Overview
YIHENG LRH-50CB cryogenic incubator is an efficient and energy-saving equipment, using brand Compressor and circulating fan, high efficiency, low energy consumption, more than 40% reduction in cooling time compared with traditional cryogenic equipment, long service life and low noise. It is widely used in the storage of foster base, serum, products and microbial foster, environmental testing and other fields.
Features
1. Mirror stainless steel liner, four corners semicircular arc transition, shelf bracket can be freely loaded and unloaded, easy to clean.
2. Microcomputer temperature controller, which quickly reaches the set value and operates accurately and stably (standard digital controller).
3. Brand Compressor and circulating fan, ring · Bao · type refrigerant (R134a), high efficiency, low energy consumption, promote energy saving.
4. There is a 25mm diameter test hole on the left side of the box, which is convenient for experimental operation and Measuring temperature.
5. Independent temperature limit alarm system, exceeding the limit temperature automatically interrupts to ensure experimental safety (standard).
6. Can be equipped with a printer or RS485 interface to record temperature parameter changes (optional).
7. Multi-stage programming function, Menu-type Operating interface, simplifies the complex test process, and realizes automatic control (optional).
8. LCD multi-segment programmable controller (optional), Multi-Parameter one-screen display, can set temperature, circulating wind speed, time, heating rate, etc., preset 7 sets of 63-step programs, each set of 9 steps, time 1~ 9999 minutes.
Principle
The cryogenic incubator precisely controls the temperature through a microcomputer temperature controller, uses brand-name Compressors and circulating fans to achieve efficient refrigeration and air circulation, and uses ring-type refrigerant (R134a) to reduce energy consumption. Multi-stage programming allows users to set complex temperatures Linear dispersion for automatic control and operation.
Applications
Storage foster base, serum, product, microbial foster, environmental testing
Steps
1. Connect the power supply (AC 220V 50Hz).
2. Set the required temperature parameters through the microcomputer temperature controller.
3. Optional multi-stage programming function, preset temperature, time and other programs.
4. Start the device and monitor the running status.
5. Use test holes for experimental operation and temperature measurement.
6. After the experiment, turn off the power and clean the liner.
Notice
- Ensure that the Working Ambient Temperature is within the range of + 5~ 35 ° C.
- Power supply voltage is checked before use to meet AC 220V 50Hz requirements.
- Avoid overloading, install up to 4 shelves.
- Clean the liner regularly and maintain hygiene.
- Pay attention to the independent temperature limit alarm system to prevent the temperature from exceeding the limit.
Optional features require additional configuration, such as a printer or RS485 interface.