Overview
YIHENG LRH-100CL cryogenic incubator is a high-efficiency and energy-saving equipment, using brand Compressors and circulating fans, with high efficiency and low energy consumption. Compared with traditional cryogenic equipment, the cooling time is reduced by more than 40%, and the service life is long and the noise is low. Widely used in the storage of foster bases, serums, products and microbial foster, environmental testing and other fields.
Features
1. Mirror stainless steel liner, four corners semicircular arc transition, shelf bracket can be freely loaded and unloaded, easy to clean.
2. Microcomputer temperature controller that quickly reaches the set point and operates accurately and stably.
3. Brand Compressor and circulating fan, environmentally friendly refrigerant (R134a), high efficiency, low energy consumption and energy saving.
4. There is a 25mm diameter test hole on the left side of the box, which is convenient for experimental operation and Measuring temperature.
5. Independent temperature limit alarm system, exceeding the limit temperature automatically interrupts to ensure safety.
6. Can be equipped with a printer or RS485 interface to record temperature parameter changes (optional).
7. Multi-stage programming function, Menu-type Operating interface, simplifies the complex test process, and realizes automatic control (optional).
8. LCD multi-segment programmable controller, Multi-Parameter one-screen display, can set temperature, circulating wind speed, time, etc., preset automatic boot, standby and shutdown (optional).
9. 7 groups of 63 steps can be programmed, each group of 9 steps, and the setting time is 1 to 9999 minutes.
Principle
The cryogenic incubator drives the environmentally friendly refrigerant (R134a) through the brand Compressor and circulating fan for refrigeration cycle. The microcomputer temperature controller precisely adjusts the temperature in the box to quickly reach the set value and maintain stability. The multi-stage programming function allows the user to preset the temperature, time and other parameters to realize automatic control and layer heating to ensure the accuracy and reliability of the experimental process.
Applications
Storage foster base, serum, product, microbial foster, environmental testing
Steps
1. Connect the power supply (AC 220V 50Hz).
2. Set the required temperature parameters through the microcomputer temperature controller.
3. Optional multi-stage programming function, preset temperature, time and other programs.
4. Start the equipment and monitor temperature fluctuations and operating status.
5. Use test holes for experimental operation and temperature measurement.
6. After the experiment, turn off the power and clean the liner.
Notice
• Ambient Temperature should be maintained at + 5~ 35 ℃.
• Power supply voltage is AC 220V 50Hz to avoid overload.
• Regularly clean liners and shelves to prevent contamination.
• Pay attention to the independent temperature limit alarm system to prevent the temperature from exceeding the limit.
• Optional functions such as printer or multi-stage programming need to be operated according to the instructions.
• Device weight (Net weight 130Kg) to avoid damage.