Overview
YIHENG LRH-150CA cryogenic incubator is an efficient and energy-saving equipment, using brand Compressor and circulating fan, high efficiency, low energy consumption, more than 40% reduction in cooling time compared with traditional cryogenic equipment, long service life and low noise. It is widely used in storage of foster base, serum, products and microbial foster, environmental testing and other fields.
Features
1. Mirror stainless steel liner, four corners semicircular arc transition, shelf bracket can be freely loaded and unloaded, easy to clean.
2. Microcomputer temperature controller, which quickly reaches the set value and operates accurately and stably (standard digital controller).
3. Brand Compressor and circulating fan, environmentally friendly refrigerant (R134a), high efficiency, low energy consumption and energy saving.
4. There is a 25mm diameter test hole on the left side of the box, which is convenient for experimental operation and temperature measurement.
5. Independent temperature limit alarm system, exceeding the limit temperature automatically interrupts to ensure experimental safety (standard).
6. Can be equipped with a printer or RS485 interface to record temperature parameter changes (optional).
7. Multi-stage programming function, Menu-type Operating interface, simplifies the complex test process, and realizes automatic control (optional).
8. LCD multi-segment programmable controller (optional), Multi-Parameter one-screen display, can set temperature, circulating wind speed, time, heating rate, etc., preset 7 sets of 63-step programs, each set of 9 steps, time 1~ 9999 minutes, support automatic boot, standby and shutdown.
Principle
The cryogenic incubator precisely controls the temperature with a microcomputer temperature controller, uses a brand-name Compressor and circulating fan for efficient cooling and air circulation, and uses an environmentally friendly refrigerant (R134a) to reduce energy consumption. Multi-stage programming allows users to set complex parameters for automatic control and operation.
Applications
Storage foster base, serum, product, microbial foster, environmental testing
Steps
1. Connect the power supply (AC 220V 50Hz).
2. Set the required temperature and Miscellaneous parameters (e.g. time, circulating wind speed) through the microcomputer temperature controller.
3. For complex control, use the multi-stage programming function to preset the program (optional).
4. Start the equipment, monitor the running status, and if necessary, Measuring temperature through the test hole.
5. After the experiment, turn off the equipment and clean it.
Notice
• Ensure that the Working Ambient Temperature is within the range of + 5~ 35 ° C.
• Power supply voltage check before use meets AC 220V 50Hz requirements.
• Regularly clean the liner to avoid contamination.
• Pay attention to the independent temperature limit alarm system to prevent the temperature from exceeding the limit.
• Optional functions such as printers or multi-segment programming require additional configuration.
• Device weight (Net weight 180Kg) to avoid damage.