Doctor Blade Rod Coating Machine

The wire-wound rod Coater forms a uniform wet film by rolling a cylindrical rod over the substrate surface. The wire wound around the rod controls the coating thickness and is used for preparing test samples in the laboratory. It is suitable for testing properties such as hiding power and adhesion of coatings and inks.
Selection
When selecting, consider the substrate type and size to match the coating width. Choose the appropriate wire-wound rod diameter based on the viscosity range, as the coating thickness is calculated from the rod diameter. Pay attention to the corrosion resistance of the rod material and the operational stability of the machine. Select either a manual or automatic model according to the budget.

Terms

Standards

Instruments

Using Metering Rod & doctor blade double Spreader mode, Spreader accuracy up to +/- 0.001mm, Spreader rate 5~ 200mm/s adjustable, fixed substrate by vacuum adsorption to ensure film uniformity and repRoducibility.

$ 2736.00

Spreader speed 5~ 180mm/s, Spreader area 400 * 300mm, using Metering Rod & doctor blade and vacuum adsorption system to ensure Spreader uniformity and Stability, can be customized automatic inking function.

$ 9755.00

Using Metering Rod & doctor blade dual Spreader method, Spreader accuracy is up to +/- 10μm, Film thickness range is 0-5000μm. Spreader rate and stroke are controlled by vacuum adsorption to fix the substrate, and the touch screen can effectively improve film repRoducibility and conformity.

$ 3462.00

Spreader speed 5-180mm/s adjustable, wire Rod Spreader accuracy +/- 0.001mm, using touch screen control and mechanical fixture to ensure stable and reliable Spreader process.

$ 2010.00

Utilizing a dual coating method with wire rod and doctor blade, the coating speed is adjustable from 1 to 300 mm/s with stepless speed control, ensuring high precision in film thickness control. Equipped with vacuum adsorption and heating functions, the temperature uniformity reaches ±1°C. The flip-top design facilitates easy cleaning.

$ 24279.00

Spreader accuracy of +/- 0.003mm, Film thickness range of 0~ 10mm, equipped with automatic feeding system and vacuum adsorption, to achieve stable Spreader and efficient operation.

$ 8949.00

Spreader accuracy of +/- 0.001mm and +/- 0.003mm respectively, support 5~ 200mm/s stepless speed change and vacuum adsorption fixation, improve coating conformity.

$ 7141.00

Spreader speed 5~ 200mm/s continuously variable speed, scraper Spreader accuracy +/- 0.003mm, support heating temperature RT +~ 180 ℃, baseplate heating method to ensure stable Spreader effect, improve experimental conformity.

$ 7658.00

With meyer Rod coating accuracy +/- 0.001mm and Blade Coating accuracy +/- 0.003mm, support Vacuum chuck and fixture fixing, coating table size 1440 * 1030mm, clamshell design is easy to clean.

$ 19438.00

Equipped with dual coating methods of wire rod and blade, with an infinitely adjustable coating speed of 1–300 mm/s, wire rod accuracy of ±0.001 mm, blade accuracy of ±0.003 mm, and optional heating and vacuum adsorption functions to meet coating requirements of various thicknesses.

$ 9433.00

Using the formed pRoduction process, Coating Weight is about twice that of the wire-wound coating Rod, wet film thickness is 13μm, film accuracy reaches 0.5 μm, and the material is 304 stainless steel.

$ 120.00

Bar and drawdown blade double coating method, coating speed 1-300mm/s stepless speed regulation, meyer Rod coating accuracy +/- 0.001mm, clamshell drawdown blade design is easy to clean, Touchscreen control operation is simple.

$ 2494.00

Using meyer Rod coating accuracy +/- 0.001mm and Blade Coating accuracy +/- 0.003mm, clamshell Drawdown blade is easy to clean, coating speed 1~ 300mm/s stepless speed regulation, suitable for a variety of substrate uniform Spreader.

$ 5237.00

Using meyer Rod coating accuracy +/- 0.001mm and Blade Coating accuracy +/- 0.003mm, clamshell drawdown blade design is easy to clean, coating speed 1~ 300mm/s stepless speed regulation, suitable for coating of various materials.

