Overview
GC9800 networked Gas Chromatograph is a new generation of high-performance intelligent networked Gas Chromatograph independently developed by HENGPING. It inherits the characteristics of GC9800 series of simple structure, reasonable layout, convenient operation and maintenance, and has the advantages of fast cooling of the column box, high detection sensitivity, LCD display, built-in chromatograph workstation, reverse control operation and networked remote supervision.
Features
1. The cooling speed of the column box is fast.
2. High detection sensitivity.
3. Equipped with LCD display.
4. Built-in chromatograph workstation.
5. Support anti-control operations.
6. Equipped with networked remote supervision capabilities.
7. The chromatograph detection signal supports both analog and digital output methods, with strong compatibility.
8. One computer can connect up to 250 Chromatographs for control and data collection.
9. Intelligent design, with six-way temperature control and three-way time program control, can automatically alarm heating faults.
HT300A Automatic sampler can be connected to achieve fully automated unattended sampling and analysis of up to 110 liquid samples.
11. The network function can transmit the operating status and analysis results of the instrument to the enterprise and industry authorities in real time, enabling three-level network supervision.
Principle
The GC9800 (N) Gas Chromatograph separates the mixture through the Chromatography Column. The chromatograph detection signal can be output in analog or digital mode. The analog signal can be connected to the chromatograph processor or workstation; the digital signal is connected to the computer through the network interface, and the built-in workstation is used for real-time data collection, analysis, and reverse control of the Chromatograph operation.
Applications
Oil and Gas Fields, Petrochemicals, Fine Chemicals, Coal Chemicals, Gas, Food, Agriculture, Environmental Protection, Scientific Research
Steps
1. Select the analog or digital signal output method to connect the device as needed.
2. If using digital signals, connect the instrument to the computer through a network interface.
3. Perform parameter setting, start analysis and real-time data collection through the built-in chromatograph workstation software on the computer.
4. HT300A Automatic sampler can be installed to achieve automatic sampling and analysis after setting the sample sequence.
5. Transmit analytical data to relevant regulatory authorities through network functions.
Notice
• Instrument Ambient Temperature should be between 5-35 ℃.
• The relative humidity of the working environment should be ≤ 85%.
• Power frequency should be 220V +/- 10%, frequency 50Hz +/- 0.5Hz.
• The instrument can automatically alarm for heating faults, please pay attention to the relevant warning information.
• Make sure the connection is correct before use and select the appropriate signal output method according to the analysis requirements.