Paper Preparer

The paper sheet former evenly spreads and forms pulp through mechanical means to create standardized test sheets. It is used in laboratories to simulate the paper production process and to examine pulp characteristics and paper properties. It is suitable for quality control and research and development testing in the papermaking industry.
Selection
When selecting, consider the molding dimensions matching the test standards, the corrosion resistance of the material to suit the characteristics of the slurry, the control precision meeting the experimental requirements, and balancing the ease of operation and maintenance costs according to actual usage conditions.

Terms

Standards

Instruments

Vacuum principle measurement paper breathability performance, Measurement range 0-1000ml/min, test area of 10cm ², suitable for a variety of industrial paper mass detection.

$ 1134.00

The sampling size of the equipment is 300 * 320mm, and the parallelism of the incision is less than or equal to 0.1mm. It can accurately detect the mechanical properties such as paper tension resistance, elongation and fracture length, and meets the requirements of many national standards.

$ 211.00

Measurement range 10~ 500mN, resolution 5mN, tear arm 104mm, paper size 25 * 15mm, suitable for accurate determination of paper Tear strength.

$ 782.00

Using the Cobb test method, the test area is 100cm ² +/- 0.2, and the pressure roller mass is 10kg +/- 0.5, which is suitable for the detection of Water Absorbency on the surface of sizing paper and Cardboard, and is not suitable for loose or unsizing paper.

$ 848.00

Measurement range 0-20mm, accuracy 0.001mm, contact pressure 20 +/- 5kPa, suitable for paper, Cardboard and sheet material Film thickness detection, in line with a number of international standards.

$ 401.00

Measurement range 0~ 1000ml/min, test area 10cm ², test area pressure difference 1kPa, suitable for a variety of industrial paper ventilation performance detection.

$ 935.00

The Water Absorbency of paper surface was measured by Cobb test method, the test area was 100cm ², the cylinder height was 50mm, the absorbent paper Basis Weight was 200~ 250g/m2, and the pressure roller mass was 10kg to ensure the accuracy of the test.

$ 648.00

Measurement range 10~ 1000mN, Indication Error +/- 1%, suitable for a variety of paper samples, to ensure test accuracy and Repeatability, easy and reliable operation.

$ 998.00

Suitable for paper tubes with an outer diaMeter of 200mm, automatic return and judgment of crushing force, adjustable speed of 10~ 150mm/min, High Accuracy Sensor ensures accurate sampling, supports a variety of Unit switching and direct printing.

$ 1174.00

Suitable for inner paper tube testing with an outer diaMeter of 400mm, with a capacity of 500kg and an adjustable speed of 10-80mm/min, it automatically judges the crushing force and supports data printing function.

$ 1727.00

Vacuum Level 100 or 200 mm water column constant test, Measurement range 0-1000ml/min, test area 10cm ², support a variety of paper ventilation performance evaluation.

$ 1151.00

Tensile Strength and elongation paraMeters can be detected, test force 500-3000N optional, accuracy +/- 1%, stepless speed 1-500mm/min, suitable for all kinds of paper and Cardboard materials.

$ 1516.00

It adopts wear-resistant inks and thickened steel knife design, is equipped with paper cutting guide ruler and paper pressing anti-skid function, and the sampling size is 380 * 300mm to ensure accurate sampling and stable operation.

$ 283.00

Test area of 100cm ², press roller mass 10kg, can accurately determine the surface of the paper liquid absorption mass, in line with international standards.

$ 533.00

Fixed cut 15mm wide sample, sampling width error +/- 0.1mm, parallelism on both sides ≤ 0.1mm, suitable for a variety of paper test items.

