Purification Dry Box

The purification and drying cabinet filters and heats the air through a built-in high-efficiency filter and heating system, circulating it to remove particulate matter and control humidity. It is used in laboratory settings for sample storage, material processing, and other applications that require specific levels of environmental cleanliness and dryness.
Selection
When selecting a purification drying oven, considerations should include the size requirements of the usage space, the temperature control range, air cleanliness level, material corrosion resistance, energy consumption standards, and ease of equipment maintenance, ensuring compatibility with specific application conditions.

Terms

Standards

Instruments

Temperature uniformity is improved by fan speed control, the independent air duct circulation system automatically discharges water vapor, the dry culture mode is automatically converted, the temperature control accuracy fosters +/- 0.5 ℃, drying +/- 1 ℃, and the double door structure insulation does not affect the temperature in the box.

$ 722.00

Adopt fan speed control to improve Temperature uniformity, automatic discharge of water vapor, automatic conversion of dry culture mode, temperature control accuracy of +/- 0.5 ℃, Timer Range 1-9999 minutes.

$ 909.00

Adopt high temperature dry heat technology, destroy microbial cell protoplasm by oxidation. Temperature range RT + 10-300 ℃, Temperature Fluctuation +/- 1 ℃, with over-temperature alarm and timing function, mirror stainless steel liner is easy to clean.

$ 480.00

Adopt high temperature dry heat technology, Temperature range RT + 10~ 250 ℃, Input Power 1550W, with High Accuracy Microcomputer LCD display, automatic over-temperature protection and forced convection design, shorten disinfection time.

$ 716.00

Temperature control accuracy +/- 1 ℃, rapid heating and over-temperature automatic interrupt function, adjustable fan Rotation speed and timing control, easy to clean the box.

$ 838.00

Adopt high temperature dry heat technology, destroy microbial cell protoplasm by oxidation. Temperature range RT + 10-300 ℃, Temperature Fluctuation +/- 1 ℃, with over-temperature alarm, timing function and RS-485 communication interface, mirror stainless steel liner is easy to clean.

$ 622.00

Using high temperature dry heat technology, temperature control accuracy of +/- 1 ℃, rapid heating and over-temperature protection function, studio volume 70L, easy and safe operation.

$ 574.00

The centrifugal fan with low energy consumption and reasonable air duct design is used to achieve uniform and stable airflow; the average wind speed is 0.25 to 0.45m/s, and the noise is less than or equal to 62dB (A); it is equipped with initial effect and effective Filter to meet the requirements of purification level.

$ 1013.00

Adopt high temperature dry heat technology, effectively destroy the microbial cell structure through oxidation. Temperature range RT + 10~ 200 ℃, temperature fluctuation is only +/- 1 ℃, with forced convection system to improve heating efficiency, Multiple Safety protection mechanisms to ensure safe operation.

$ 438.00

With 70L studio volume, Temperature Fluctuation foster +/- 0.5 ℃; Adopt fan forced convection system to improve Temperature uniformity, automatically discharge water vapor and support intelligent conversion of dry culture mode to ensure convenient and reliable operation.

$ 585.00

Adopt high temperature dry heat technology, destroy microbial cell protoplasm by oxidation; Temperature range RT + 10~ 300 ℃, Temperature Fluctuation +/- 1 ℃; with over-temperature alarm, leakage protection and timing functions, mirror stainless steel liner is easy to clean.

$ 749.00

Temperature range from room temperature to 60 ℃, temperature control accuracy +/- 1 ℃. Equipped with air purification device and exhaust gas treatment system to prevent cross-contamination and meet environmental standards.

$ 5227.00

Temperature control accuracy +/- 1 ℃, rapid heating using forced convection mode, over-temperature automatic protection function to ensure safe operation, shelf can be moved to facilitate cleaning and maintenance in the box.

$ 961.00

Using high temperature dry heat technology to destroy microbial cell protoplasm through oxidation, Temperature range RT + 10-300 ℃, Temperature Fluctuation +/- 1 ℃, with over-temperature alarm, RS-485 interface and mirror stainless steel liner to ensure disinfection effect and equipment durability.

$ 1098.00

Using 3mm thick A3 steel plate and SUS201 stainless steel inner box, the size of each test box is 500 * 500 * 500mm, with pressure relief device and temperature and pressure control, effectively preventing battery explosion and ensuring safe operation.

$ 1535.00

Articles

Laboratory Drying Oven Model Selection - Difference Between Forced Air Convection and Non-Forced Air Convection
This article on the selection of laboratory drying ovens primarily introduces the differences between forced convection (air-blowing) and natural convection (non-air-blowing) drying ovens.
Selection of Clean Bench: Methods for Determining Airflow Direction and Cleanliness Class
This article primarily discusses the selection methods for clean benches, focusing on two aspects: first, determining the airflow direction based on experimental requirements—vertical laminar flow is suitable for protecting the operator, while horizontal laminar flow is ideal for protecting samples; second, selecting the cleanliness level according to ISO standards, typically requiring ISO Class 5.
Safety Considerations for Selecting Explosion-Proof vs. Ordinary Drying Ovens in Paint Laboratories
When selecting a drying oven in a paint laboratory, the type should be determined based on the safety risks of the samples and the environment.
Determination of dry matter content in pulp using an electric thermostatic drying oven.
This article introduces the method for determining the dry matter content of pulp using an electric thermostatic drying oven. Dry matter content is a key indicator for evaluating pulp quality. The principle of determination involves evaporating the moisture in the pulp through heating and calculating the content based on the mass difference before and after drying.
What are the differences between horizontal airflow and vertical airflow in a clean bench?
Purification workbenches primarily employ two types of air supply methods: horizontal and vertical. In horizontal air supply, the airflow is parallel to the work surface, while in vertical air supply, the airflow moves from top to bottom, forming a laminar barrier. The selection should be based on a comprehensive consideration of experimental needs, sample characteristics, and safety requirements.
How to Choose an Electric Hot Air Drying Oven? Read This Guide to Avoid Pitfalls
This article explains how to choose an electric air drying oven, with key performance parameters including temperature range, fluctuation, uniformity, heating rate, and working chamber size, which directly affect experimental outcomes.