Overview
The KANGGUANG WSD-5 Handheld whiteness meter is a Portable measuring instrument for fast measurement of whiteness and various surface color parameters of objects in the field. It uses 45/0 observation conditions to effectively eliminate the influence of surface Gloss on measurement, and has intelligent memory and stable measurement functions.
Features
1. Small size, light weight, easy to carry, suitable for various on-site measurement operations.
2. Using an effective Illuminant system, the number of measurements can reach more than 100,000 times.
3. The 45/0 observation condition is used to completely eliminate the influence of the surface gloss of the measured object on the whiteness metric.
4. Low power consumption, extremely power-saving, powered by five AA alkaline batteries, can be used continuously for three months, and is equipped with AC adapter power supply.
5. The test speed is fast, and a measurement operation can be completed within 3 seconds.
6. The measurement data is stable and the repeatability is good.
7. High-definition LCD display, Chinese prompt operation.
8. Intelligent memory system, after the instrument is initialized, there is no need to perform calibrating operations such as preheating, zero adjustment and whitening during general measurement.
9. Automatic power-off function. If there is no operation after the instrument is powered on, it will automatically power off and shut down after 20 minutes to save power consumption.
10. measurement operation error alarm prompt.
11. Equipped with RS232 communication interface, it can be easily connected to computers and printers.
12. Low battery prompt function prompts the user to replace the battery to ensure accurate and effective measurement operation.
Principle
The instrument uses 45/0 observation conditions (ie 45 degrees ring illumination, 0 degrees reception) for measurement. This Optical inspection structure can effectively eliminate the influence of the surface Gloss of the measured object on the whiteness measurement results. The instrument irradiates the sample through the built-in Illuminant system and receives the reflected light signal. After calculation by the internal processing system, the whiteness value and various color parameters are displayed on the LCD screen.
Applications
Suitable for all kinds of field operations requiring measurement of whiteness and Color
Standards
Meets GB5950 whiteness measurement standard
Steps
1. Press the power switch button to start the instrument.
2. If you need to calibrate, use the calibrate button to zero and whiten (this step can be omitted for general measurement after initialization).
3. Align the measurement sample light hole with the sample to be tested.
4. Press the measurement operation button for measurement, which will be completed in about 3 seconds.
5. Read the data displayed on the LCD liquid crystal display.
6. After the measurement is completed, you can press the reset button to put the instrument in the ready measurement state, or wait for its automatic shutdown.
Notice
● Ensure that the sample size meets the requirements during measurement (diameter > 18mm, Film thickness < 40mm).
● The instrument should be used at the specified operating temperature (0-40 ° C).
● Pay attention to the battery power, when there is a low battery prompt, the battery should be replaced in time to ensure the accuracy of measurement.
When using an AC adapter for power supply, ensure that the voltage meets the requirements (220V +/- 10% 50Hz).
After the instrument is automatically powered off, it needs to be restarted if it needs to be used again.
● Avoid measurement operation errors and pay attention to the instrument prompt information.