$ 3331.00Ex works
Adopt electromagnetic force closed-loop measurement system, Measurement range 0-400mN/m, resolution +/- 0.1mN/m, automatically read equilibrate value, support high viscosity liquid and interfacial tension test, simple operation without external computer control.
Category : Surface Tensiometer
Brand : hengping
SKU : NB010259
Service :The delivery and service By NBCLab.Com
BZY series automatic liquid meter/interfacial tension meter is a laboratory instrument that uses physical methods instead of chemical methods to determine liquid meter/interfacial tension, which can quickly and accurately test the tension value of various liquid-gas surfaces and liquid-liquid interfaces. The instrument adopts a professional electromagnetic force closed-loop force value measurement system and a single-chip microprocessor control. It has the characteristics of automatic measurement, simple operation, excellent performance, High Accuracy, High Stability, High Repeatability and High Linearity of test results. It is widely used in petroleum, chemical, printing, Spinning & weaving, electric power and other industries.
1. Fully automated measurement to minimize human error 2. Automatically read the surface tension equilibrating value 3. One-click clearing (any value between 0-400mN) 4. One-click correction, with random standard weight, accurate and fast 5. Adopt the platinum plate method, which fully meets the basic principles of the Wilhelmy platinum plate method 6. The measurement of surface tension changes at different times due to the presence of surfactants 7. High viscosity liquid measurement (automatically read equilibrate value) 8. Can measure the interfacial tension between two dissolving liquids 9. Sensor responsiveness, high accuracy, good repeability reproducibility 10. Simple operation, no need for any external computer control 11. The machine itself has small errors, effectively controlling various errors during testing 12. Sample thermostatic cup, sample temperature detection device and external Thermostatic bath
The BZY series automatic meter/interfacial tension meter adopts a professional electromagnetic force closed-loop force value measurement system, which is based on the basic principle of Wilhelmy platinum plate method and is controlled by a single-chip microprocessor to realize automatic measurement. The instrument calculates the surface tension or interfacial tension value by measuring the force value of the liquid surface or interface acting on the platinum plate (or platinum ring).
Petrochemicals industry, printing industry, paints Coatings industry, pesticide industry, cleaning agent industry, Eletroplating industry, cosmetics industry, Spinning & weaving industry, food industry, water treatment industry, power industry, biological engineering, research institutes, Universities & colleges
JB/T9388-2002 "interfacial tension meter conditions", GB/T6541-86 "Petroleum product oil to water interfacial tension meter determination (ring method) ", ISO1409-1995 "Rubber & plastics polymer dispersion and emulsion surface finishing for determination", GB/T22237-2008 "Surfactant surface tensiometer determination", GB11278-89 "anion and nonionic surfactants, determination of critical micelle concentration (ring method) ", GB/T18396-2001 "natural emulsion ring method for determination of surface tension", SH/T1156-99 "synthetic rubber surface tension determination method"
1. Instrument preparation: connect the power supply, turn it on and warm up 2. Sample preparation: Place the liquid to be tested in the sample container 3. Instrument clearing: one-click clearing within the range of 0-400mN 4. Instrument correction: One-click correction using the standard weight included with the random 5. Sample test: immerse platinum plate (or platinum ring) in liquid, automatic measurement 6. Data reading: The instrument automatically reads and displays the surface tension equilibrating value 7. Data processing: Connect to the computer through the RS232C interface, and use standard software for Data analysis
• Please read the Operation Manual carefully before use • Power supply voltage AC220V +/- 10% • Platinum plates should be cleaned in time after use to avoid contamination • Wait for the equilibrate value to be automatically read when measuring high viscosity samples • Make sure that the two liquids do not dissolve when performing interfacial tension measurement • Temperature range controlled at 0-110 ℃ when using thermostatic device • Regular instrument calibration using standard weights • Avoid use in humid, vibrating or strong electromagnetic interference environments
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.