Overview
YIHENG DHP-9602 Electric heated incubators of constant temperature is a High Accuracy thermostatic device with fuzzy PID controller, accurate temperature control with small fluctuations and timing function. Equipped with forced convection air duct system and mirror stainless steel liner, the heating speed is fast and uniform, suitable for experimental environments such as cell foster.
Features
1. Fuzzy PID controller, with accurate temperature control and small fluctuations, with timing function, the maximum setting value of time is 99 hours and 59 minutes.
2. Forced convection duct system to improve Temperature Response Speed, Improve Temperature uniformity and reduce temperature fluctuations.
3. Glass door inside the box door, easy to observe, Glass door open when the breeze circulation and heating automatically stop.
4. Mirror stainless steel liner, Electric heating film Heating mode, heating speed, uniform heating in the box.
5. Independent temperature limit alarm system (optional), which automatically interrupts when the temperature exceeds the limit to ensure safety.
6. Can be equipped with a printer or RS485 interface (optional) to record temperature parameter changes.
7. The speed of the circulating fan is automatically controlled, and the wind speed is reduced when the thermostatic is used to avoid the volatilization of the sample.
8. Multi-stage programmable controller (optional), multi-stage temperature, circulating wind speed, time and heating rate parameters can be programmed.
9. Safety features include high or low temperature and over-temperature alarm.
10. UV sterilization system (optional), regularly disinfect the box to prevent contamination.
Principle
The incubator precisely adjusts the temperature through the fuzzy PID controller, and uses the electric heating film Heating mode to quickly and evenly heat the space in the box. The forced convection air duct system automatically controls the wind speed through the circulating fan to improve the temperature Response and uniformity, and automatically stops the circulation and heating when the box door is opened to prevent temperature overshoot.
Applications
Cell fostering, biological experiments, scientific research and education, pharmaceutical research and development
Steps
1. Connect the power supply to AC 220V 50Hz.
2. Temperature range RT + 5~ 65 ℃ and timing function (maximum 99 hours 59 minutes).
3. Select a multi-stage programmable controller as required to set parameters such as temperature, wind speed, and time.
4. Start the device and monitor Temperature Uniformity +/- 2.0 ° C and Fluctuation +/- 0.5 ° C.
5. After use, an optional ultraviolet sterilization system can be used for disinfection.
Notice
• Ambient Temperature should be maintained at + 5~ 35 ℃.
• Glass doors open, breeze circulation and heating automatically stop to avoid temperature overshoot.
• When selecting an independent temperature limit alarm system, pay attention to the automatic interruption function of overtemperature.
• The circulating fan speed is automatically reduced in the thermostatic state to prevent the sample from evaporating.
• When using optional functions such as printers or multi-segment programming, follow the instructions.