Environmental Cold and Heat Test Chamber

The environmental cold and hot test chamber simulates temperature changes through cooling and heating systems, cycling the sample within a set temperature range. It is used to test the performance stability of materials under temperature variations and is commonly employed in temperature resistance testing for products such as electronic components, coatings, and plastics.
Selection
When selecting, consider that the temperature range covers the testing requirements, the heating and cooling rates match the standards, the chamber size accommodates the samples, the control accuracy complies with specifications, the recording function meets data traceability needs, and energy consumption and maintenance costs fit the budget.

Terms

Standards

Instruments

Using fluorine-free environmental protection refrigerant and imported Compressor, temperature control accuracy +/- 0.5 ℃, equipped with independent temperature limit alarm system, support multi-stage programmable control, easy to automate the operation of complex test process.

$ 5110.00

Using non-fluorine environmental protection refrigerant and imported Compressor, Temperature Uniformity +/- 2 ℃, with 100 sets of programmable control, support color Touchscreen operation and remote monitoring function, built-in multiple Safety protection system.

$ 16459.00

Using non-fluorine environmental protection refrigerant and imported Compressor, Temperature Uniformity +/- 2 ℃, equipped with programmable Touchscreen controller, supports multi-stage program control and real-time data monitoring to ensure stable and reliable testing process.

$ 6983.00

Temperature range -60~ 150 ℃ and Humidity control 30~ 95% R.H., equipped with fluorine-free environmental protection refrigeration system; color Touchscreen supports multi-stage programming, with independent alarm and multiple Safety protection functions.

$ 17545.00

Using non-fluorine environmental protection refrigerant and imported Compressor, Temperature Uniformity +/- 2 ℃, with multi-stage programmable control and independent temperature limit alarm system, support data export function.

$ 14388.00

Using non-fluorine environmental protection refrigerant and imported Compressor, Temperature Uniformity +/- 2 ℃, with multi-stage programmable control function, support 100 sets of program settings, equipped with independent temperature limit alarm system to ensure safe operation.

$ 6194.00

Using fluorine-free environmental protection refrigerant and imported Compressor, Temperature range -20~ 150 ℃, humidity control 30~ 95% R.H., with independent temperature limit alarm and multiple Safety protection functions, support multi-stage programmable control.

$ 4138.00

Using fluorine-free environmental protection refrigerant and imported Compressor, temperature control accuracy +/- 0.5 ℃, Humidity deviation +/- 3% RH, with multi-stage programmable control and multiple Safety protection functions.

$ 6194.00

Using non-fluorine environmental protection refrigerant and imported Compressor, Temperature Uniformity +/- 2 ℃, equipped with independent temperature limit alarm system and multi-function programmable controller, support data export and remote monitoring function.

$ 8857.00

Using fluorine-free environmental protection refrigerant and imported Compressor, Temperature range -40~ 130 ℃, uniformity +/- 2 ℃, with 120 sets of programming and multiple Safety protection systems, support data communication and real-time monitoring.

$ 5208.00

Temperature range -40~ 130 ℃, Temperature Uniformity +/- 2 ℃, using fluorine-free environmental protection refrigerant and imported Compressor, with 120 groups of programmable control and independent temperature limit alarm system, support Interface for easy monitoring.

$ 6292.00

Temperature range -40~ 130 ℃ and uniformity +/- 2 ℃, using fluorine-free environmental protection refrigeration system, equipped with multi-stage programmable control and independent temperature limit alarm function to ensure the safety and stability of the experimental process.

$ 5405.00

Using Japan's Panasonic Compressor and the United States DuPont environmental protection refrigerant, temperature control accuracy of +/- 0.5 ℃, Temperature resolution 0.01 ℃, with program control and Data storage functions, support high temperature, low temperature and heat and humidity alternating test.

$ 5479.00

With microcomputer programming control, can independently set the temperature Illumrination degree, light intensity 0~ 12000LX adjustable, Temperature Fluctuation +/- 0.5 ℃, support power-off memory and internal dehumidification function to ensure a stable environment.

$ 1705.00

Unique air duct circulation system is used to ensure that the wind is uniform and does not hurt the seedlings, supports 30-stage temperature and Humidity light programmable control, temperature fluctuation +/- 0.5 ℃, can simulate day and night temperature changes and multi-directional Illuminant environment.

