Fully Automatic Scraper Centrifuge

The fully automatic scraper centrifuge drives the drum to rotate at high speed via an electric motor, utilizing centrifugal force to separate solids from liquids in suspensions. The scraper automatically removes solid materials from the inner wall of the drum after shutdown. It is used for solid-liquid separation in industries such as chemical, pharmaceutical, and food processing, enabling material recovery and waste residue treatment.
Selection
When selecting, consider the viscosity and particle characteristics of the processed material, and match the corrosion resistance of the drum material. Determine the drum capacity based on the production scale, and choose between vertical or horizontal structures in combination with site dimensions. Pay attention to the automation level of the control system and the wear resistance of the scraper blades to ensure compliance with safety standards.

Terms

Standards

Instruments

The kit can realize automatic grinding fineness Gauge operation, improve test Repeatability, suitable for standard scraper fineness Meter supporting use, simplify the experimental process.

$ 1623.00

The 6-well design supports 15ml capacity Sample Handling, which is suitable for a variety of Centrifuge models and provides stable centrifugal separation results.

$ 127.00

Using positive pressure test principle, Measurement range 0~ 1.6MPa, fully automatic operation, support three test modes, built-in calibrating program, suitable for quantitative measurement of various sealing performance indicators.

$ 1332.00

Using removable scraper and vacuum adsorption system, Spreader accuracy +/- 0.003mm, Spreader rate 5~ 180mm/s, heating temperature up to 180 ℃, improve film Stability and uniformity.

$ 7496.00

Adopt removable scraper for easy cleaning and replacement, with bracket design to improve running Stability; Spreader accuracy of +/- 0.003mm, Film thickness range of 0~ 10mm adjustable, effective Spreader area of 400 * 300mm, through stepless speed control to ensure uniform Spreader.

$ 2333.00

It is designed with 24-hole 0.5ml specification, suitable for a variety of Centrifuge models, with high temperature resistance and high voltage characteristics and excellent chemical Stability.

$ 127.00

The fully automatic electronically controlled hydraulic pump provides smooth and continuous pulling force with +/- 1% accuracy, built-in rechargeable battery supports 200 tests, and IP65 Protection Rating ensures durability.

$ 4212.00

Support 100 ℃ high temperature heating, suitable for 24 holes 5ml centrifuge tube, optional electronic ice box and thermostatic metal Bath module, achieve precise temperature control and diverse Sample Handling.

$ 175.00

The 12-well design has a capacity of 5ml per well, uses high transparency material for easy observation of samples, has excellent chemical Stability, and is suitable for mainstream Centrifuge models to improve experimental efficiency.

$ 127.00

Double-sided horizontal mounting design can accommodate 40 5ml centrifuge tubes, suitable for standard centrifuge tube specifications, improving Sample Handling efficiency and ease of operation.

$ 149.00

44 1.5ml or 2.0ml centrifuge tubes can be installed vertically on both sides, providing efficient Sample Handling capability, adapting to a variety of centrifuge tube specifications, and improving the convenience of experimental operation and space utilization.

$ 149.00

Support 100 ℃ thermostatic treatment, compatible with 35 1.5ml centrifuge tubes, optional 4-degree electronic ice box and intelligent thermostatic module, suitable for a variety of experimental scenarios.

$ 148.00

12 10ml or 15ml centrifuge tubes can be installed vertically on both sides, providing stable fixation and efficient mixing. They are suitable for a variety of centrifuge tube specifications and enhance the convenience of experimental operation.

$ 149.00

Effective Spreader width 300mm, suitable for all kinds of scraper type Film Applicators, to ensure the uniformity of Spreader, improve the film accuracy and conformity in the experiment or pRoduction.

$ 235.00

Support high temperature treatment at 100 ° C, adapt to 20 0.5ml and 15 1.5ml centrifuge tubes, and use thermostatic metal Bath design to ensure uniform and stable temperature and improve experimental efficiency.

