Bottle Base Thickness Measurement Instrument

The bottle bottom thickness gauge employs non-contact laser or ultrasonic technology, which calculates the time difference by emitting signals and receiving reflected waves, then converts it into thickness values. It is used to detect the thickness uniformity of glass and plastic bottle bottoms, ensuring packaging safety and quality control on production lines.
Selection
When selecting, consider the compatibility of the bottle material's light transmittance with the detection principle. The measurement range should cover common specifications from 0.1 to 20 mm. Environmental interference resistance should be suitable for workshop conditions. The calibration cycle and error values must comply with industry standards, and the operation interface should be intuitive and easy to read.

Terms

Standards

Instruments

With bottle bottom and bottle wall double measurement function, test resolution of 0.001mm, no power supply, easy and fast operation, suitable for small volume bottles such as ampoules and vials, general structure design is simple and durable.

$ 622.00

With bottle bottom and bottle wall double measurement function, test resolution of 0.001mm, no power supply, easy and fast operation, suitable for large bottles such as wine bottles and infusion bottles.

$ 661.00

Capacity 400ml/bottle, providing stable calibrating performance, suitable for a variety of instrument calibration needs, ensuring measurement accuracy and long-term Reliability.

$ 267.00

Using quartz time base technology to ensure accurate measurement, Maximum Measured value 750N, Real-time display of tension data and support for voice prompts, automatic storage of upper and lower limit setting values, providing USB, RS-232 and Bluetooth Data output methods.

$ 390.00

Capacity 400ml/bottle, using a stable formula to ensure long-term storage performance, suitable for calibrating and verifying various analytical instruments.

$ 228.00

Capacity 400ml/bottle, providing stable calibrating performance, ensuring measurement accuracy, suitable for a variety of experimental environments, easy and reliable operation.

$ 228.00

Adopt 00 grade granite structure to ensure stable accuracy, three-axis imported ball screw to ensure repeability positioning accuracy, equipped with programmable LED light source and industrial digital color camera, support autofocus and a variety of geometric measurement functions.

$ 10167.00

Capacity 400ml/bottle, using a stable formula to ensure long-term storage performance, suitable for calibrating a variety of instruments and improving experimental efficiency.

$ 267.00

Standard light sources including D65 and UV, seamless construction to ensure no light leakage, special steel plate base for enhanced durability, no preheating and low energy consumption, support for Illuminant use time display and automatic switching function.

$ 428.00

Maximum load of 0.5KN, designed for fixed Force Gauge displays, provides reliable clamping force, suitable for a variety of test scenarios, ensuring measurement Stability.

$ 369.00

With a capacity of 400ml/bottle, High Purity and Stability ensure the accuracy of experimental results, making it suitable for long-term storage and use.

$ 151.00

Using magnetic and eddy current two thickness measurement methods, Measurement range 0-1250μm, with automatic identification of iron and non-iron matrix function, support single point and two point calibrating, with power supply undervoltage indication and statistical function.

$ 170.00

Adopt magnetic Induction principle to measure 0-1250μm thickness, equipped with line Probe measurement groove and narrow area, support single point and two point calibrating, with automatic matrix recognition and undervoltage prompt function.

$ 186.00

Using 90 ° Measurement Angles and eddy Current principles, accurate measurement of edge coatings, narrow tube coatings and small surface areas ensures stable and reliable measurement on complex geometries.

$ 235.00

Clamping diaMeter 3-145mm, Measurement accuracy 0.001mm, using three/four jaw self-centering chuck and high degree of freedom bracket, 360 ° swirl/spin reading deviation value, to meet the needs of all kinds of bottle physical examination.

