CIE Color Assessment Cabinet

The CIE standard light box simulates standard lighting conditions such as daylight and fluorescent light to provide a stable and uniform lighting environment. It is used for visual color comparison of coatings and ink samples, ensuring consistency in color evaluation under different light sources. This equipment is applied in quality control across industries such as printing and plastics.
Selection
When selecting, consider that the light source types should cover commonly used standards such as D65 and TL84. The illuminance uniformity should exceed 85%, and the cabinet size should be suitable for the sample dimensions. The inner walls should be neutral gray to avoid interference, and the lamp lifespan and ease of replacement should align with the frequency of daily use.

Terms

Standards

Instruments

Equipment provides a variety of standard illuminant options, maximum support three Illuminant, high CRI = 98, with Illuminant Timer, uniform lighting, easy to operate, suitable for Color Comparison.

$ 848.00

With a standard 45 degree tilt angle, the same as the light box base color does not interfere with the viewing effect, Dimension 395 * 350mm, weight 1.2Kg, flexible placement and easy to disassemble and transport.

$ 106.00

Configuration of 6 Standard light sources including D65 and UV Illuminant, equipped with 45 degree observation station to achieve 45/0 observation conditions, no need to warm up without flashing, high luminous efficiency Color evaluation fast and reliable.

$ 1171.00

In line with ISO3664 international standards, color rendering index of 98, support multi-light source switching, all-metal structure to ensure stability and durability, inclined table in line with visual observation habits.

$ 1913.00

Color temperature adjustment range 2300K-8000K, illumination adjustment range 0-4000Lux, built-in mobile slide can move the camera front and rear, light source light board can swirl/spin to adjust the angle, provide a uniform lighting environment.

$ 5366.00

Standard light source without preheating, can automatically switch and record the use of time, the use of composite engineering plastic baseplate to ensure ten years without yellowing, support Metamerism detection function.

$ 396.00

With illumination adjustment function, support D65 Illuminant to meet CIE Class A Light spectrum matching, no need to warm up and no flicker, equipped with 45 degree observation station to achieve 45/0 observation conditions, suitable for large items Colorimetric.

$ 4237.00

With high color rendering index CRI = 98 and dual light source design, it provides a variety of color temperature options such as D65, D50, TL84, etc. With light source Timer, uniform lighting and convenient lamp replacement.

$ 783.00

The color temperature of the D65 light source is 6500K, the color rendering index is as high as 98, and the all-metal structure is sturdy and durable. The inclined surface of the operating table conforms to visual observation habits, and the light is uniform and stable.

$ 1735.00

Adopt D65 light source in line with ISO3664 international standards, color rendering index up to 98, equipped with 36W lamp and light source Timer, all-metal structure to ensure stability and durability, inclined table in line with visual observation habits.

$ 1655.00

Light spectrum LED light source, support sample surface free positioning measurement, repeability accuracy ≤ E * ab ≤ 0.07, Measurement speed of only 1.0 seconds, lightweight and portable.

$ 2623.00

Double light source in line with ISO3664 international standards, color rendering index up to 98, with light source Timer, all-metal structure, large folio size easy to operate, accurate proofreading Color deviation.

$ 1784.00

The imported cold light source does not need to be preheated for 100,000 hours, the minimum display value is 0.001mg/L, supports standard measurement and continuous measurement modes, and the built-in large-capacity lithium battery realizes long standby, which can store 4000 sets of measurement data.

$ 816.00

Adopt all-metal sheet metal bracket structure, equipped with 36W × 4 reflection lamps and 36W × 4 transmission lamps, color rendering index CRI ≥ 95, tempered Glass and acrylic uniform plate make the light uniform and not dazzling, with rollers and adjustable support feet.

$ 1639.00

All-metal structure, equipped with 4 18W imported Graphica lamps, color rendering index up to 95 or more, high light uniformity, with Illuminant Timing function.

$ 538.00

Articles

Light source configuration and color matching environment requirements in the selection of standard light boxes
This article discusses how to choose a standard light booth, focusing mainly on the light source configuration and observation environment.
The necessity of a standard light source box in visual color comparison and color difference assessment of coatings.
In the production of coatings, accurate color evaluation is crucial. Visual color comparison is easily affected by light, as natural light is unstable, and different lighting conditions can make colors appear different.
Paper Whiteness Tester Measures CIE Whiteness
This article explains how a paper whiteness meter measures CIE whiteness. Whiteness is a crucial optical indicator for evaluating paper quality. Traditional methods rely on subjective judgment, while modern instruments provide objective data by simulating standard lighting conditions.
Application of Colorimeters in Controlling Color Differences in Paint Batches
This article introduces the role of colorimeters in controlling color consistency in paint production. Since human judgment of color is easily influenced by lighting and subjective factors, colorimeters quantify color differences in the CIELAB color space by measuring spectral data, providing an objective basis for production.
Determination of Chromaticity Value of Pulp by Spectrophotometry
This article introduces the method for determining pulp chromaticity using spectrophotometry. It first explains the importance of chromaticity for pulp quality, then details the basic principles of spectrophotometry, which quantifies color by measuring the reflection of light from the pulp, typically expressed using the CIELAB color system.