Dyeing Sample Machine

The dyeing sample machine simulates the dyeing process in a sealed container through heating and mechanical stirring, used for color formulation testing and small-batch production verification of materials such as textiles and plastics.
Selection
When selecting a dyeing sample machine, it is essential to consider the sample capacity and material compatibility, ensure that the control accuracy and temperature range meet testing requirements, and verify that the operational safety and maintenance costs are suitable for laboratory conditions.

Terms

Standards

Instruments

The dual-station design can simultaneously carry out two sample tests, the friction speed is 30CPM, the friction hammer load is 200g, and it has the power-off memory function to support dry and wet friction and organic solvent friction test.

$ 1053.00

Using 60cpm Friction Frequency and 9N Friction Load, the specified number of times of friction can be carried out through the friction head of parcel white cotton cloth, and the sample dyeing Stability can be evaluated according to the gray card comparison.

$ 524.00

Using reciprocating friction method, friction load 9N, Frequency 60cpm, can be set 0~ 999900 times test, support drying wet white cotton cloth for dyeing fastness evaluation.

$ 1413.00

Only 5-18ml sample volume is required to complete the test, the sample cartridge is easy to clean and load, and the 316L material measuringflask can be customized for easy observation and detailed analysis of fluid characteristics.

$ 787.00

The adapter only needs 10-20mL sample volume, equipped with 21, 27, 28, 29 rotors, easy to disassemble and clean, can be connected to Thermostatic Bath to achieve temperature control, expand the viscosity measurement range.

$ 470.00

The coaxial cylinder structure is used to achieve accurate viscosity measurement. The sample dosage is only 10-20mL. It is equipped with a removable sample Cup for easy replacement and cleaning. It supports a variety of rotor models to cover a wide range of viscosity.

$ 317.00

Using coaxial cylinder structure, the sample volume is only 7-13ml, the Measurement accuracy is +/- 2%, equipped with timing function and RS232 interface, suitable for small sample testing.

$ 1153.00

Real-time monitoring of sample temperature, temperature range 0 ℃~ 100 ℃, accuracy +/- 1.0 ℃, can be used with a variety of Viscometers.

$ 119.00

Using coaxial cylinder structure with a small number of sample adapters, only 7.8-11 ml sample volume, Measurement accuracy +/- 2%, equipped with dual RS232 interfaces to directly connect printers and computers.

$ 1038.00

With a small sample adapter requiring only 2-16ml sample volume, the SC4 rotor provides accurate viscosity measurement; supports continuously variable speed and +/- 0.1 ° C temperature control accuracy, and electric lift positioning is convenient for cleaning and thermostatic operation.

$ 4438.00

The small sample adapter only needs 2-16ml sample volume, temperature accuracy of +/- 0.1 ℃, supports stepless speed measurement and automatic lifting system, with viscosity and temperature correction function and a variety of data storage methods.

$ 5023.00

Using coaxial cylinder structure with a small number of sample adapters, the sample volume is only 7.8-11 ml, Measurement accuracy +/- 2%, equipped with dual RS232 interface can be directly connected to the printer and computer for data output.

$ 1077.00

Support 10-20mL small sample testing, viscosity range 80-40000000mPa · s, equipped with a dedicated rotor for High Accuracy measurement, Thermostatic Bath connection can control the sample temperature.

$ 1732.00

Using a small amount of sample adapter and SC4 rotor, the sample dosage is only 2-16ml, the viscosity range is 100~ 6.6mPa · s, the temperature accuracy is +/- 0.1 ℃, and it supports continuously variable speed and automatic lifting, shortens the thermostatic time and improves the measurement accuracy.

$ 5023.00

Shear rate 7.5N, sample volume only 0.5ml, suitable for NTV-CAP1 host, suitable for small sample viscosity measurement.

$ 683.00

Articles

Application of Flexographic Proofing Press in Evaluating Color Reproducibility of Flexographic Inks
This article primarily discusses the use of a flexographic proofer to evaluate the color reproducibility of flexographic inks. It introduces the role of the proofer in simulating production conditions and explains how to prepare samples by setting parameters such as pressure, speed, and anilox roll specifications.
The use of gravure proofing machines in the comprehensive evaluation of gravure ink printability and drying performance.
This article explores how a gravure proofing press can be used to comprehensively evaluate the printability and drying properties of gravure inks. The experiment tested the dot sharpness, transfer rate, and leveling properties of different inks using standard equipment, while recording drying times through the filter paper method and infrared temperature measurement.
Ink proofer simulates printing effects for auxiliary detection.
The ink proofer simulates actual printing conditions such as pressure and speed to produce standard proof sheets, which assist in evaluating printing quality. It precisely controls parameters to ensure high consistency between the proof sheets and the actual printed materials.
Selection Comparison between Automatic and Manual Proofing Methods for Ink Proofing Machines
This article compares manual and automatic proofing methods for ink proofing machines. Manual proofing relies on the operator's experience, offering flexibility and lower initial costs, but it suffers from poor consistency, making it suitable for research and development or low-frequency usage.
The ink proofing machine's color development and ink distribution pressure are not set correctly, making the printed sample sheets unacceptable.
The ink proofer is crucial in printing quality control, as it ensures the even distribution of ink on materials by adjusting pressure. If the pressure is not properly calibrated, the proof may exhibit issues such as uneven color and inconsistent ink layer thickness, rendering it unsuitable as a reference for printing.