$ 929.00

Articles

Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
Mechanical thickness gauge for measuring film thickness uniformity.
The mechanical thickness gauge assesses the uniformity of film thickness through contact measurement. During measurement, the probe contacts the sample under standard pressure, converting displacement into a thickness reading.
Selection of Coating Thickness Gauges Using Magnetic and Eddy Current Methods on Different Substrates
This article introduces two main methods for coating thickness gauges: the magnetic method and the eddy current method. When choosing a method, the key is to determine it based on the electromagnetic properties of the substrate.
Application of Coating Thickness Gauges in Electroplating Thickness Detection
Coating thickness gauges are used to measure the thickness of electroplated layers, primarily employing the electromagnetic induction method for measuring non-magnetic coatings on magnetic substrates, or the eddy current method for measuring insulating coatings on non-magnetic metal substrates.
Coulometric thickness gauge measures the sealing quality of anodic oxide films.
This article introduces a method for assessing the sealing quality of anodic oxide films using a coulometric thickness tester. The sealing quality affects the corrosion resistance and wear resistance of the oxide film. Based on electrochemical principles, the coulometric thickness tester evaluates the sealing effectiveness by measuring the electric charge required to dissolve the oxide film, providing objective and repeatable results.
Ultrasonic thickness gauge for detecting thick coatings and composite coatings.
Ultrasonic thickness gauges measure coating thickness using the principle of ultrasonic pulse reflection, calculating the result based on the propagation time of sound waves in the material and the speed of sound. When detecting thick coatings and composite coatings, challenges such as acoustic attenuation of the material, unknown sound speed, and signal recognition at multi-layer interfaces must be addressed.
Eddy current thickness gauge measures metal coatings on non-conductive substrates.
The eddy current thickness gauge utilizes the principle of electromagnetic induction, generating an alternating magnetic field through the probe coil to induce eddy currents in the metal coating, thereby measuring thickness based on changes in coil impedance.
Coulometric Method Coating Thickness Gauge for Non-Destructive Measurement of Precious Metal Coatings
The coulometric coating thickness gauge measures the thickness by calculating the amount of electricity required to dissolve the precious metal coating through the principle of electrolytic dissolution. This method is non-destructive to the overall sample, only forming tiny electrolytic spots.
Comparison of Dual-Principle Instruments: Magnetic Induction vs. Eddy Current for Coating Thickness Measurement
This article compares the principles of two coating thickness gauges. The choice of method depends on the substrate material: magnetic induction is used for magnetic metals, while eddy current is applied for non-magnetic metals.
Application of Electrolytic Thickness Tester in Quality Control of Precision Electroplating Layers
The electrolytic thickness gauge measures coating thickness through the principle of electrochemical dissolution, calculating based on Faraday's law, offering high accuracy and independence from calibration.
Ultrasonic Thickness Gauge Measures the Thickness of Flexible Packaging Materials
This article introduces the principles, technical points, and operational procedures for measuring the thickness of flexible packaging materials using an ultrasonic thickness gauge. It is based on the principle of ultrasonic pulse reflection, which calculates thickness by measuring the propagation time of sound waves through the material.
Eddy current thickness gauge detects coatings on non-ferrous metals.
The eddy current thickness gauge operates on the principle of electromagnetic induction, generating an alternating magnetic field through the probe coil, which induces eddy currents on the surface of non-ferrous metal substrates.
Magnetic thickness gauge measures the thickness of coatings on steel surfaces.
Magnetic thickness gauges are used to measure the thickness of non-magnetic coatings on ferromagnetic substrates such as steel, based on the principles of magnetic induction or changes in magnetic attraction. Prior to use, calibration should be performed according to relevant standards, and attention should be paid to factors such as substrate characteristics, workpiece shape, and surface conditions that may affect the measurements.
The principle of measuring dry film thickness with a coating thickness gauge
Coating thickness gauges measure dry film thickness through non-destructive methods, with commonly used principles including electromagnetic induction, eddy current, and ultrasonic methods.
Standard Operating Procedure for Zero Calibration and Substrate Calibration of Coating Thickness Gauges
This article introduces two key calibration methods for coating thickness gauges: zero-point calibration and substrate calibration. During operation, it is important to ensure that the probe is perpendicular, pressure is applied evenly, and regular calibration and recording are maintained. These steps effectively enhance measurement accuracy and meet industry standard requirements.