Vertical Nitrogen-Filled Oven

The vertical nitrogen-filled oven creates an inert environment by injecting nitrogen to replace the air inside the chamber, preventing sample oxidation. The heating system provides constant-temperature drying for materials, making it suitable for drying, curing, and solvent removal of oxidation-prone materials. In the coatings and ink industries, it is used for pigment drying, and in the plastics industry, it is applied for polymer heat treatment.
Selection
When selecting, pay attention to the temperature range matching the heat resistance of the material, and the inner liner material must be corrosion-resistant. The nitrogen flow rate should meet the process requirements for oxygen prevention, and temperature control accuracy affects heating uniformity. The chamber structure should accommodate the sample size, with safety devices including over-temperature protection and explosion-proof design. Energy consumption and nitrogen usage are linked to operational costs.

Instruments

Vertical double air duct vertical hot air circulation design, temperature uniformity +/- 1.0 ℃, variable speed fan can adjust the air volume, large screen LCD display, independent temperature limit alarm system to ensure safe operation.

$ 1009.00

Adopt vertical double air duct vertical hot air circulation, Temperature Fluctuation +/- 1.0 ℃, Inner Chamber dimensions 350 × 350 × 350mm, equipped with PID microcomputer intelligent temperature control instrument and adjustable speed fan to ensure uniform and stable temperature.

$ 683.00

Adopt vertical double air duct vertical hot air circulation, temperature control accuracy +/- 1.0 ℃, Temperature resolution 0.1 ℃, with timing and over-temperature alarm function, turbine centrifugal fan blade with bottom drum and bottom heating to ensure Temperature uniformity.

$ 1719.00

Adopt vertical double air duct vertical hot air circulation technology, Temperature Fluctuation +/- 1.0 ℃, studio volume 65L, equipped with turbine centrifugal fan blades and PID intelligent temperature control to ensure uniform temperature distribution and accurate temperature control.

$ 751.00

Vertical double air duct vertical hot air circulation design to ensure uniform temperature distribution, speed control fan can adjust the air volume according to experimental needs, Inner Chamber dimensions 350 × 350 × 350mm, volume 42L, with independent temperature limit alarm system and paraMeter memory function.

$ 925.00

Vertical design with bottom drum and bottom heater, turbine centrifugal fan blade to achieve vertical hot air circulation, Temperature Fluctuation +/- 1.0 ℃, studio volume 125L, PID microcomputer intelligent temperature control to ensure uniform and stable temperature.

$ 958.00

Vertical double air duct vertical hot air circulation design to ensure uniform temperature distribution, Inner Chamber dimensions 310 × 310 × 310mm, variable speed fan can adjust the air volume, large screen LCD display multiple sets of data, with paraMeter memory and over-temperature alarm function.

$ 832.00

Adopt automatic nitrogen measurement distillation system, nitrogen measurement range 0.1-200 mgN, collection rate ≥ 99%, repeability rate < +/- 1% relative to Standard Deviation, semi-automatic working mode, distillation time 5-15 minutes, suitable for a variety of sample analysis.

$ 493.00

Vertical double air duct vertical hot air circulation design, high temperature uniformity, temperature control accuracy of +/- 1.0 ℃, studio volume 30L, equipped with turbine centrifugal fan blades and low noise blower, fan speed regulation, easy operation and maintenance.

$ 603.00

Vertical structure saves space, Vertical hot air circulation ensures Temperature uniformity +/- 3 ℃, Stainless steel workshop is anticorrosive, double-decked tempered Glass observation window is easy to monitor, PID temperature control accuracy of +/- 1.0 ℃.

$ 3301.00

Vertical double air duct vertical hot air circulation to ensure uniform temperature distribution, temperature control accuracy of +/- 1.0 ℃, equipped with large screen LCD display and independent temperature limit alarm system, support 1-9999 minutes timing function, effectively ensure the safe and stable operation of the experiment.

$ 3410.00

Adopt digital microcomputer temperature controller with accuracy of 0.1 ℃, equipped with double-decked tempered Glass observation window and independent temperature limit alarm system. Vertical forced convection design ensures Temperature Uniformity +/- 2.0 ℃, volume 225L to meet a variety of experimental requirements.

$ 804.00

Contains 1 pack of total nitrogen base Reagent, 1 pack of potassium persulfate powder, 25 packs of anti-interference agent and 25 packs of acid Reagent, suitable for DGB-401 instrument, providing complete detection components.

$ 164.00

Using LED @575nm Illuminant and Nessler Measuring method, Measurement range 0.00-3 ppm, accuracy +/- 0.03ppm, suitable for low concentration ammonia nitrogen rapid detection, easy and economical operation.

$ 209.00

Vertical double air duct vertical hot air circulation to ensure temperature uniformity, temperature control accuracy +/- 1.0 ℃, turbine centrifugal fan blades with the bottom drum design, switch fan adjustable to prevent blowing powder items.

$ 912.00