051.00

Using R457 whiteness formula, blue light whiteness and fluorescence whiteness can be measured simultaneously, Repeatability ≤ 0.3, Operating temperature 5~ 35 ℃, optical path design is simple to ensure measurement accuracy and Repeatability.

$ 432.00

Can measure ISO whiteness and fluorescence whiteness, equipped with diffuse ball diaMeter 150mm, test hole 19mm, support light scattering coefficient, absorption coefficient and other Optical inspection paraMeters, suitable for a variety of material surface whiteness analysis.

$ 1174.00

R457 blue light whiteness formula, Measurement range 0~ 199.9%, resolution 0.1, Basis Weight measurement of whiteness of fluorescent whitening objects and paper Opacity, suitable for a variety of materials surface flat samples.

$ 332.00

Repeatability of 0.2 for measurement of diffuse reflection factor using 457 nm blue wavelength can detect Fluorescent Whitening Agent and calculate fluorescence whiteness value, which is suitable for surface whiteness analysis of various materials.

$ 554.00

Using LED Illuminant and 45/0 illumination conditions, Measurement range 0~ 199.9, resolution 0.1, can detect Fluorescent Whitening Agent and measure increased whiteness, Repeatability ≤ 0.3.

$ 417.00

R457 blue light whiteness formula, Measurement range 0~ 100%, resolution 0.1, Repeatability ≤ 0.3, suitable for fluorescent whitening objects and paper Opacity measurement.

$ 490.00

Using LED Illuminant, 45/0 illumination conditions, Measurement range 0~ 199.9, Repeatability ≤ 0.3, suitable for whiteness measurement of white objects or powders, easy to carry and on-site detection.

$ 393.00

Measurement time is only 1.5 seconds, Repeatability is less than R0.1, which can measure a variety of whiteness indicators and reflectance, and is suitable for the analysis of fluorescent whitening samples.

$ 800.00

Using blue light whiteness R457 standard, Measurement range 0~ 100, Repeatability ≤ 0.5, Basis Weight can reflect fluorescent whitening effect and accurate measurement paper Opacity.

$ 654.00

R457 blue light whiteness measurement, Indication Error +/- 2.5, repeatability error ≤ 0.3, equipped with 10V/30W halogen tungsten lamp light source to ensure stable reflection performance detection.

$ 687.00

Can measure ISO whiteness and fluorescence whiteness, Repeatability ≤ 0.02, support data cache and power-off protection, equipped with RS232 interface for easy communication, suitable for powder and flake samples.

$ 953.00

It can measure the blue light diffuse reflection factor (R457) and fluorescence whiteness, use d/o illumination observation geometry conditions, test hole diaMeter 30mm, can analyze whether the material contains fluorescent whitening agent and measure a variety of Optical inspection coefficients.

$ 1348.00

Adopt LED Illuminant and 45/0 illumination conditions, measurement aperture Φ 15mm, resolution 0.1, Repeatability ≤ 0.3, AC-DC dual-use design is convenient for on-site rapid detection of whiteness value.

$ 233.00

Articles

Paper Whiteness Tester Measures CIE Whiteness
This article explains how a paper whiteness meter measures CIE whiteness. Whiteness is a crucial optical indicator for evaluating paper quality. Traditional methods rely on subjective judgment, while modern instruments provide objective data by simulating standard lighting conditions.
Principle and Application of Whiteness Meter in Measuring Coating Whiteness
A whiteness meter quantifies the whiteness of paint samples by simulating human perception of white, measuring the diffuse reflectance of light—particularly in the blue wavelength range—and converting it into a numerical whiteness value. It employs standardized optical configurations and mathematical models, such as the Ganz formula, to assess the brightness and chromaticity of coatings.
Calibration and Use of Paper Whiteness Tester
This article introduces the working principle, calibration process, operational steps, and factors influencing the measurement results of a paper whiteness tester. The instrument evaluates whiteness by measuring the reflectance of blue light from paper, and calibration requires the use of a standard whiteboard in accordance with relevant standards.
Application of Whiteness Meter in the Evaluation of Paper Brightness and Visual Comfort
The whiteness meter quantifies the brightness and whiteness of paper by measuring its reflected light characteristics, following international standards such as ISO to ensure comparability of results. The brightness of paper affects visual comfort, and moderate whiteness can enhance the reading experience, but excessive whiteness may lead to fatigue.
Whiteness meter measures the whiteness of white pigments
This article introduces the standard method for measuring the whiteness of white pigments using a whiteness meter. Whiteness is an important optical indicator for evaluating the quality of white pigments, and a whiteness meter can provide objective measurements.