Impedance input controller, equipped with two-stage signal amplifier, Measurement accuracy of +/- 0.01pH, support for external brands of ElectRode, suitable for harsh industrial environments.
Adapted to BNC interface pH ElectRode, supports 0.0-14 pH range calibrate, adjustable dose relay configuration is higher or lower than the user set point dosing, with timeout dosing protection function, the delay time is adjustable by 5-30 minutes.
Supports 24-hour continuous monitoring of acidity and temperature, Measurement accuracy +/- 0.2pH, resolution 0.1pH, Manual calibration method, suitable for rapid measurement of multiple batches of samples.
Wall-Mounted waterproof structure is equipped with PTFE anti-clogging dialysis membrane, supports 0.0-14 pH Measurement range and +/- 0.2pH accuracy, alarm point can be set at 3-11pH, LED light reminder when the setting exceeds +/- 0.5pH, extending ElectRode life.
Measurement accuracy of +/- 0.05pH, resolution of 0.01pH, pH and mV can be detected at the same time, built-in battery supports 10-15 hours of battery life, easy to operate, stable and reliable.
Measurement accuracy of 0.01 pH, support automatic temperature compensation and pH/mV/temperature Multi-ParaMeter measurement, simple, stable and reliable operation.
Measurement accuracy of +/- 0.02pH, resolution of 0.01pH, support three-point calibrated, built-in Glass electRode, small size weighing only 88g, suitable for 0-50 ℃ environment, easy to quickly detect on site.
Measurement range 0.00-14 pH, accuracy +/- 0.05pH, with temperature compensation function, portable design for easy field use, large screen LCD display is clear and intuitive.
Measurement range 0.00-14 pH, accuracy +/- 0.05pH, with automatic temperature compensation function, portable design for on-site fast detection, repeatability error only +/- 0.03.
Measurement accuracy of +/- 0.1pH with three-point calibrating technology, PH and temperature can be measured simultaneously, compact and portable, suitable for outdoor use.
Using planar pH ElectRode design, Measurement accuracy of 0.01pH, Support 1-3 point Automatic calibration, with automatic temperature compensation and end point locking function, full waterproof structure to ensure harsh environment use.
Glass shell and sensitive membrane, pH Measurement range 0-14pH, Temperature range 5-60 ℃, suitable for routine sample measurement, liquid boundary is ceramic core single salt bridge, reference type Ag/AgCl.
Using external ElectRode design, Measurement accuracy of 0.01pH, support 0.1-14 pH range and 0-50 ℃ temperature measurement, small size for on-site detection and operation.
Using microprocessor control, pH Measurement accuracy of +/- 0.02pH, support three point calibrated (4.01, 6.86, 9.18), simple operation, stable and reliable performance.
With PH/ORP measurement function, Measurement accuracy up to +/- 0.02pH, support temperature automatic compensation and manual compensation, provide high and low limit alarm dual relay, isolated transmitter port maximum loop resistance greater than 300Ω.