Overview
YIHENG BPHJS-1000A High and Low Temperature (Alternating) Damping heat testing chamber is a new generation of Environmental performance equipment. It integrates the company's many years of box design experience and adopts humanized design concepts. Starting from the actual needs of customers, it meets the requirements in details and provides high-quality products.
Features
1. Humanized design: Fluorine-free health design, wet and dry ball type or electric kiln type multi-functional multi-stage programmable temperature and Humidity controller, long life of imported temperature and Humidity controller, High Accuracy LCD display, test hole on the left side of the box, built-in sink can be pulled out to add water.
2. Quality assurance: brand Compressor and circulating fan, environmentally friendly refrigerant R134a, unique air duct circulation system, imported 304 mirror stainless steel liner, multi-stage programmable control.
3. Safety functions: independent temperature limit alarm system, high and low temperature and over-temperature alarm, Compressor overheating and overcurrent overload protection, fan overheating protection, water shortage protection.
4. Convenient data processing: Can connect printer or 485 Communication interface, USB data transfer interface, computer display and printing Temperature Humidity Time Linear dispersion.
5. Programmable Touchscreen Controller: Color LCD Touch Control Screen, Chinese and English Operating interface, 100 sets of programs can be preset, screen lock function, P.I.D automatic calculation function, RS-232 or RS-485 Communication interface, Computer Professional Control Software supports multi-device monitoring.
Principle
Adopt wet and dry ball or electric kiln multi-functional multi-stage programmable temperature and Humidity controller and fuzzy PID controller to achieve accurate temperature and humidity control with small fluctuation. Through brand Compressor and circulating fan combined with environmentally friendly refrigerant R134a, and unique air duct circulation system, ensure uniform distribution of temperature and Humidity in the working room.
Applications
Environment Testing, Product Research & Development, mass inspection
Steps
1. Use keyboard input or Touchscreen to operate the Humidity Controller.
2. Preset program groups and steps, and set time parameters.
3. Experimental operation and temperature measurement through the test hole.
4. Pull out the built-in sink and add water.
5. Connect a computer or printer for data processing and monitoring.
Notice
When the temperature limit is exceeded, the system automatically interrupts and alarms to ensure safe operation.
• Pay attention to Compressor overheating, overcurrent, overload protection, and fan overheating and water shortage protection.
• Use the screen lock function to avoid human error.
• Power supply voltage AC380V 50Hz to avoid power mismatch.