Low Temperature Circulating Thermostat

The low-temperature circulating thermostatic bath reduces the liquid temperature through a refrigeration system, and works in conjunction with a circulation pump to maintain uniform and stable temperature within the bath. It is used for cooling laboratory samples, conducting low-temperature testing of materials, and simulating low-temperature environments in the coatings and inks industry to evaluate product performance.
Selection
When selecting, consider that the temperature range covers experimental needs, temperature control accuracy meets testing standards, tank capacity matches sample size, cooling power ensures the cooling rate, materials are corrosion-resistant and easy to clean, and the operation interface is intuitive for daily use and maintenance.

Terms

Standards

Instruments

Equipped with powerful pressure suction pump to support peripheral groove thermostatic, Temperature Fluctuation is only +/- 0.1 ℃, pump flow 4L/min, with over-temperature and low temperature sound and light alarm and liquid level protection functions to ensure sample safety.

$ 1389.00

Equipped with a strong pressure suction pump to provide a thermostatic source for the peripheral Tank, temperature accuracy +/- 0.1 ℃, over-temperature and low temperature sound and light tracking alarm and liquid level protection functions ensure the safety and reliability of the sample.

$ 877.00

Imported Pt100 temperature sensor and dual Compressor refrigeration system, rapid cooling and low noise, Temperature Fluctuation +/- 0.05 ℃, 6L volume Tank with 8L/min circulating pump to ensure Temperature uniformity.

$ 971.00

The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, with a Temperature Uniformity of +/- 0.0050 ° C, and multiple safety functions such as low water level protection and temperature runaway alarm.

$ 1927.00

Equipped with powerful pressure suction pump and imported Compressor, temperature control accuracy of +/- 0.1 ℃, support external Bath connection, with over-temperature alarm and liquid level protection function, pump flow 4L/min to ensure stable circulation.

$ 969.00

The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field. Temperature Uniformity reaches +/- 0.0050 ℃, with low water level protection and temperature runaway alarm function to ensure the safety and stability of the experiment.

$ 14703.00

Adopt non-heat centrifugal circulating pump to avoid its own heat generation affecting the temperature field, Temperature Uniformity +/- 0.0050 ℃, with low water level protection and temperature runaway alarm and other safety functions, accurate and stable temperature control.

$ 1703.00

Imported PT100 temperature sensor and double Compressor cascade refrigeration system, high refrigeration efficiency and low noise, Temperature Fluctuation +/- 0.05 ℃, Tank volume 30L, Circulating pump Flow rate 10L/min to ensure Temperature uniformity.

$ 3656.00

The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field. Temperature Uniformity reaches +/- 0.0050 ℃, with low water level protection and anti-dry burning functions, to ensure the safe and stable operation of the experiment.

$ 1335.00

The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, and the U-shaped return design realizes Temperature Uniformity +/- 0.0050 ℃, with low water level protection and Compressor multiple safety protection functions.

$ 7243.00

The use of non-heat centrifugal circulating pump to avoid affecting the temperature field, Temperature Uniformity of +/- 0.05 ℃, with low water level protection and Compressor multiple protection functions to ensure safe and stable operation.

$ 995.00

Adopt non-heat centrifugal circulating pump to avoid its own heat generation affecting the temperature field, Temperature Uniformity up to +/- 0.05 ℃, with low water level protection and Compressor multiple safety functions, optional program temperature control and Communication interface.

$ 1317.00

Temperature range -30~ 100 ℃, Temperature Fluctuation +/- 0.1 ℃, equipped with strong pressure suction pump and external connection port, support over-temperature low temperature sound and light alarm and liquid level protection functions to ensure the safety and reliability of the sample.

$ 2362.00

Adopt non-heat centrifugal circulating pump to avoid temperature field interference, Temperature Uniformity up to +/- 0.05 ℃, with low water level protection and Compressor multiple safety protection, optional program temperature control and magnetic stirring function.

$ 1794.00

Temperature range -50~ 100 ℃, Temperature Fluctuation +/- 0.2 ℃, equipped with over-temperature low temperature sound and light alarm and liquid level protection, support multi-stage programmable control, circulating pump Flow rate 8L/min, to ensure the safe and stable operation of the sample.

