Temperature Viscosity Tester

A temperature viscosity tester heats a sample and measures its flow resistance, reflecting changes in the material's viscosity at different temperatures. It is used in industries such as coatings and inks for quality control and process adjustments to ensure product performance remains stable under varying temperature conditions.
Selection
When selecting, consider that the measurement temperature range should cover the actual usage conditions, the viscosity range should match the sample characteristics, and the temperature control accuracy should meet the process requirements. Pay attention to the sensor response speed and material corrosion resistance. The operation interface should be simple, and the supporting software should be capable of recording temperature-viscosity curves. Choose appropriate rotors or measurement cups based on the sample volume.

Terms

Standards

Instruments

The stainless steel sample container is easy to clean, only 16 ml sample volume, Temperature range 0.1 ℃ -100 ℃, L-type Measurement range 0.7-2000 mpas, to achieve accurate viscosity measurement.

$ 2252.00

The equipment integrates viscosity measurement and temperature control, temperature control accuracy +/- 0.1 ℃, supports 2-16ml small sample volume, uses SC4 rotor to provide accurate viscosity data, electric lifting and automatic optimization program to improve operation convenience.

$ 5881.00

The SC4 rotor cylindrical geometry is used to provide accurate viscosity measurement; the sample dosage is only 2-16ml, reducing temperature inhomogeneity; the continuously variable speed and automatic lifting system are supported, and the temperature control accuracy is +/- 0.1 ℃, allowing the user to correct the temperature and viscosity coefficient.

$ 4438.00

Sample dosage only 2-16ml, viscosity range of 50~ 3300000mPa · s, temperature accuracy +/- 0.1 ℃, support stepless speed and automatic lifting, temperature and viscosity coefficient correction, data storage methods are diverse.

$ 5023.00

Using PID intelligent temperature control technology, Precision temperature control up to +/- 0.1 ℃, equipped with 7-inch Touchscreen and four-hole test position, automatically calculate viscosity and store 50 sets of data, easy and efficient operation.

$ 5399.00

Integrated viscosity measurement and temperature control function, using semiconductor temperature control technology implementation +/- 0.1 ℃ accuracy, sample volume only 2-16ml, electric lifting system to ensure accurate positioning, support infinitely variable speed and rheological Linear dispersion programming.

$ 5881.00

Using semiconductor temperature control technology, accuracy of +/- 0.1 ℃, support 2-16ml small sample measurement, SC4 rotor provides accurate viscosity data, electric lifting and automatic temperature optimization program to shorten thermostatic time and improve experimental efficiency.

$ 5881.00

The SC4 rotor structure is used to ensure accurate viscosity measurement, the sample dosage is only 2-16ml, the continuously variable speed and three data storage methods are supported, and the temperature control accuracy is +/- 0.1 ℃.

$ 4438.00

Using semiconductor temperature control technology implementation +/- 0.1 ℃ accuracy, SC4 rotor only needs 2-16ml sample volume to complete accurate viscosity measurement, support infinitely variable speed and automatic lifting system operation is convenient.

$ 5881.00

The small sample adapter only needs 2-16ml sample volume, temperature accuracy of +/- 0.1 ℃, supports stepless speed measurement and automatic lifting system, with viscosity and temperature correction function and a variety of data storage methods.

$ 5023.00

Using SC4 rotor to achieve 5~ 3300000mPa · s viscosity measurement, temperature control accuracy of +/- 0.1 ℃, support continuously variable speed and automatic lifting system, sample thermostatic uniform and easy to clean.

$ 5023.00

With a small sample adapter requiring only 2-16ml sample volume, the SC4 rotor provides accurate viscosity measurement; supports continuously variable speed and +/- 0.1 ° C temperature control accuracy, and electric lift positioning is convenient for cleaning and thermostatic operation.

$ 4438.00

Using a small amount of sample adapter and SC4 rotor, the sample dosage is only 2-16ml, the viscosity range is 100~ 6.6mPa · s, the temperature accuracy is +/- 0.1 ℃, and it supports continuously variable speed and automatic lifting, shortens the thermostatic time and improves the measurement accuracy.

$ 5023.00

Range 20~ 2,000,000 mPa · s, repRoducibility +/- 0.5% F. S, LCD display viscosity, Rotation speed, temperature and torque, easy operation and high accuracy.

$ 595.00

500Ml capacity S6 viscosity standard oil, 20 ℃ viscosity 8.911mPa · s, 25 ℃ viscosity 7.498mPa · s, traceable to national standards, compatible with a variety of test equipment calibrating requirements.

$ 472.00

Articles

Application of Laboratory Scraper Heating Coating Machine in Hot Melt Adhesive Coating
This article introduces the application of a laboratory blade heating coating machine in hot melt adhesive coating. It first explains the coating process and principles, including three stages—heat conduction, fluid shear, and surface wetting—as well as the influence of temperature on adhesive viscosity.
Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
The impact of temperature uniformity in laboratory water baths on viscosity measurement
This article discusses the importance of temperature uniformity in laboratory water baths for viscosity measurement. Viscosity is highly sensitive to temperature variations, and uneven temperature distribution within the water bath can lead to deviations in measurement results.
Guide to Selecting a Laboratory Rotational Viscometer for Coatings Development
This article introduces how to select a laboratory rotational viscometer in coatings research and development. It first explains the principle of rotational viscometers measuring viscosity based on shear resistance, and then points out that key parameters to consider during selection include measurement range, shear rate, temperature control, and rotor configuration.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Temperature-controlled Rotational Viscometer Simulates Coating Rheology in Construction Environments
This article introduces how to use a temperature-controlled rotational viscometer to simulate construction environments in order to study the flow characteristics of coatings. The viscosity of coatings changes under different temperatures and shear conditions, which affects their application performance.
Standard Method for Measuring the Melt Viscosity of Hot Melt Adhesives with a Rotational Viscometer
This article introduces the standard method for measuring the molten viscosity of hot-melt adhesives using a rotational viscometer. During the measurement, the hot-melt adhesive sample must be fully melted and degassed, placed into a measuring cup, and then measured with the rotational viscometer at a set temperature.
Method for measuring ink viscosity with a rotational viscometer
A rotational viscometer measures viscosity by detecting the torque experienced by the rotor as it rotates in the ink, with the calculation formula being η = K × (T/ω). Before measurement, it is necessary to select an appropriate rotor, control the temperature, and calibrate the instrument.
The coating machine in the laboratory ensures a more stable functional layer on the surface of copper and aluminum foils.
The laboratory coating machine is used to apply functional layers on the surfaces of copper foil and aluminum foil. By precisely controlling parameters such as coating speed, slurry viscosity, and drying temperature, it enhances the uniformity and adhesion of the coatings.