Paint color matching and measuring instrument.

The paint color matching instrument illuminates the sample with a light source, and the sensor receives the reflected light to analyze color data. It is used to compare color differences during paint formulation, control batch consistency, and is applied in fields such as automotive repair and industrial coating.
Selection
When selecting a paint color matching instrument, consider measurement accuracy and repeatability, ensuring alignment with industry standards such as ASTM. Evaluate the portability of the instrument and the simplicity of its operation interface to ensure compatibility with existing color mixing systems. Additionally, refer to maintenance requirements and the technical support provided by the brand.

Terms

Instruments

In line with the LOVIBOND color scale standard, the sub-field of view Color matching Sensitivity is high, the Measurement range is red 0.1-79, yellow 0.1-79 LOVIBOND units, and the structure is simple and easy to operate.

$ 599.00

Imported matte aluminum reflector to achieve uniform lighting, equipped with six kinds of Illuminants including D65 and UV, table size 700 * 530mm to meet a variety of color requirements.

$ 687.00

Utilizing a full-spectrum LED light source and a spectral sensor with a wavelength range of 400-700nm, it is equipped with a 3.5-inch capacitive touch screen, built-in multiple color cards, achieving a color card matching accuracy of over 90%, and capable of measuring various color parameters.

$ 651.00

Built-in camera to accurately locate the measurement area, UV Illuminant can measure fluorescent color, Repeatability Delta E * ab ≤ 0.06, supports 26 kinds of Illuminant and 30 + kinds of chroma indicators to meet various measurement needs.

$ 1929.00

Provide adjustable illuminance and Color temperature visible light, Color temperature range 2300K-8000K, illuminance up to 3000LX, infrared wavelength 850nm optional, radiation intensity greater than 400uW/CM ², stable light color without stroboscopic, life over 10,000 hours.

$ 5850.00

Using ruby probe and digital Probe technology, Measurement range 0-3500 μm, error ≤ +/- ( 3% H + 2 μm), 0.5 seconds fast measurement, can identify iron powder putty layer and a variety of substrate types.

$ 180.00

Contains 215 Colors, Fan-shaped design is easy to carry, color sample size 2.0x5.0cm, each page displays 5 Colors, bright type, widely used in Coating industry color comparison.

$ 96.00

Transmission surface uniformity of more than 93%, Color temperature adjustment range 2300K-8000K, Illuminance adjustable 0-160,000 Lux, Support Frequency adjustment 1-100KHz, life of more than 10,000 hours, can be connected through RS485 or WIFI computer control.

$ 5366.00

Featuring a 20mm large aperture design, it enables uniform measurement of textured and rough surfaces; repeatability ΔE*ab ≤ 0.03 ensures high precision; equipped with a touchscreen and color card matching for convenient operation, supporting multiple color difference formulas and color spaces.

$ 490.00

Konig and Persoz swing bars are used, Konig swing period is 1.4s, Persoz swing period is 1s, and the number of swing angles is automatically recorded, which is suitable for accurate determination of paint film Hardness.

$ 662.00

With 15 °, 45 °, 110 ° three-angle measurement function, can simultaneously obtain Color data, flicker and particle grade; built-in automatic white calibrating, no human intervention; with stable long-life LED Illuminant, the service life is up to 10 years.

$ 11100.00

Built-in camera to accurately locate the measurement area, equipped with UV Illuminant to achieve fluorescent color measurement, Repeatability Delta E * ab ≤ 0.06, support more than 30 chroma indicators and 26 kinds of Illuminant conditions, Automatic calibration operation is convenient.

$ 1655.00

With three light source system, color rendering index up to 98, all metal structure with three drawer, table size 1350 * 900mm, in line with ISO3664 international standards.

$ 2365.00

Adopt Φ 4mm measurement aperture and full Light spectrum LED Illuminant, chromatic value Repeatability Delta E * ab 0.05, support cloud color database and a variety of Color difference formula calculation, portable design with dust cover and long battery life.

$ 538.00

With a high CRI of 98 and a color temperature of 6500K, it is equipped with a light source Timer and three drawer, and the all-metal construction ensures durability and ease of operation.

$ 2171.00

Articles

Spectrophotometer measures ink spectral reflectance and opacity.
This article introduces how to measure the hiding power of ink using a spectrophotometer. The instrument irradiates the ink sample, measures its reflectance within the visible light spectrum, and calculates the hiding power using the Kubelka-Munk model.
The combination of hiding power chart paper and a spectrophotometer enables the digital evaluation of hiding power.
This article introduces how to combine hiding power cards with spectrophotometers to achieve digital assessment of hiding power.
Colorimeter evaluation of color difference in anodized coloring layers
This article explains how colorimeters are used to evaluate color differences in anodized coloring layers. It describes how colorimeters convert colors into numerical values based on international standards and quantify color variations by calculating the color difference ΔE.
A spectrophotometer uses digital language to describe colors, making color differences impossible to hide.
A spectrophotometer measures the color of an object through spectral analysis, converting reflected light data into spectral curves. It then calculates chromaticity parameters such as L*a*b* based on international standards, achieving a digital representation of color.
How to Interpret Color Difference Lab Values Measured by a Spectrophotometer? Save This Color Difference Judgment Standard Now!
This article explains how spectrophotometers measure and evaluate color differences using the Lab color space. In the Lab values, L represents lightness, while a and b indicate the red-green and yellow-blue color biases. The color difference ΔE is calculated using a formula to quantify the variation between a sample and the standard.