Temperature range of -40~ 150 ℃ and 20~ 98% Humidity control, anti-condensation design of laminated Glass viewing window, support multi-stage program editing and fast slope control, meet a variety of standard test requirements.
Temperature range -40~ 150 ℃, Humidity range 20~ 98% RH, with multi-stage program editing and fast slope control function, double-decked air tight and sweat-proof viewing window design.
Adopt equilibrating Conditioning Control system, Temperature and Humidity control range -20~ 150 ℃ and 20~ 98% R.H., with multi-stage heating and energy saving functions to ensure long-term accurate operation.
Temperature range of -40~ 150 ℃ and 20~ 98% Humidity control, double-decked Glass view window anti-condensation design, built-in multi-stage program editing function, support for rapid or slope temperature and humidity control, Compressor system with environmentally friendly refrigerant.
Adopt equilibrating Conditioning Control system, Temperature range -60~ 150 ℃, Humidity range 20~ 98% R.H., with multi-stage intelligent output and energy saving functions to ensure long-term stable operation and reduce Power consumption.
Adopt equilibrating Conditioning Control system, Temperature range -20~ 150 ℃, humidity control 20~ 98% RH, equipped with imported Compressor and multi-stage PID calculation, ensure uniform and stable heat preservation Humidity, energy saving and high efficiency.
Adopt equilibrate Conditioning Control system to achieve High Accuracy Temperature Humidity Control, Temperature range -20~ 150 ℃, Humidity range 20~ 98% R.H., with multi-stage heating and energy saving functions to ensure long-term stable operation.
Temperature resolution up to 0.1 ℃, Humidity Control Range 60~ 85% RH, Mirror stainless steel liner easy to clean, independent temperature limit alarm system to ensure experimental safety.
Adopt equilibrate Conditioning Control system, Temperature and Humidity control range -40~ 150 ℃ and 20~ 98% R.H., equipped with imported Compressor and environmental protection refrigerant, with automatic calculation control and High Accuracy Stability, avoid test dead angle.
Using 7.0 inch Touchscreen controller, high temperature and humidity control accuracy, Fluctuation ≤ +/- 0.5 ℃, humidity deviation + 2, -3% R.H; built-in stainless steel humidifier, multi-wing air supply circulation, uniform temperature and humidity distribution, improve test reliability.
Adopt equilibrating Conditioning Control system, Temperature range -20~ 150 ℃, humidity control 20~ 98% RH, with multi-stage heating and energy-saving control valve, special air circulation design to ensure uniform temperature, built-in a variety of protection functions to ensure long-term stable operation.
Adopt equilibrate Conditioning Control system, equipped with imported Sanyo Compressor, Temperature range -60~ 150 ℃, Humidity uniformity +/- 1-3.0% R.H., with automatic calculation control and multiple protection functions.
Adopt equilibrating Conditioning Control system, Temperature range -60~ 150 ℃, Humidity Control Range 20~ 98% R.H., with multi-stage intelligent output and energy saving function, built-in automatic High Accuracy PID calculus control, ensure uniform and stable heat preservation Humidity.
Adopt stainless steel mirror liner and ultra-fine fiberglass insulation, Temperature Uniformity ≤ 2 ℃, humidity deviation + 2-3% R.H., with 100 sets of program storage and automatic calculation functions to improve test accuracy and efficiency.
Microcomputer temperature and humidity controller, Temperature Fluctuation +/- 0.5 ℃, humidity fluctuation +/- 5% RH, with over-temperature protection, independent temperature limit alarm system to ensure safe and stable operation of the experiment.