$ 148.00

Articles

Application of Gravure Printing Proofer in Water-based Ink Proofing and Pinhole Defect Evaluation
This article introduces how the gravure printability tester is used for water-based ink proofing and pinhole defect evaluation. Water-based inks are environmentally friendly but prone to tiny pinhole defects. The instrument enables standardized sample preparation and reduces human interference by controlling parameters such as cell depth and doctor blade angle.
Standard ink film preparation with a blade coater before tack testing of offset printing inks.
This article introduces the method of preparing a standard ink film using a blade coater before testing the tackiness of offset printing inks. It explains the principle of controlling ink film thickness by adjusting the blade gap and details the operational steps from securing the substrate and applying the ink to completing the coating process.
Study on the Dispersion Uniformity of Blade Coating Machines in High-Load Electrode Slurry Coating
This article investigates how to optimize the dispersion uniformity of coatings by adjusting process parameters when using a blade coater to handle high-load electrode slurries.
The wire bar coater with heating and vacuum adsorption is used for the preparation of perovskite solar cell layers.
This article introduces a new technique for preparing the light-absorbing layer of perovskite solar cells: a wire-bar coater with heating and vacuum adsorption capabilities.
Heating and blade coating of gel electrolyte films for zinc-ion batteries.
This article introduces the heating doctor-blade coating method for preparing gel electrolyte films in zinc-ion batteries. The method involves spreading a slurry onto a substrate using a doctor blade, followed by heating to evaporate the solvent and form a film.
Blade-coating preparation of hole transport layers for perovskite solar cells.
This article introduces the method of preparing the hole transport layer for perovskite solar cells using the doctor-blade coating technique. The doctor-blade coating method involves spreading the solution evenly on the substrate with a blade to form a thin film, making it suitable for large-scale production.
Preparation of composite films by coating mechanism for electrical performance experimental characterization
This article introduces the method of preparing composite films using a film coating machine and testing their electrical properties. The film coating machine evenly spreads the slurry with a blade, controlling thickness and uniformity. The preparation process includes raw material preparation, substrate treatment, coating, and curing.
Operating Specifications and Result Interpretation of Paint Fineness Gauges
The fineness gauge is used to measure the dispersion of particles in paint. During operation, the sample should be applied to the groove under standard conditions, and a scraper is used to spread it evenly to form a wet film. The particle visibility is then observed under appropriate lighting, and the fineness value is read from the corresponding scale.
Application of Two-Step Method with Pre-Coating and Fine-Coating in Eliminating Bubble Defects for Dual-Blade Coater
The dual-blade coater employs a two-step method of pre-coating and precision coating to eliminate bubble defects during the coating process. In the pre-coating stage, high shear force is applied to break the bubbles in the slurry, causing them to rupture and rise to the surface. The precision coating stage then precisely controls the coating thickness, removing any remaining bubbles to form a uniform wet film.
Experimental Verification of Stroke Accuracy on Coating Thickness Repeatability for Desktop Automatic Film Applicators.
This article investigates the influence of the stroke accuracy of a desktop automatic coating machine on the repeatability of coating thickness. The experiment monitored the blade position deviation using high-precision sensors and measured the coating thickness, revealing that smaller stroke deviations lead to better repeatability in coating thickness.
Copper nanowire and zinc oxide thin film preparation coater
The coating machine is a key device for preparing copper nanowires and zinc oxide thin films, which uniformly coats slurry onto a substrate through methods such as blade coating to form a thin film.
The laboratory coating machine easily coats various aqueous and oily slurries.
The laboratory film applicator is a precision instrument used to prepare uniform coatings on substrates, primarily operating on the principle of a blade or wire-wound rod. It allows adjustment of parameters such as speed and pressure to control coating thickness.
Graphene Transparent Conductive Film Coating Process and Coater Selection
This article introduces the coating processes and coating machine selection for graphene transparent conductive films. The coating processes primarily include blade coating, slot-die coating, spin coating, and spray coating, with choices depending on the properties of the dispersion, the type of substrate, and the production scale.
The role of the coating machine in the preparation of fuel cell membrane electrode assemblies
The film coating machine is a key equipment for preparing the membrane electrode, the core component of fuel cells. It evenly coats a catalyst-containing slurry onto a substrate using techniques such as blade coating, slot-die extrusion, or spraying, forming a catalytic layer ranging from a few micrometers to several tens of micrometers in thickness.
The laboratory coating machine is used for perovskite battery research and development.
The laboratory film coater is a key piece of equipment in the research and development of perovskite solar cells, used for the precise preparation of perovskite functional layer thin films. By controlling parameters such as coating speed and blade gap, it influences the thickness and uniformity of the wet film, thereby determining the crystallization quality of the film and the final performance of the solar cell.