The dual-station design can simultaneously carry out two sample tests, the friction speed is 30CPM, the friction hammer load is 200g, and it has the power-off memory function to support dry and wet friction and organic solvent friction test.
Using 60cpm Friction Frequency and 9N Friction Load, the specified number of times of friction can be carried out through the friction head of parcel white cotton cloth, and the sample dyeing Stability can be evaluated according to the gray card comparison.
Using reciprocating friction method, friction load 9N, Frequency 60cpm, can be set 0~ 999900 times test, support drying wet white cotton cloth for dyeing fastness evaluation.
Only 5-18ml sample volume is required to complete the test, the sample cartridge is easy to clean and load, and the 316L material measuringflask can be customized for easy observation and detailed analysis of fluid characteristics.
The adapter only needs 10-20mL sample volume, equipped with 21, 27, 28, 29 rotors, easy to disassemble and clean, can be connected to Thermostatic Bath to achieve temperature control, expand the viscosity measurement range.
The coaxial cylinder structure is used to achieve accurate viscosity measurement. The sample dosage is only 10-20mL. It is equipped with a removable sample Cup for easy replacement and cleaning. It supports a variety of rotor models to cover a wide range of viscosity.
Using coaxial cylinder structure, the sample volume is only 7-13ml, the Measurement accuracy is +/- 2%, equipped with timing function and RS232 interface, suitable for small sample testing.
Real-time monitoring of sample temperature, temperature range 0 ℃~ 100 ℃, accuracy +/- 1.0 ℃, can be used with a variety of Viscometers.
Using coaxial cylinder structure with a small number of sample adapters, only 7.8-11 ml sample volume, Measurement accuracy +/- 2%, equipped with dual RS232 interfaces to directly connect printers and computers.
With a small sample adapter requiring only 2-16ml sample volume, the SC4 rotor provides accurate viscosity measurement; supports continuously variable speed and +/- 0.1 ° C temperature control accuracy, and electric lift positioning is convenient for cleaning and thermostatic operation.
The small sample adapter only needs 2-16ml sample volume, temperature accuracy of +/- 0.1 ℃, supports stepless speed measurement and automatic lifting system, with viscosity and temperature correction function and a variety of data storage methods.
Using coaxial cylinder structure with a small number of sample adapters, the sample volume is only 7.8-11 ml, Measurement accuracy +/- 2%, equipped with dual RS232 interface can be directly connected to the printer and computer for data output.
Support 10-20mL small sample testing, viscosity range 80-40000000mPa · s, equipped with a dedicated rotor for High Accuracy measurement, Thermostatic Bath connection can control the sample temperature.
Using a small amount of sample adapter and SC4 rotor, the sample dosage is only 2-16ml, the viscosity range is 100~ 6.6mPa · s, the temperature accuracy is +/- 0.1 ℃, and it supports continuously variable speed and automatic lifting, shortens the thermostatic time and improves the measurement accuracy.
Shear rate 7.5N, sample volume only 0.5ml, suitable for NTV-CAP1 host, suitable for small sample viscosity measurement.