$ 315.00

Articles

Application of Gravure Printing Proofer in Water-based Ink Proofing and Pinhole Defect Evaluation
This article introduces how the gravure printability tester is used for water-based ink proofing and pinhole defect evaluation. Water-based inks are environmentally friendly but prone to tiny pinhole defects. The instrument enables standardized sample preparation and reduces human interference by controlling parameters such as cell depth and doctor blade angle.
Use of Fluorescence Spectrophotometer in Measuring Excitation and Emission Spectra of Anti-Counterfeiting Fluorescent Inks
This article introduces the application of fluorescence spectrophotometry in the spectral measurement of anti-counterfeiting fluorescent inks, including instrument calibration, sample preparation, and methods for measuring excitation and emission spectra.
Application of Flexographic Proofing Press in Evaluating Color Reproducibility of Flexographic Inks
This article primarily discusses the use of a flexographic proofer to evaluate the color reproducibility of flexographic inks. It introduces the role of the proofer in simulating production conditions and explains how to prepare samples by setting parameters such as pressure, speed, and anilox roll specifications.
Laboratory rod coater for submicron wet film preparation of photoresist.
This article introduces the process of using a laboratory bar coater to prepare submicron wet films of photoresist.
Application of Perovskite Coater in the Preparation of Intermediate Layers in Tandem Solar Cells
This article introduces the application of perovskite coating machines in the preparation of the intermediate layer of tandem solar cells.
Using a spray coater to achieve the preparation of functionally graded films.
This paper introduces a method for preparing functionally gradient films using a spray coating machine.
Roll-to-Roll Preparation of Perovskite Coaters for Flexible Perovskite Solar Cells
This article introduces the roll-to-roll fabrication method of flexible perovskite solar cells.
Extended Application of Paper Water Absorption Tester in the Dispersibility Evaluation of Tissue Paper
This article explores how to extend the application of an instrument originally used for testing the water absorption capacity of paper to evaluate the dispersibility of tissue paper.
Application of Automatic Coating Machines in the Preparation of Ceramic Coatings for Lithium-Ion Battery Separators
This article discusses the application of automatic film coating machines in the preparation of ceramic coatings for lithium battery separators. Traditional manual coating methods often result in uneven coatings, which can adversely affect battery performance.
Standard ink film preparation with a blade coater before tack testing of offset printing inks.
This article introduces the method of preparing a standard ink film using a blade coater before testing the tackiness of offset printing inks. It explains the principle of controlling ink film thickness by adjusting the blade gap and details the operational steps from securing the substrate and applying the ink to completing the coating process.
Application of Laboratory Coating Machines in the Coating of Optical-Grade PET Anti-Reflection Coatings
This article discusses the application of laboratory coating machines in the preparation of anti-reflective coatings on optical-grade PET substrates. By controlling parameters such as coating speed and gap, the coating machine enables precise adjustment of coating thickness, thereby enhancing light transmittance and reducing reflection.
The wire bar coater with heating and vacuum adsorption is used for the preparation of perovskite solar cell layers.
This article introduces a new technique for preparing the light-absorbing layer of perovskite solar cells: a wire-bar coater with heating and vacuum adsorption capabilities.
Application of Automatic Coating Machines in the Preparation of Ceramic Coatings for Lithium Battery Separators
This article introduces the application of automatic coating machines in the preparation of ceramic coatings for lithium battery separators. Traditional
Salt spray test chamber for testing the corrosion resistance of plastic coatings.
The salt spray test chamber accelerates the testing of the corrosion resistance of plastic surface coatings by simulating a salt spray environment containing chloride ions. The test is conducted in accordance with international standards such as ASTM B117 or ISO 9227, and the process includes sample preparation, salt spray exposure, and result evaluation.
Differential Scanning Calorimetry for Measuring the Melting Temperature of Thin Films
Differential scanning calorimetry analyzes thermal transitions in materials by measuring the heat flow difference between the sample and a reference. When determining the melting temperature of thin films, the sample must be uniformly prepared, with a mass between 3 and 10 milligrams. Testing is typically conducted at heating rates ranging from 5 to 20°C/min under a nitrogen protective atmosphere.