Ink Electric Thermostatic Drying Oven

The ink electric thermostatic drying oven heats the air through resistance wires and maintains a constant temperature inside the chamber with a temperature control system, accelerating the drying and curing of ink samples at the set temperature. It is used to test the drying speed, adhesion, and other properties of ink at different temperatures, making it suitable for quality inspection in printing factories and ink production enterprises.
Selection
When selecting, consider matching the chamber size to the sample volume, ensuring the temperature range covers common drying temperatures and the temperature control accuracy meets testing requirements. Pay attention to the balance between heating power and heating speed, and choose a chamber material that is corrosion-resistant and easy to clean. Review temperature uniformity data to ensure that temperature differences across all areas inside the chamber comply with standards.

Terms

Standards

Instruments

Temperature range RT + 10~ 300 ℃, Temperature Fluctuation +/- 1 ℃, equipped with stainless steel liner and observation window, uniform and stable heating, suitable for long-term thermostatic drying needs.

$ 557.00

Temperature range RT + 10~ 300 ℃, Temperature Fluctuation +/- 1 ℃, stainless steel liner corrosion resistance, electric heating tube heating fast and uniform, intelligent digital display easy to operate.

$ 403.00

Adopt hot air circulation system to ensure Temperature Uniformity +/- 2 ℃, support 1-9999 minutes timing control, with RS-485 communication interface optional, suitable for drying and sterilizing operations.

$ 333.00

The cavity preheating technology implementation uniform temperature distribution, equipped with forced convection system to shorten the temperature recovery time, temperature control accuracy +/- 1 ℃, support 0-9999 minutes timing and remote monitoring function.

$ 791.00

Temperature control accuracy of +/- 1 ℃, equipped with intelligent digital display and observation window, Inner Chamber dimensions 350 * 450 * 450mm, electric heating tube heating to ensure uniform and stable temperature.

$ 393.00

Temperature range RT + 10~ 300 ℃, Temperature Fluctuation +/- 1 ℃, equipped with stainless steel liner and observation window, uniform and stable heating, suitable for long-term thermostatic drying.

$ 441.00

Temperature range RT + 10~ 300 ℃, Temperature Fluctuation +/- 1 ℃, equipped with stainless steel liner and intelligent digital display to ensure uniform heating and long-term durability.

$ 557.00

The cavity preheating technology implementation uniform temperature distribution, equipped with forced convection system to shorten the temperature recovery time, support 0.1 ℃ temperature resolution and 0-9999 minutes timing function, to ensure the experimental environment stable and reliable.

$ 1192.00

Temperature range RT + 10~ 300 ℃, Temperature Fluctuation +/- 1 ℃, equipped with intelligent digital display and observation window, uniform and stable heating, suitable for a variety of material drying needs.

$ 356.00

Equipped with PID microcomputer intelligent temperature control system, Temperature Fluctuation +/- 1 ℃, temperature resolution 0.1 ℃; The studio is made of mirror stainless steel, Shelf spacing is adjustable, and the bottom heating hood quick-release structure is easy to clean.

$ 780.00

Temperature control accuracy of +/- 1.0 ℃, temperature resolution of 0.1 ℃, equipped with double-decked tempered Glass observation window and quick-release bottom heating hood, easy to clean and maintain, two heating power to meet different temperature needs.

$ 590.00

Adopt PID microcomputer intelligent temperature control, Temperature Fluctuation +/- 1.0 ℃, Temperature range RT + 10~ 300 ℃, equipped with double-decked tempered Glass observation window and quick-release bottom heating hood for easy cleaning and maintenance.

$ 716.00

Adopt PID microcomputer intelligent temperature control, Temperature Fluctuation +/- 1.0 ℃, equipped with 5-inch Touchscreen to support 10-stage program temperature control, studio mirror stainless steel material for easy cleaning and maintenance.

$ 829.00

Equipped with 5-inch Touchscreen to support 10-stage program temperature control, temperature control accuracy of +/- 1.0 ℃, can record 800 minutes of data and make an appointment for regular switch, the studio uses mirror stainless steel for easy cleaning and maintenance.

$ 1038.00

Temperature control accuracy of +/- 1.0 ℃, temperature resolution of 0.1 ℃, with two heating power adjustment, double-decked tempered Glass observation window for real-time monitoring, shelf load of 15kg.