$ 3028.00

Articles

Application of High-Frequency Fatigue Testing Machine in Infinite Life Testing of Valve Springs
This article discusses the application of high-frequency fatigue testing machines in the infinite life testing of valve springs. The test simulates the long-term working stress of the spring through high-frequency cyclic loading, with parameters such as preload, amplitude, and cycle count set according to international standards.
Constant temperature bath selection: circulation method and temperature control range.
This article on thermostatic bath selection primarily analyzes two core factors: circulation mode and temperature control range. The circulation mode is divided into natural convection and forced circulation, where the former is suitable for simple static experiments, while the latter offers higher precision and is better suited for multiple samples or integration with external devices.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
The Impact of Cooling Circulating Water Chillers on the Temperature Stability of Digesters
The cooling circulator helps maintain a stable temperature for the digester by circulating the cooling medium, thereby improving the repeatability of experiments. Its working principle involves using a refrigeration system to lower the water temperature, and then circulating the cooled water to the digester through a circulation pump to absorb excess heat.
Effect of Rapid Temperature Change Aging Chamber on Thermal Cycling of Composite Materials
This article primarily explores how rapid thermal cycling chambers affect the performance of composite materials during thermal cycling. It explains that thermal cycling can induce internal stresses in composite materials due to differences in the thermal expansion coefficients of their components, potentially leading to microcracks or performance degradation.
Salt spray aging test chamber for cyclic corrosion evaluation of coating weatherability.
This article introduces the method of using a salt spray aging test chamber to conduct cyclic corrosion tests for evaluating the weather resistance of coatings.
High and low temperature alternating test chamber for measuring low-temperature embrittlement temperature of plastics
This article introduces how to use a high-low temperature alternating test chamber to determine the low-temperature brittleness temperature of plastics.
Thermal shock test chamber measures the thermal shock resistance of polymer films.
This article introduces how to test the thermal shock resistance of polymer films using a thermal shock test chamber. The test involves rapidly switching the film between high and low temperatures to simulate the drastic temperature changes that may occur in actual use, thereby generating thermal stress within the material.
Tensile testing machine measures the bending fatigue life of flexible OLED films.
This article introduces a method for testing the bending fatigue life of flexible OLED films using a tensile testing machine. The test simulates repeated bending to evaluate the accumulation of damage in the film under cyclic stress, and monitors performance changes to determine the failure point.
Thermal Shock Test Chamber Measures Film's Temperature Change Resistance
The thermal shock test chamber creates thermal stress inside the film by rapidly switching between high and low temperature environments, testing its resistance to temperature changes. During the test, key parameters such as temperature range and dwell time need to be set, and the film is observed for issues such as cracking or performance degradation.
Fatigue testing machine evaluates the long-term durability of resin-based composite materials.
The fatigue testing machine is a key piece of equipment for evaluating the long-term durability of resin-based composite materials. These materials are widely used in fields such as aerospace, but their performance gradually degrades under cyclic loading.
The Taber Abraser evaluates the wear resistance of coatings.
The Taber abrasion tester simulates surface wear of materials through rotational friction, used to evaluate the wear resistance of coatings. During testing, a grinding wheel is used to rub the specimen under a fixed load, and performance is quantified by measuring mass loss or thickness changes after a specified number of cycles.
Flash point tester for determination of closed cup flash point of varnish
This article introduces the method for determining the closed-cup flash point of varnish using a flash point tester. The flash point refers to the minimum temperature at which the vapor on the surface of the varnish ignites momentarily when exposed to a flame after heating. It is a crucial indicator for assessing the fire risk during its production, storage, and transportation.
Thermal Shock Test Chamber Evaluates Coating Thermal Stability
The thermal shock test chamber simulates sudden temperature changes by rapidly switching between high and low temperature environments, used to evaluate the thermal stability of coatings. In practical applications, coatings may develop internal stresses due to drastic temperature fluctuations, leading to issues such as cracking and peeling.