Supporting D-type Shore DuroMeter, applying 5kg test force by weight, equipped with Glass bench and adjusting nut to ensure full contact with the sample and improve measurement Stability.
Double pointer design for easy reading, Pin Travel 0~ 2.5mm, Measurement range 0~ 100HD, error +/- 1HD, lightweight and portable only 0.16kg, suitable for on-site Hardness detection.
Can be used with A type or C type Shore DuroMeter, fixed load weight mass 0.75 +/- 0.05kg, hardness Gauge clamping Rod connection size M7x0.5mm, improve hardness testing accuracy and Stability.
Tempered Glass platform, long-term use is not easy to abrasion and rust; the level of the working platform is adjustable, and the hardness Gauge is adjusted to the same level; the weight is accurate, the column lifting space is ≤ 140mm, Dimension 165 * 145 * 380mm.
The device adopts D-type Impact device, supports 360 ° measurement, can display a variety of Hardness standards, has 600 sets of Data storage capacity, is small in size and weighs only 0.2kg, and has a standby time of 100 hours. It is suitable for small spaces and field environments.
Pressure is applied to the hardness Gauge by weight, with a total mass of about 5kg and a pressing speed of 3.2mm/s to ensure test Stability and High Precision, suitable for standard specimen adjustment.
Pin Travel 0-2.5 mm, Measurement range 20-90HD, error +/- 1HD, weight only 0.16kg easy to carry, can be used with racks or handheld to meet different testing needs.
Measurement range 0~ 100HD, error ≤ +/- 1HD, with automatic shutdown, MAX Maximum latch, average calculation function, optional test bench to improve accuracy.
Adopt High Accuracy D-type Impact device, can measure 7 kinds of Hardness values and automatically convert, store 600 sets of data, work for 200 hours on a single charge, support any direction measurement, error +/- 6HLD.
Resolution 0.1H, Accuracy ≤ 1H, Measurement range 10~ 90 HA/HD; Integrated design is lightweight, supports male/imperial conversion, average calculation and a variety of data output methods.
Measurement range > 90C to < 20D, with MAX Maximum latch, automatic shutdown and data output functions, error ≤ 1H, support male/imperial unit conversion.
Equipped with a 1kg fixed load weight, pressing the specimen at a speed of 3.2mm/s, providing stability testing conditions, suitable for standard Hardness measurement, preventing vibration from affecting the results.
Measurement range greater than 90A, resolution up to 0.1H, with MAX Maximum latch and automatic shutdown function, support USB and Bluetooth data output, to meet a variety of hardness of materials testing needs.
Measurement range 0-100HD, recommended to use 20-90HD range, pressing needle stroke 2.5mm, pressing head SR0.1mm, can cooperate with the test rack to improve Measurement accuracy.
Measurement range greater than 90A, error ≤ +/- 1H, with average value calculation and MAX Maximum latch function, support USB, RS-232 and Bluetooth Data output methods.