Cyclic Electric Heating Drying Oven

The cyclic electric drying oven heats through electric heating elements and uses a fan to force air circulation, ensuring uniform temperature inside the chamber. It is used to remove moisture from samples or cure materials and is commonly applied in laboratory drying, material heat treatment, and other scenarios.
Selection
When selecting, consider that the temperature range should cover experimental needs, the chamber size should match the sample volume, temperature control accuracy must meet standards, material corrosion resistance should suit the environment, fan noise should not affect work, and energy consumption should align with usage frequency.

Terms

Standards

Instruments

Temperature range RT + 10~ 300 ℃, Temperature Fluctuation +/- 1 ℃, stainless steel liner corrosion resistance, electric heating tube heating fast and uniform, intelligent digital display easy to operate.

$ 403.00

Far infrared radiation heating technology, temperature control accuracy +/- 2 ℃, equipped with thermistor control thermoMeter, rapid low consumption drying, Inner Chamber dimensions 320 * 380 * 320mm.

$ 391.00

Far infrared radiation heating technology, Temperature range RT +~ 300 ℃, temperature fluctuation +/- 2 ℃, equipped with thermistor control thermoMeter, with fast, low consumption, easy adjustment and other advantages, suitable for drying a variety of samples.

$ 465.00

Far infrared radiation heating technology, equipped with thermistor control thermoMeter, Temperature range RT +~ 300 ℃, Temperature Fluctuation +/- 2 ℃, with fast drying and low energy consumption characteristics, suitable for a variety of Sample Handling.

$ 586.00

Microcomputer P.I.D temperature controller, temperature control accuracy +/- 1.0 ℃, volume 136L, with hot air circulation system to improve Temperature Uniformity, support independent temperature limit alarm and optional programming function.

$ 749.00

Temperature control accuracy of +/- 1 ℃, equipped with intelligent digital display and observation window, Inner Chamber dimensions 350 * 450 * 450mm, electric heating tube heating to ensure uniform and stable temperature.

$ 393.00

Temperature control accuracy of +/- 1.0 ℃, temperature resolution of 0.1 ℃, equipped with double-decked tempered Glass observation window and quick-release bottom heating hood, easy to clean and maintain, two heating power to meet different temperature needs.

$ 590.00

Infrared heat source for fast drying, Power 550W, metal material to ensure durability, built-in heating element to pRoduce uniform heat cycle, effective evaporation of water, suitable for drying various materials.

$ 159.00

Far infrared radiation heating technology, Temperature range RT +~ 300 ℃, Temperature Fluctuation +/- 2 ℃, equipped with thermistor control thermoMeter, rapid low consumption drying, suitable for a variety of Sample Handling.

$ 1009.00

Far infrared radiation heating technology, Temperature range RT +~ 300 ℃, Temperature Fluctuation +/- 2 ℃, equipped with stainless steel liner, rapid and uniform heating, suitable for drying a variety of samples.

$ 690.00

Using infrared radiation heating, fine grinding mirror drying surface, heating power 2.0KW, maximum temperature 180 ℃, drying size 600mm × 350mm, to ensure uniform drying and smooth surface.

$ 2462.00

Far infrared radiation heating technology, Temperature range RT +~ 300 ℃, Temperature Fluctuation +/- 2 ℃, equipped with thermistor control thermoMeter, automatic thermostatic control, fast drying and low energy consumption.

$ 883.00

Temperature range RT + 10~ 300 ℃, Temperature Fluctuation +/- 1 ℃, equipped with stainless steel liner and intelligent digital display to ensure uniform heating and long-term durability.

$ 557.00

Temperature range RT + 10~ 300 ℃, Temperature Fluctuation +/- 1 ℃, equipped with intelligent digital display and observation window, uniform and stable heating, suitable for a variety of material drying needs.

