Temperature range 10~ 200 ℃, Temperature Fluctuation +/- 1 ℃, using forced convection design to heat up quickly, over-temperature automatic interruption operation to ensure safety, shelf can be moved for easy cleaning.
Temperature range RT + 10~ 200 ℃ and resolution up to 0.1 ℃, forced convection design to shorten the rapid heating drying time, with over-temperature automatic protection and fan speed regulation function, shelf can be moved for easy cleaning and maintenance.
High Accuracy microcomputer temperature controller, temperature control accuracy of +/- 1 ℃, Temperature resolution of 0.1 ℃; forced convection design makes rapid heating, drying and disinfection time shortened; with over-temperature automatic interruption function to ensure safe operation.
Adopt the principle of high temperature dry heat disinfection, destroy the protoplasm of microbial cells by oxidation, Temperature range 10~ 200 ℃, Temperature Fluctuation +/- 1 ℃, with forced convection, three-speed fan speed regulation and timing functions to ensure efficient and safe disinfection.
Rated load 1000N, Travel 100mm, manual operation is stable, can adapt to a variety of Force Gauge, suitable for tension and compression load and plug force test, horizontal structure for desktop installation.
Temperature control accuracy +/- 1 ℃, rapid heating and over-temperature automatic interrupt function, adjustable fan Rotation speed and timing control, easy to clean the box.
Adopt high temperature dry heat technology, destroy microbial cell protoplasm by oxidation; Temperature range RT + 10~ 300 ℃, Temperature Fluctuation +/- 1 ℃; with over-temperature alarm, leakage protection and timing functions, mirror stainless steel liner is easy to clean.
Using high temperature dry heat technology to destroy microbial cell protoplasm through oxidation, Temperature range RT + 10-300 ℃, Temperature Fluctuation +/- 1 ℃, with over-temperature alarm, RS-485 interface and mirror stainless steel liner to ensure disinfection effect and equipment durability.
Adopt precision automatic control and data collection system to achieve full digitalization adjustment; with 1-400mm/min speed range and +/- 0.5% force value accuracy, support tensile compression bending and other test modes.
Full digitalization adjustment with precision automatic control, support 1-400mm/min speed range and 0.5% force value accuracy, with multiple test modes and real-time Linear dispersion display function.
With 200N range and 1-400mm/min speed range, automatic data collection system, support for tensile compression test and real-time display of force-deformation Linear dispersion, automatic calculation of 10 specimen statistics.
Adopt automatic control and data collection system to achieve full digitalization adjustment. Maximum range 300N, accuracy +/- 0.5%, provide a variety of test modes such as tensile, compression and bending test, support 10 samples to automatically calculate the average value.
Adopt automatic control and data collection system to realize full digitalization adjustment, force value Indication Error ≤ +/- 0.5%, effective Travel 170mm, support a variety of test modes such as tensile compression and bending test, improve Test accuracy.
Adopt precision automatic control and data collection system to achieve full digitalization adjustment. Measurement range 2000N, Test speed range 1-400mm/min, with 6 force value units and 3 displacement units, support a variety of test modes.
With 7-inch Touchscreen and four test modes, Force Indication Error ≤ +/- 0.5%, can customize 10 test points and automatically save 10000 data, integrated micro printer and multiple protection functions.