With 0-100% measurement range and 0.1 resolution, accuracy +/- 2%, support ultraviolet-visible infrared three-band light transmitance measurement, swirl/spin Sensor for multi-angle testing, portable design for easy field use.
Using Semiconductor Sensor, Response Time T90 is less than 10 seconds, detecting a variety of combustible gases, range 0~ 50% LEL, with sound and light alarm and LED large screen display.
High-precision Sensor is used to detect PM2.5 concentration, Response Time is instantaneous, Sensitivity can be adjusted to 5PPM, with sound and light alarm and automatic warm-up function, continuous work for 5 hours.
Adopt non-light infrared NDIR Sensor, Response Time ≤ 15s, accuracy ≤ +/- 2%, support a variety of signal output and remote transmission, with overvoltage, lightning protection and other protection functions to ensure stable and reliable monitoring.
Simultaneous monitoring of four gases, Electrochemical sensor, Response Time less than 50 seconds, Operating temperature range -10~ 50 ℃, with sound and light alarm function.
With 350~ 9999ppm wide range detection range, Response Time of about 90 seconds, support sound and light dual alarm, built-in temperature measurement function, portable design weighs only 170 grams.
Light spectrum LED Illuminant and Light spectrum Sensor, equipped with 14mm and 5mm dual measurement aperture, haze Repeatability ≤ 0.03, with open measurement area to support liquid and large size sample detection.
Light spectrum LED light source, support sample surface free positioning measurement, repeability accuracy ≤ E * ab ≤ 0.07, Measurement speed of only 1.0 seconds, lightweight and portable.
Provide adjustable illuminance and Color temperature visible light, Color temperature range 2300K-8000K, illuminance up to 3000LX, infrared wavelength 850nm optional, radiation intensity greater than 400uW/CM ², stable light color without stroboscopic, life over 10,000 hours.
Using 380-1000nm Light spectrum instrument to achieve comprehensive measurement of total light transmitance, haze, color coordinates, etc. Precision wavelength +/- 0.3nm, built-in integrating sphere coating stable and durable, a variety of fixtures to meet the needs of liquid solid sample testing.
Electrochemical sensor to detect oxygen, range 0~ 25% VOL, Sensor life up to 5 years, Response Time ≤ 15 seconds, with sound and light alarm and continuous 90 hours of work ability.
Adopt non-light infrared NDIR Sensor, Response Time ≤ 15s, detection accuracy ≤ +/- 2%, support PPM,% VOL, mg/m ³ Unit switch, with overvoltage protection and automatic recovery function.
Adopting a non-light infrared NDIR Sensor, with a range of 0~ 1000ppm, Response Time ≤ 15 seconds, supports a variety of signal output and remote transmission, and has overvoltage protection and automatic recovery functions.
Using parallel illumination hemispherical scattering integrating sphere photoelectric receiving system, the light transmitance haze accuracy is up to 0.01%, with A/C/D65 three light sources and vertical-lying dual-use observation mode, support USB interface data export, LED light source long life fast start.
Measurement range 0.1-100 lx, accuracy +/- 3%, measurement of Flicker Frequency, Correlated Color temperature, Color rendering index, Blu-ray hazard ratio and other paraMeters, and display Spectral Curve.