Built-in Wine pH ElectRode with CPS technology, Measurement range 0.00~ 12.00pH, accuracy +/- 0.05pH@25 ° C. Compact design weighs only 46g, CR2032 battery provides 1000 hours of battery life, suitable for rapid on-site inspection.
Capacity 500mL, calibrated value 6.86pH, with tamper-proof sealing settings to ensure standard liquid mass and freshness, unopened valid period of up to 5 years, suitable for chemical and biological laboratories.
Using microprocessor control, pH Measurement accuracy of +/- 0.02pH, support three point calibrated (4.01, 6.86, 9.18), simple operation, stable and reliable performance.
Microprocessor controlled, with 0.1-14 pH Measurement range and +/- 0.1 pH accuracy, support for three-point calibrate and temperature compensation, portable design weighing only 88g, suitable for on-site rapid detection.
The piercing design can directly measure semi-solid substances, with an accuracy of +/- 0.05PH, equipped with temperature compensation function, Operating temperature range 0-60 ℃, easy to quickly detect on site.
Calibrated at 1.68pH with a capacity of 500mL, with high Precision, for calibrating pH measuring instruments, ensuring reliable results, stored in a drying cool environment to maintain Stability.
Imported high-quality integrated components, microprocessor control to ensure stable performance. Measurement accuracy of +/- 0.05pH, resolution 0.01pH, input Impedance greater than 1 × 10 ² ² Ω, support manual temperature compensation and ElectRode slope compensation function.
Measurement accuracy of +/- 0.05pH, resolution of 0.01pH, pH and mV can be detected at the same time, built-in battery supports 10-15 hours of battery life, easy to operate, stable and reliable.
Impedance input controller, equipped with two-stage signal amplifier, Measurement accuracy of +/- 0.01pH, support for external brands of ElectRode, suitable for harsh industrial environments.
With 0.01 pH Accuracy and +/- 0.2 ° C temperature accuracy, support automatic temperature compensation and ElectRode diagnostic functions, Data storage 450 sets and can be output through U disk.
Using film lamination process, with solvent resistance and chemical resistance, paper Film thickness 0.29mm, Laminating to ensure uniformity of Spreader, with annotation section for easy recording of test information.
Adapted to BNC interface pH ElectRode, supports 0.0-14 pH range calibrate, adjustable dose relay configuration is higher or lower than the user set point dosing, with timeout dosing protection function, the delay time is adjustable by 5-30 minutes.
Measurement accuracy of 0.01 pH, support automatic temperature compensation and pH/mV/temperature Multi-ParaMeter measurement, simple, stable and reliable operation.
Measurement accuracy of +/- 0.02pH, resolution of 0.01pH, support three-point calibrated, built-in Glass electRode, small size weighing only 88g, suitable for 0-50 ℃ environment, easy to quickly detect on site.
Measurement range 0.00-14 pH, accuracy +/- 0.05pH, with temperature compensation function, portable design for easy field use, large screen LCD display is clear and intuitive.