Dedicated to calibrating ammonia Gas sensing electRodes, capacity 250ml, providing accurate calibrating support to ensure Reliability of detection data.
ElectRode filling solution, suitable for ammonia Gas sensing electRode maintenance, capacity 480 ml, can effectively adjust the ionic strength, improve ElectRode Response Speed and Measurement accuracy.
ElectRode filling solution is suitable for ammonia Gas sensing electRode maintenance, copper ion type, capacity 480 ml, to ensure ElectRode performance stability and measurement accuracy.
ElectRode filling solution is suitable for ammonia Gas sensing electRode maintenance, providing bromine ion type and 480mL capacity to ensure stable ElectRode performance.
250Ml Encasement Specification for Ammonia Gas Sensitive and Ammonium Ion Composite ElectRode, provides routine concentration adjustment for measurement accuracy and Stability.
Measurement range pN value of 0.00~ 8.00, ammonia nitrogen concentration of 0.05~ 1000mg/L, with automatic mixing and thermostatic system, anti-sample Color, metal ions and turbidity interference, support a variety of reading methods.
The filling liquid capacity of 30mL, the use of PTFE bottles, Dimension 65mm high × 30mm diaMeter, weight of only 20g, suitable for the maintenance of Ammonia Gas sensing electRode.
Measurement range covers 0.05-1000 mg/L, glass sensitive film design, temperature range 5-45 ℃, equipped with Q9 connector to ensure stable detection of ammonia nitrogen content.
Designed for Ammonia Gas Sensitive Compound ElectRode, it provides a stable reference potential to ensure accurate measurement. The Encasement specification is 250ml, which is suitable for long-term monitoring applications.
Suitable for Ammonia Gas sensing electRode maintenance, capacity 480mL, Water Hardness Detection dedicated to ensure ElectRode performance stability, prolong service life.
ElectRode filling solution design, suitable for ammonia Gas sensing electRode maintenance, capacity 480mL, to ensure long-term stable operation of ElectRode, improve measurement accuracy.
ElectRode filling solution design, suitable for ammonia Gas sensing electRode maintenance, capacity 480mL, provide stable ion strength adjustment, ensure Measurement accuracy and ElectRode life.
ElectRode filling solution suitable for ammonia Gas sensing electRode maintenance, capacity 480mL, calcium ion type design to ensure measurement accuracy, prolong ElectRode life.
Detect NH3 gas, range 0~ 100ppm, resolution 0.1ppm, Response Time T90 ≤ 120s, support sound and light alarm, Operating temperature -10~ 50 ℃, Working time for more than 60 hours, Portable design weighs only 170 grams.
Measurement range 10-1~ 5 × 10-6mol/L, Temperature range 5-45 ℃, Glass sensitive film and Ag/AgCl reference structure ensure Stability and Accuracy, suitable for a variety of ion detection scenarios.