Can be used with A type or C type Shore DuroMeter, fixed load weight mass 0.75 +/- 0.05kg, hardness Gauge clamping Rod connection size M7x0.5mm, improve hardness testing accuracy and Stability.
Supporting D-type Shore DuroMeter, applying 5kg test force by weight, equipped with Glass bench and adjusting nut to ensure full contact with the sample and improve measurement Stability.
Double pointer design for easy reading, Pin Travel 0~ 2.5mm, Measurement range 0~ 100HD, error +/- 1HD, lightweight and portable only 0.16kg, suitable for on-site Hardness detection.
With average value calculation and MAX Maximum latch function, support a variety of data output methods, Measurement range 10HA~ 90HA, resolution 0.1H, suitable for soft plastic, sponge and other hardness of materials detection.
Dual pointer design can display the current value and peak value at the same time, the pressure at the end of the crimp is 445mN, and the measurement error is +/- 1HD, which is suitable for plastic sample condition adjustment testing.
Travel 0-2.5 mm, measurement error +/- 1HA, can be used with a rack or hand-held operation to meet the requirements of standard test pieces and field object Hardness measurement.
Measurement range > 90B < 20D, support male/imperial unit conversion, with average calculation and MAX Maximum latch function, can output data in various ways through USB/RS-232/Bluetooth.
Double pointer design can be used with rack or hand, pressing needle Travel 0-2.5 mm, measurement error +/- 1HA, suitable for rubber and plastic hardness testing.
With average value calculation and data latch function, support a variety of data output interfaces, Measurement accuracy of +/- 1H, suitable for testing rubber and plastic materials in different Hardness ranges.
Using 0.79mm truncated cone stylus, Measurement range 20-90HA, resolution 0.1HA, support metric system conversion and average calculation, integrated design is easy to carry.
Pin Travel 0-2.5 mm, Measurement range 20-90HD, error +/- 1HD, weight only 0.16kg easy to carry, can be used with racks or handheld to meet different testing needs.
Measurement range 20~ 90A, error ≤ +/- 1H. With average value calculation, MAX Maximum latch function, support USB/RS-232 and Bluetooth Data output method.
Adopt R1.2 hemispherical pressure needle, Accuracy ≤ +/- 1H, support multi-unit measurement and automatic shutdown, suitable for soft rubber, thermal plasticity plastic and other materials, Operating temperature 0~ 50 ℃.
The all-in-one portable design weighs only 310g, supports metric and imperial unit switching, is equipped with average calculation and MAX Maximum latch function, Measurement accuracy ≤ 1HB, and can transfer data through USB/RS-232/Bluetooth interfaces.
Adopt double-pointer design, pressure needle Travel 0~ 2.5mm, measurement error +/- 1HAO, can be handheld or used with the bench, suitable for stable and fast detection of low Hardness rubber materials.