Adopting the principle of vertical drop of steel balls, the diaMeter of steel balls is 8mm, and the distance between upper and lower grooves is 250mm, which is suitable for the viscosity measurement of high viscosity transparent liquids.
Adopting the principle of rolling timing of the ball by inclined columnar measurement tube, the viscosity range 0.5-1000 00mPa · s, Temperature range -20 ℃ to 120 ℃, Repeatability is better than 0.5%, and the sample sealing measurement has no external interference.
Adapted diaMeter 16mm formed Metering Rod, the total length of 2000mm, through the special structure to correct the straightness of the Rod body, to ensure stable rotation and full contact with the substrate, improve the thickness control accuracy of Spreader.
Equipped with 7-inch Touchscreen, easy to operate, support stepless speed measurement and viscosity automatic conversion, measurement range 1~ 75000000mPa.s, gigabit network port to ensure fast and reliable data transmission.
Wet film thickness 22.9 microns, diaMeter 9.52 mm, the forming Rod uses an extrusion process to process continuous grooves, with no wire breakage and easy cleaning; the wire-wound Rod is based on the traditional principle, and there are differences in coating amount.
The shear rate is 5.0N, the sample volume is only 170μL, the applicable viscosity range is 50~ 100000mPa · s, suitable for a variety of fluid measurement, high measurement accuracy.
Equipped with 7-inch Touchscreen operation interface, supports high-speed data transmission of gigabit network port, measurement accuracy of +/- 2%, temperature control accuracy +/- 0.1 ℃, with automatic lifting and anti-static design.
The shear rate is 13.3N, the sample volume is only 67 μL, the applicable viscosity range is 20~ 37500mPa · s, and the accuracy is +/- 2% F. S, which is suitable for a variety of fluid tests.
The shear rate is 13.3N, the sample volume is only 38μL, the applicable viscosity range is 37~ 75000mPa · s, and the accuracy is +/- 2% F. S, which is suitable for testing various fluid samples.
The shear rate is 3.3N, the sample volume is only 30μL, and the viscosity range is 750~ 1500000mPa · s, which is suitable for accurate measurement of medium viscosity to high viscosity fluids.
The rotor shear rate is 3.3N, the sample volume is only 67 μL, the applicable viscosity range is 300~ 600000mPa · s, and the accuracy is +/- 2% F. S, which is suitable for a variety of fluid testing needs.
The shear rate is 3.3N, the sample volume is 134μL, the applicable viscosity range is 150~ 300000mPa · s, and the measurement accuracy is +/- 2% F. S, which is suitable for testing various fluid samples.
The rotor shear rate is 2.0N, the sample volume is only 100 μL, the applicable viscosity range is 500~ 1000000mPa · s, the accuracy is +/- 2% F. S, suitable for processing a variety of fluid samples.
The shear rate is 13.3N, the sample volume is 24μL, the applicable viscosity range is 75~ 150000mPa · s, the measurement accuracy is +/- 2% F. S, and it is suitable for a variety of fluid tests.
Shear rate 2.0N, sample volume 1700μL, applicable viscosity range 32-63000mPa · s, accuracy +/- 2% F. S, suitable for a variety of fluid measurement.