Continuous pH Meter

A continuous pH meter forms a galvanic cell through a glass electrode and a reference electrode to measure the potential difference generated by the hydrogen ion concentration in the solution. It monitors changes in acidity and alkalinity during processes, enabling real-time control in applications such as water treatment and chemical reactions.
Selection
When selecting, consider the electrode material's compatibility with the measured medium, the protection level matching the on-site environment, and the temperature compensation range covering the operating conditions. Ensure the output signal is compatible with the existing control system, and the electrode is easy to maintain and clean.

Terms

Standards

Instruments

With PH/ORP measurement function, Measurement accuracy up to +/- 0.02pH, support temperature automatic compensation and manual compensation, provide high and low limit alarm dual relay, isolated transmitter port maximum loop resistance greater than 300Ω.

$ 154.00

Supports 24-hour continuous monitoring of acidity and temperature, Measurement accuracy +/- 0.2pH, resolution 0.1pH, Manual calibration method, suitable for rapid measurement of multiple batches of samples.

$ 328.00

Measurement range pH0.0-14.0, EC0.00-20.00 mS/cm, Automatic calibration and continuous monitoring function, easy and convenient operation.

$ 532.00

Support 0.00-14 pH and 0.00-10 mS/cm conductivity measurement, automatic temperature compensation, 24-hour continuous monitoring, high and low alarm LED indication, Data storage interval of 15 minutes.

$ 769.00

Wall-Mounted waterproof structure is equipped with PTFE anti-clogging dialysis membrane, supports 0.0-14 pH Measurement range and +/- 0.2pH accuracy, alarm point can be set at 3-11pH, LED light reminder when the setting exceeds +/- 0.5pH, extending ElectRode life.

$ 272.00

Measurement range 0-14 pH, temperature resistance 0-100 ° C, side arm construction allows for faster Flow velocity for continuous pH monitoring applications.

$ 649.00

Measurement accuracy of +/- 0.05pH, resolution of 0.01pH, pH and mV can be detected at the same time, built-in battery supports 10-15 hours of battery life, easy to operate, stable and reliable.

$ 127.00

Measurement accuracy of 0.01 pH, support automatic temperature compensation and pH/mV/temperature Multi-ParaMeter measurement, simple, stable and reliable operation.

$ 175.00

Measurement accuracy of +/- 0.02pH, resolution of 0.01pH, support three-point calibrated, built-in Glass electRode, small size weighing only 88g, suitable for 0-50 ℃ environment, easy to quickly detect on site.

$ 104.00

Measurement range 0.00-14 pH, accuracy +/- 0.05pH, with temperature compensation function, portable design for easy field use, large screen LCD display is clear and intuitive.

$ 114.00

Measurement range 0.00-14 pH, accuracy +/- 0.05pH, with automatic temperature compensation function, portable design for on-site fast detection, repeatability error only +/- 0.03.

$ 105.00

Measurement accuracy of +/- 0.1pH with three-point calibrating technology, PH and temperature can be measured simultaneously, compact and portable, suitable for outdoor use.

$ 107.00

Using planar pH ElectRode design, Measurement accuracy of 0.01pH, Support 1-3 point Automatic calibration, with automatic temperature compensation and end point locking function, full waterproof structure to ensure harsh environment use.

$ 178.00

Glass shell and sensitive membrane, pH Measurement range 0-14pH, Temperature range 5-60 ℃, suitable for routine sample measurement, liquid boundary is ceramic core single salt bridge, reference type Ag/AgCl.

$ 98.00

Using external ElectRode design, Measurement accuracy of 0.01pH, support 0.1-14 pH range and 0-50 ℃ temperature measurement, small size for on-site detection and operation.

$ 112.00

Articles

Application of Wet Film Wheel Gauge in Continuous Measurement of Wet Film Thickness for Large-Area Coatings
The wet film wheel gauge is a mechanical tool used to measure the thickness of wet coatings, operating based on the geometric relationship of three coaxial disks (two parallel outer wheels on the sides and an eccentric inner wheel in the middle).
Negative Pressure Method Sealing Tester for Detecting Leakage in Food Packaging
The negative pressure method seal tester creates a pressure difference inside and outside the packaging by evacuating air to detect leaks in food packaging. If there is a leak in the packaging, water will enter the packaging or produce continuous bubbles under the pressure difference, thereby determining the seal integrity. The test requires controlling parameters such as vacuum level and time, and should be conducted in accordance with relevant standards.
Key points for measuring the pH of water-based ink with a pH meter
This article introduces the key steps for measuring the acidity or alkalinity of water-based inks using a pH meter.
Cupping tester evaluates the ductility of coatings.
The cupping tester is a detection device used to evaluate the ductility of coatings under biaxial tension. During the test, the punch presses the sample into the die until the first continuous crack appears in the coating, at which point the penetration depth of the punch is recorded as the cupping depth.
The Role of Roll-to-Roll Coating Machines in Photoresist Coating for Semiconductor Packaging
The roll-to-roll coating machine achieves efficient production through continuous unwinding, coating, and rewinding processes. It utilizes precise coating methods to control the thickness of the adhesive film and is suitable for coating materials such as flexible substrates.
Application of Roll-to-Roll Coating Machines in the Energy Storage Field
A roll-to-roll coating machine is a continuous coating equipment. Its core process involves uniformly applying slurry onto the surface of a flexible substrate (such as metal foil or polymer film), followed by steps like drying and rolling to produce continuous coated materials.
When to use three-point calibration versus two-point calibration for pH meters?
The calibration of a pH meter is performed to determine the actual zero potential and slope of the electrode, enabling accurate measurement of the acidity or alkalinity of a solution. Two-point calibration is commonly used for daily measurements within a narrow range, while three-point calibration is employed for higher accuracy requirements.
How to choose between the rolling ball method and the inclined plate method for initial tack testing instruments
The rolling ball method and the inclined plane method are two commonly used techniques for testing the initial tack of adhesive materials. When selecting an instrument, factors to consider include the material's application scenario (such as adhering to spheres or anti-slip on inclined surfaces), the requirements of industry testing standards, and the data needs (discrete grades or continuous numerical values).
Application of Continuous Coating Machine for Lithium Battery Electrode Preparation in Electrode R&D
The laboratory continuous coater is a key piece of equipment in lithium battery electrode research and development, used to simulate mass production coating processes. By precisely controlling parameters such as coating speed, thickness, and tension, it helps researchers optimize slurry formulations and coating procedures.
Roll-to-roll coater enables continuous preparation of flexible electronic materials.
Roll-to-roll coating is a continuous production process that involves uniformly applying functional slurry onto a flexible substrate, followed by drying and curing to form a functional film.