Providing stable copper Ion concentration standards to ensure ElectRode Measurement accuracy, 250ml Encasement meets the daily calibrating needs of the laboratory and is suitable for a variety of copper ion detection scenarios.
In line with ISO2808-1974 standard, the range is 0~ 150μm, the accuracy is not more than 5μm, can measure the wet film thickness and estimate dry-film thickness, suitable for laboratory and pRoduction control.
In line with ISO2808 standard, the range is 0~ 500μm, the accuracy is not more than 5μm, can measure the wet film thickness and estimate dry-film thickness, suitable for laboratory and pRoduction site.
Using eddy Current thickness measurement principle, Measurement range 0-1000μm, resolution 0.1μm, minimum measurable convex curvature 3mm, with automatic shutdown and low voltage prompt function.
Made of stainless steel, the thickness is only 1.5mm, the range is 20~ 200μm, Division 20μm, the card design is convenient for quick measurement of wet-film Coating thickness on site.
The three-wheel structure design is adopted, and the center wheel contacts the film directly for reading. The measuring range is 0-500 μm and the indexing is 25 μm. It can perform nondestructive thickness measurement on plane and curved surface.
Measurement range 0.00~ 5.00 ppm, accuracy +/- 0.05 ppm, using LED@575nm Illuminant, chemical reaction based rapid detection of copper Ion concentration, suitable for field and laboratory applications.
Roller type design, range 0~ 500μm, stainless steel material to ensure durability, suitable for on-site rapid measurement wet film thickness, in line with a number of execution standards.
Provide an additional one-year warranty period, which is applicable to Coating thickness Gauge pRoducts. It needs to be purchased simultaneously when purchasing the equipment and is not sold separately.
Dedicated to Coating thickness Gauge calibrating, ensure accurate thickness measurement, suitable for F type equipment, improve Reliability.
Stainless steel material is sturdy and durable, with a range of 50-950 microns, Division 50 and 100 microns, and a compact shape of only 65 * 43 * 1.5mm, suitable for rapid measurement of wet film thickness on site.
Measurement range 0~ 1250μm, suitable for LEEB220 and LEEB222 Coating thickness Gauge, Abrasion Resistance is good, suitable for a variety of nonmagnetic Coating thickness detection.
Using mechanical measurement method, Measurement range 0~ 1mm, accuracy ≤ 0.005mm, Graduation 0.001mm, probe diaMeter Φ 5mm, suitable for flat film and sheet, providing two probe pressure options.
The copper Cup ensures durability, the diaMeter of the flow hole is 4mm with the capacity of 100ml, and the measurement time range is 0~ 150s, which is suitable for conditional viscosity determination.
The three-wheel structure design is adopted, and the thickness of the center wheel contact film is directly read, with a range of 0-100 μm and a Graduation of 5 μm, which can be used for nondestructive measurement on planes and surfaces.