$ 1655.00

Articles

How is a high-temperature muffle furnace applied in ash determination?
This article introduces the application of high-temperature muffle furnaces in ash determination. The principle of ash determination involves completely burning the sample at high temperatures, leaving behind inorganic mineral residues. The muffle furnace provides a stable and controllable thermal environment, ensuring accurate results.
Transverse Burst Strength Tester for the Evaluation of Impact Resistance of Corrugated Cardboard
This article explains how a lateral bursting strength tester is used to evaluate the impact resistance of corrugated cardboard. It measures the energy absorbed by the cardboard at the point of rupture using the pendulum impact principle, requiring the preparation of specimens according to standards and the control of environmental conditions during testing.
Sensitivity Enhancement of Dark Box UV Analyzers in Thin-Layer Chromatography Fluorescence Detection
This article explores how to enhance the sensitivity of dark box ultraviolet analyzers in fluorescence detection for thin-layer chromatography. Sensitivity is influenced by factors such as light source stability, wavelength accuracy, sample background, and ambient light.
Application of Transparent Constant Temperature Water Bath in Visualization of Material Thermal Deformation
The constant temperature water bath provides a stable environment for observing the deformation of materials after heating by maintaining a constant and uniform temperature of the liquid medium.
Temperature-controlled Rotational Viscometer Simulates Coating Rheology in Construction Environments
This article introduces how to use a temperature-controlled rotational viscometer to simulate construction environments in order to study the flow characteristics of coatings. The viscosity of coatings changes under different temperatures and shear conditions, which affects their application performance.
High-temperature aging test chamber accelerates life testing of electronic components.
The high-temperature aging test chamber accelerates the physical and chemical changes within electronic components by simulating high-temperature environments, thereby predicting their long-term performance and failure modes.
Application of Xenon Lamp Aging Test Chamber in Automotive Coatings ASTM G155
Xenon lamp aging test chambers simulate environmental conditions such as solar radiation, temperature, and humidity to evaluate the weather resistance of automotive coatings under the ASTM G155 standard.
Safety Considerations for Selecting Explosion-Proof vs. Ordinary Drying Ovens in Paint Laboratories
When selecting a drying oven in a paint laboratory, the type should be determined based on the safety risks of the samples and the environment.
Light source configuration and color matching environment requirements in the selection of standard light boxes
This article discusses how to choose a standard light booth, focusing mainly on the light source configuration and observation environment.
Application of Coating Rate Cardboard in the Determination of Coating Rate for Architectural Coatings
Coating rate card paper is a standardized substrate used to determine the spreading rate of architectural coatings. It features a smooth surface and stable parameters, which help minimize the influence of substrate variations and environmental factors associated with traditional methods.
Negative pressure method leak detector for testing vacuum packaging seal integrity
The negative pressure leak detector evaluates the seal integrity of vacuum packaging by simulating a pressure differential environment. The instrument places the sample in a testing chamber and creates a vacuum to form negative pressure. If there is a leak, air or liquid will seep into the packaging, and the result is determined by observing pressure changes or the presence of bubbles.
Thermal Shock Test Chamber Measures Film's Temperature Change Resistance
The thermal shock test chamber creates thermal stress inside the film by rapidly switching between high and low temperature environments, testing its resistance to temperature changes. During the test, key parameters such as temperature range and dwell time need to be set, and the film is observed for issues such as cracking or performance degradation.
Salt spray test chamber for testing the corrosion resistance of plastic coatings.
The salt spray test chamber accelerates the testing of the corrosion resistance of plastic surface coatings by simulating a salt spray environment containing chloride ions. The test is conducted in accordance with international standards such as ASTM B117 or ISO 9227, and the process includes sample preparation, salt spray exposure, and result evaluation.
Ozone Aging Test Chamber Evaluates Crack Resistance of Rubber
This article introduces how an ozone aging test chamber is used to evaluate the crack resistance of rubber. Ozone is a common factor that causes rubber aging. The test chamber simulates an ozone-containing environment, applies strain to rubber samples, and accelerates their aging process.
Constant Temperature and Humidity Chamber for Testing Packaging Moisture and Heat Resistance
This article introduces the method of using a constant temperature and humidity test chamber to test the resistance of packaging to heat and humidity. The test chamber simulates hot and humid environments by controlling temperature and humidity, thereby evaluating the performance changes of packaging materials.