Adopt magnetic thickness measurement method, measurement range 0-1250μm, error +/- 3%, with continuous and single measurement mode, can store 1560 measurement data, support a variety of calibrating methods.
Using magnetic Induction Measuring method, range 0~ 5mm, error +/- 5%, can measure a variety of non-ferrous magnetic coatings, suitable for different curvature substrate surface.
Measurement range 0~ 1250μm, suitable for LEEB220 and LEEB222 Coating thickness Gauge, Abrasion Resistance is good, suitable for a variety of nonmagnetic Coating thickness detection.
Using magnetic and eddy current two thickness measurement methods, Measurement range 0-1250μm, with automatic identification of iron and non-iron matrix function, support single point and two point calibrating, with power supply undervoltage indication and statistical function.
Measurement principle using magnetic method, thickness range 0-3000μm, error +/- 3%, with split Probe structure, support single and continuous Measurement mode, equipped with RS-232C interface.
Adopt magnetic Induction principle measurement, thickness range 0~ 1000μm, error +/- 3%, with low voltage prompt function, support split Probe and customized range, adapt to different curvature matrix measurement needs.
Adopting the principle of magnetic Induction Thickness Measurement range 0~ 1250 microns, suitable for LEEB242 models, can be connected to the printer output data, suitable for nonmagnetic Coating thickness detection on magnetic metal substrates.
Using magnetic Induction and eddy Current dual thickness measurement method, Measurement range 0-1500 μm, resolution 0.1 μm, support continuous and single measurement, with statistical function and 500 sets of data storage.
Using magnetic Induction and eddy current double thickness measurement method, Measurement range 0-1250μm, error +/- 3%, automatic identification of iron and non-iron matrix, with statistical function and undervoltage indication, easy to operate.
Using the magnetic induction method, the measurement range is 0~2000 μm, with an error of ±5%, a resolution of 0.1 μm. It supports separate probes and low-voltage alerts, and is suitable for various types of coatings.
Adopt magnetic Induction principle measurement 0-10mm thickness range, resolution up to 0.1μm, Probe wear-resistant more than 500,000 times, suitable for -10-50 ℃ environment, error range +/- 3%, stable and fast test.
Using magnetic Induction principle, Measurement range of 0-10000 μ m, support one and two point calibrating, split structure design can adapt to a variety of Probe types, to meet different Coating thickness measurement needs.
Using magnetic Induction and eddy Current Dual Measuring method, Measurement range 0~ 3000μm, accuracy +/- 2%, Probe wear resistance more than 500,000 times, Measurement speed of 0.3 seconds/time, suitable for various matrix materials.
Adopt magnetic Induction principle measurement Coating thickness, Measurement range 0-1250μm, resolution up to 0.1μm, with automatic identification Probe, Data storage and upper and lower limit alarm function, aluminum shell is sturdy and durable.
Measurement range 0-1250μm, support five probe types, zero point calibrating and continuous measurement function, equipped with USB interface to achieve data transmission.