Using Optical inspection Measurement principle, the range covers 0.00-20 mg/L, without frequent replacement of membrane and electrolysis solution, easy maintenance, fast Response, suitable for long-term continuous monitoring.
Measurement range < 20DO, with MAX Maximum latch and automatic shutdown function, support USB and Bluetooth data output, resolution up to 0.1H, error ≤ 1H.
45 °/0 ° Optical inspection geometry, the measurement results are consistent with visual inspection; 8mm measurement diaMeter, Repeatability Delta E * ab within 0.08; built-in whiteboard paraMeters do not need each calibration, dual positioning technology to improve measurement accuracy.
Using diffuse transmission optical path design, optical density Measurement range 0.00-6 OD, light transmitance accuracy +/- 2%, can simultaneously measure light transmitance, absolute optical density, relative optical density and Dot area ratio.
Suitable for medium Hardness rubber and thermal plasticity resilience. Measurement range 0-100HDO, resolution 0.1HDO. Measurement mode of real-time, peak, timing and average. Linear dispersion analysis and storage.
Width 2cm, optical path 10mm, dimensions 12.5 × 22.5 × 45mm, specially designed for Spectrophotometer matching Cuvette, to ensure Optical inspection detection accuracy.
The width is 3cm, the optical path is 10mm, and the dimensions are 12.5 × 32.5 × 45mm. As a special accessory for Spectrophotometer, it ensures the stability of the optical path and the accuracy of measurement.
The width is 5cm, the optical path is 10mm, and the dimensions are 12.5 × 52.5 × 45mm, which is suitable for the use of Spectrophotometer to ensure Optical inspection detection accuracy.
Using photoelectric detection and microcomputer servo system, high Sensitivity, minimum reading +/- 0.005 °, Repeatability ≤ 0.007 °, low optical rotation samples with measurable transmittance ≥ 10%, no reading error.
The three-in-one optical path design can simultaneously measure the transmittance of blue light at 430nm, purple light at 395nm and visible light, and the test aperture Φ 1mm is suitable for large thickness materials. Real-time dynamic self-Adjustment ensures accurate data.
Optical inspection fluorescence method without reference solution, built-in temperature sensor to calibrate data in real time, dual range design covering 0~ 20mg/L and 0~ 200% Saturation, 10 Meters long cable to support deep water or remote installation, polyformaldehyde and stainless steel composite structure to enhance environmental adaptability.
Measurement principle of diffuse transmission, optical density Measurement range of 6.000 OD, accuracy +/- 0.02 OD, equipped with fixed seat and bracket, support two Measurement mode, suitable for translucent material testing.
Suitable for medium Hardness rubber, thermal plasticity resilience and other materials, Measurement range 0-100HDO, Indication Error ≤ +/- 1HDO, can be hand-held or matched with fixed load test bench, flexible operation.
Optical inspection system with infinity, 40X-1000X magnification range and N.A.1.25 Abbe condenser, support digitalization observation and a variety of auxiliary equipment expansion.
Infinity Optical inspection system, support a variety of Observation methods, equipped with six-hole objective lens converter and N.A.1.1 Abbe condenser, magnification 40X-1000X, easy and flexible operation.