$ 716.00

Articles

The Printability Tester Simulates the Effects of Different Printing Pressures on Offset Ink Transfer Rate.
This paper investigates how the printability tester simulates the effect of different pressures on ink transfer rate in offset printing.
Application of Gravure Printing Proofer in Water-based Ink Proofing and Pinhole Defect Evaluation
This article introduces how the gravure printability tester is used for water-based ink proofing and pinhole defect evaluation. Water-based inks are environmentally friendly but prone to tiny pinhole defects. The instrument enables standardized sample preparation and reduces human interference by controlling parameters such as cell depth and doctor blade angle.
The Application of Contact Angle Measurement Instruments in the Study of the Relationship Between Ink Printing Wettability and Substrate Surface Tension
This article introduces how a contact angle measuring instrument is used to study the relationship between wettability and substrate surface tension in ink printing. It first explains the principle, assessing the degree of wettability through the size of the contact angle, where an angle less than 90 degrees indicates good wettability.
Use of Fluorescence Spectrophotometer in Measuring Excitation and Emission Spectra of Anti-Counterfeiting Fluorescent Inks
This article introduces the application of fluorescence spectrophotometry in the spectral measurement of anti-counterfeiting fluorescent inks, including instrument calibration, sample preparation, and methods for measuring excitation and emission spectra.
Application of Flexographic Proofing Press in Evaluating Color Reproducibility of Flexographic Inks
This article primarily discusses the use of a flexographic proofer to evaluate the color reproducibility of flexographic inks. It introduces the role of the proofer in simulating production conditions and explains how to prepare samples by setting parameters such as pressure, speed, and anilox roll specifications.
The use of gravure proofing machines in the comprehensive evaluation of gravure ink printability and drying performance.
This article explores how a gravure proofing press can be used to comprehensively evaluate the printability and drying properties of gravure inks. The experiment tested the dot sharpness, transfer rate, and leveling properties of different inks using standard equipment, while recording drying times through the filter paper method and infrared temperature measurement.
The friction color fastness tester measures the amount of color transfer under dry and wet abrasion conditions for ink.
This article introduces a method for testing the amount of ink color transfer using a friction colorfastness tester, simulating both dry and wet rubbing conditions. Dry rubbing involves rubbing the ink surface with a dry white cotton cloth, while wet rubbing uses a white cotton cloth moistened with water.
Application of Linear Abrasion Tester in Testing Scratch Resistance of Printing Ink Coatings on Packaging
This article introduces the principle, method, and application of the linear abrasion tester in testing the scratch resistance of packaging printing ink coatings.
Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Determination of Thermal Decomposition Temperature and Inorganic Filler Content in Ink by Thermogravimetric Analyzer
This article introduces how to determine the thermal decomposition temperature and inorganic filler content of ink using a thermogravimetric analyzer. During the test, a small amount of ink sample is heated in a nitrogen or air atmosphere, and the mass change curve is recorded.
Application of Cone-and-Plate Viscometer in Determining the Rheological Curve of Non-Newtonian Fluids in UV Inks
This article introduces how a cone-plate viscometer measures the rheological curve of UV ink. UV ink is a non-Newtonian fluid whose viscosity changes with shear rate.
Spectrophotometer measures ink spectral reflectance and opacity.
This article introduces how to measure the hiding power of ink using a spectrophotometer. The instrument irradiates the ink sample, measures its reflectance within the visible light spectrum, and calculates the hiding power using the Kubelka-Munk model.
Surface Absorbency Tester for Predicting Drying Speed of Printing Ink on Coated Paper
This article explores how the surface absorbency tester predicts the drying speed of ink on coated paper. Traditional methods rely on actual printing tests, which are time-consuming and difficult to quantify.
Flexographic proofing press is used for evaluating the printability of water-based inks on kraft paper.
This article explores the use of flexographic proofing printability testers to evaluate the printing performance of water-based inks on kraft paper. The instrument simulates actual printing conditions, enabling quantitative analysis of key parameters such as ink transfer rate, print contrast, and dot gain.
Standard Procedure for Printability Tester in Evaluating Ink Transfer Performance
This article introduces the standard procedure for evaluating ink transfer performance using a printability tester. The transfer performance of ink directly affects print quality, and standardized operations can enhance the reliability of test results.