$ 356.00

Equipped with PID microcomputer intelligent temperature control system, Temperature Fluctuation +/- 1 ℃, temperature resolution 0.1 ℃; The studio is made of mirror stainless steel, Shelf spacing is adjustable, and the bottom heating hood quick-release structure is easy to clean.

$ 780.00

Articles

Application of High-Frequency Fatigue Testing Machine in Infinite Life Testing of Valve Springs
This article discusses the application of high-frequency fatigue testing machines in the infinite life testing of valve springs. The test simulates the long-term working stress of the spring through high-frequency cyclic loading, with parameters such as preload, amplitude, and cycle count set according to international standards.
Constant temperature bath selection: circulation method and temperature control range.
This article on thermostatic bath selection primarily analyzes two core factors: circulation mode and temperature control range. The circulation mode is divided into natural convection and forced circulation, where the former is suitable for simple static experiments, while the latter offers higher precision and is better suited for multiple samples or integration with external devices.
Laboratory Drying Oven Model Selection - Difference Between Forced Air Convection and Non-Forced Air Convection
This article on the selection of laboratory drying ovens primarily introduces the differences between forced convection (air-blowing) and natural convection (non-air-blowing) drying ovens.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Temperature Oscillation Suppression in Reflux Synthesis Using Laboratory Stirring Heating Mantles
This article explores the causes and suppression methods of temperature oscillations in laboratory heating mantles during reflux synthesis.
The Impact of Cooling Circulating Water Chillers on the Temperature Stability of Digesters
The cooling circulator helps maintain a stable temperature for the digester by circulating the cooling medium, thereby improving the repeatability of experiments. Its working principle involves using a refrigeration system to lower the water temperature, and then circulating the cooled water to the digester through a circulation pump to absorb excess heat.
Effect of Rapid Temperature Change Aging Chamber on Thermal Cycling of Composite Materials
This article primarily explores how rapid thermal cycling chambers affect the performance of composite materials during thermal cycling. It explains that thermal cycling can induce internal stresses in composite materials due to differences in the thermal expansion coefficients of their components, potentially leading to microcracks or performance degradation.
Salt spray aging test chamber for cyclic corrosion evaluation of coating weatherability.
This article introduces the method of using a salt spray aging test chamber to conduct cyclic corrosion tests for evaluating the weather resistance of coatings.
Safety Considerations for Selecting Explosion-Proof vs. Ordinary Drying Ovens in Paint Laboratories
When selecting a drying oven in a paint laboratory, the type should be determined based on the safety risks of the samples and the environment.
Tensile testing machine measures the bending fatigue life of flexible OLED films.
This article introduces a method for testing the bending fatigue life of flexible OLED films using a tensile testing machine. The test simulates repeated bending to evaluate the accumulation of damage in the film under cyclic stress, and monitors performance changes to determine the failure point.
Fatigue testing machine evaluates the long-term durability of resin-based composite materials.
The fatigue testing machine is a key piece of equipment for evaluating the long-term durability of resin-based composite materials. These materials are widely used in fields such as aerospace, but their performance gradually degrades under cyclic loading.
The Taber Abraser evaluates the wear resistance of coatings.
The Taber abrasion tester simulates surface wear of materials through rotational friction, used to evaluate the wear resistance of coatings. During testing, a grinding wheel is used to rub the specimen under a fixed load, and performance is quantified by measuring mass loss or thickness changes after a specified number of cycles.
Determination of dry matter content in pulp using an electric thermostatic drying oven.
This article introduces the method for determining the dry matter content of pulp using an electric thermostatic drying oven. Dry matter content is a key indicator for evaluating pulp quality. The principle of determination involves evaporating the moisture in the pulp through heating and calculating the content based on the mass difference before and after drying.
UV aging test machine evaluates the UV resistance of ink.
This article introduces how to test the UV resistance of ink using a UV aging test chamber. The equipment accelerates aging by simulating ultraviolet light and controlling temperature and humidity, with key testing conditions including temperature, irradiance, and cycle time.