High-temperature sensing sticker

High-temperature sensing stickers indicate the surface temperature of objects through irreversible color changes of thermosensitive materials at specific temperatures. They are used to monitor whether the temperatures in processes such as industrial heat treatment, welding, and electronic components meet the required standards, preventing overheating or insufficient heating.
Selection
When selecting, ensure that the required temperature measurement range matches the sticker's range; observe whether the color change is distinct and easily recognizable; consider the adhesion between the sticker's base material and the surface being measured; check whether the thermal response speed meets process monitoring requirements; confirm that the working environment is free from chemical corrosion or mechanical wear effects.

Terms

Instruments

Irreversible discoloration design, the temperature window from white to red is clearly recognizable, with oil-proof and waterproof protective film, the back sticker is easy to paste, can be stored for 2-3 years, each 120 pieces size 12x30mm.

$ 150.00

Dedicated to calibrating ammonia Gas sensing electRodes, capacity 250ml, providing accurate calibrating support to ensure Reliability of detection data.

$ 110.00

Adopting irreversible discoloration technology, when the temperature exceeds 70 ° C, it turns from white to black and displays numbers. The size is 60 * 8mm rectangular design, which is convenient for inspection to find temperature abnormalities and prevent failures.

$ 85.00

Using irreversible discoloration technology, when the temperature reaches 70 ° C, it turns from white to black and displays numbers, with a size of 40 * 8mm. Each sheet of 40 is easy to install and identify, and the temperature of the connection part is effectively monitored.

$ 86.00

Using irreversible discoloration technology, when the temperature reaches 70 ° C or 80 ° C, it turns from white to black and displays numbers. The size is 40 * 8mm rectangular design, which is easy to install and identify the over-temperature state.

$ 91.00

Using ceramic variable capacitance sensing technology, repeatability error +/- 0.01g, with Ambient Temperature Compensation and overload protection functions, the structure is sturdy and durable.

$ 587.00

ElectRode filling solution, suitable for ammonia Gas sensing electRode maintenance, capacity 480 ml, can effectively adjust the ionic strength, improve ElectRode Response Speed and Measurement accuracy.

$ 135.00

Using LT Glass sensing film, built-in temperature sensor, support Bluetooth 4.0 connection, transmission distance of 10 Meters, using CR2032 battery life of about 500 hours, suitable for micro vessel sample measurement.

$ 780.00

Glass composite ElectRode and LT Glass sensing film, Measurement range 0-12pH, built-in temperature sensor automatic compensation, small design for micro sample detection, Bluetooth 4.0 technology implementation 10 Meters wireless transmission.

$ 607.00

Repeatability and accuracy are ensured with dual optical path sensing arrays and UV reinforced silicon photodiodes with 0.0001 resolution, 0-200% Transmittance Measurement range and support for APHA/PtCo, Gardner and Saybolt chroma scales.

$ 1687.00

ElectRode filling solution is suitable for ammonia Gas sensing electRode maintenance, copper ion type, capacity 480 ml, to ensure ElectRode performance stability and measurement accuracy.

$ 135.00

ElectRode filling solution is suitable for ammonia Gas sensing electRode maintenance, providing bromine ion type and 480mL capacity to ensure stable ElectRode performance.

$ 135.00

Irreversible discoloration records the temperature. When the temperature is exceeded, the window is obviously visible from white to red. It has an oil-proof and waterproof protective film and a adhesive backing for easy pasting. Each sheet is 120 pieces, and the shelf life is 2-3 years.

$ 150.00

With 5 temperature monitoring points, Temperature range 77 ° C to 99 ° C, irreversible discoloration record, oil and water resistance, BS EN ISO 9001 compliant, with a sticker on the back for easy installation.

$ 92.00

Temperature range of 50~ 120 ℃, irreversible discoloration, over-temperature grid window from white to red, clear contrast, suitable for indoor and outdoor equipment temperature display.

$ 140.00

Articles

Application of Coating Thickness Gauges in Electroplating Thickness Detection
Coating thickness gauges are used to measure the thickness of electroplated layers, primarily employing the electromagnetic induction method for measuring non-magnetic coatings on magnetic substrates, or the eddy current method for measuring insulating coatings on non-magnetic metal substrates.
Eddy current thickness gauge measures metal coatings on non-conductive substrates.
The eddy current thickness gauge utilizes the principle of electromagnetic induction, generating an alternating magnetic field through the probe coil to induce eddy currents in the metal coating, thereby measuring thickness based on changes in coil impedance.
Comparison of Dual-Principle Instruments: Magnetic Induction vs. Eddy Current for Coating Thickness Measurement
This article compares the principles of two coating thickness gauges. The choice of method depends on the substrate material: magnetic induction is used for magnetic metals, while eddy current is applied for non-magnetic metals.
Eddy current thickness gauge detects coatings on non-ferrous metals.
The eddy current thickness gauge operates on the principle of electromagnetic induction, generating an alternating magnetic field through the probe coil, which induces eddy currents on the surface of non-ferrous metal substrates.
Magnetic thickness gauge measures the thickness of coatings on steel surfaces.
Magnetic thickness gauges are used to measure the thickness of non-magnetic coatings on ferromagnetic substrates such as steel, based on the principles of magnetic induction or changes in magnetic attraction. Prior to use, calibration should be performed according to relevant standards, and attention should be paid to factors such as substrate characteristics, workpiece shape, and surface conditions that may affect the measurements.
The principle of measuring dry film thickness with a coating thickness gauge
Coating thickness gauges measure dry film thickness through non-destructive methods, with commonly used principles including electromagnetic induction, eddy current, and ultrasonic methods.
What is a Coating Thickness Gauge? A Complete Analysis of Its Principles, Usage, and Application Areas
The article systematically elaborates on the working principles of two core measurement techniques, magnetic induction and eddy current, detailing the standard measurement process from calibration to data recording, and conducting an in-depth analysis of the influence of substrate characteristics, geometric shapes, and environmental factors on measurement accuracy.