$ 11046.00

Drawdown blade and bar coating methods, coating speed 1-300mm/s stepless speed, meyer Rod coating accuracy +/- 0.001mm, clamshell Drawdown blade design for easy cleaning, Vacuum chuck for soft substrates.

$ 6851.00

Articles

How to choose a laboratory coater? Which one should you buy: wire bar, scraper, or slot die?
This article introduces three methods for selecting laboratory coating machines: wire bar coating is suitable for low-viscosity coatings, offering low cost and simple operation; blade coating is ideal for medium-to-high viscosity slurries or those containing particles, with a wide range of film thickness control; slot-die coating provides the highest precision and is suitable for high-end applications such as electronic films.
Comparison of Coating Accuracy between Laboratory Blade Coater and Slot Die Coater
This article compares the coating precision of blade coaters and slot-die coaters in the laboratory. Blade coaters are suitable for thick coatings, with simple operation but relatively large uniformity errors; slot-die coaters offer higher precision and better uniformity for thin coatings. The choice of equipment depends on coating thickness and precision requirements.
Process optimization of heating coater in lithium battery electrode preparation
This article introduces process optimization methods for heating coaters in the preparation of lithium battery electrodes.
The Stripe Issue Caused by Tension Fluctuations in Roll-to-Roll Laboratory Coaters and Its Solutions
This paper analyzes the causes of and countermeasures for coating streaks resulting from tension fluctuations in roll-to-roll laboratory coaters.
Analysis of Common Defects in Laboratory Coating Machine Blade Coating and Adjustment Methods for Process Parameters
This article introduces common defects in the blade coating process of laboratory coaters, such as streaks, orange peel, bubbles, uneven thickness, and missed coating. It analyzes the causes of these issues, which are primarily related to material properties, operating parameters, and environmental factors.
Laboratory rod coater for submicron wet film preparation of photoresist.
This article introduces the process of using a laboratory bar coater to prepare submicron wet films of photoresist.
Application of Perovskite Coater in the Preparation of Intermediate Layers in Tandem Solar Cells
This article introduces the application of perovskite coating machines in the preparation of the intermediate layer of tandem solar cells.
Using a spray coater to achieve the preparation of functionally graded films.
This paper introduces a method for preparing functionally gradient films using a spray coating machine.
Application of Spray Coating Machines in the Encapsulation of Flexible Electronic Devices
This paper introduces the application of spray coating machines in the encapsulation of flexible electronic devices.
Roll-to-Roll Preparation of Perovskite Coaters for Flexible Perovskite Solar Cells
This article introduces the roll-to-roll fabrication method of flexible perovskite solar cells.
Operation Tips for Laboratory-Scale Hot Melt Adhesive Coating Machines
This article introduces the key operational points of a laboratory-scale hot melt adhesive coater. The equipment is primarily used in laboratories to apply hot melt adhesives uniformly onto substrates, supporting the research, development, and testing of adhesives.
Application of Continuous Coating Machine for Lithium Battery Electrode Preparation in Electrode R&D
The laboratory continuous coater is a key piece of equipment in lithium battery electrode research and development, used to simulate mass production coating processes. By precisely controlling parameters such as coating speed, thickness, and tension, it helps researchers optimize slurry formulations and coating procedures.
How to Coat High-Viscosity Slurry – Parameter Setting Tips for Blade Coaters
This article primarily discusses the parameter setting techniques for high-viscosity slurries on blade coaters. High-viscosity slurries exhibit characteristics such as shear thinning, so it is essential to leverage shear effects during coating to facilitate slurry spreading. After coating, the viscosity should recover quickly to prevent sagging.
Common Troubleshooting for Wire Bar Coater: Solving Issues of Streaking and Uneven Thickness
This article mainly introduces solutions to two common faults in the operation of the wire rod coater—coating streaks and uneven coating thickness.
Roll-to-roll coater enables continuous preparation of flexible electronic materials.
Roll-to-roll coating is a continuous production process that involves uniformly applying functional slurry onto a flexible substrate, followed by drying and curing to form a functional film.