Overview
YIHENG GHP-9080N Water-Jacketed thermostatic incubator adopts Water-jacketed Heating mode, Temperature range is RT + 5~ 65 ℃, Temperature Fluctuation +/- 0.3 ℃, Uniformity +/- 0.5 ℃ (37 ℃). The product has the characteristics of humanized design, automatic control of circulating wind speed and multi-stage programmable control, which is suitable for experimental environments such as cell foster.
Features
1. Brushed stainless steel liner, four corners and half circle arc transition, free loading and unloading of shelves for easy cleaning
2. Water-Jacketed Heating mode ensures uniform temperature, and can still maintain thermostatic for a long time after power failure
3. Observe Glass door design, automatically suspend work and cut off heating and fan when opening the door
4. Microcomputer controller with self-tuning PID technology to avoid temperature overshoot
5. Automatic control of circulating fan speed, reduce wind speed when thermostatic to avoid sample volatilization
6. Multi-segment programmable controller, one-screen display of a variety of parameters, Menu Operating interface
7. Independent temperature limit alarm system, sound and light alarm prompt
8. With alarm functions such as abnormal temperature, water shortage and long door opening time
9. Optional UV sterilization system to prevent cell fostering contamination
Principle
Adopt Water-Jacketed Heating mode to ensure uniform temperature distribution in the studio through Water-jacketed heating system. The microcomputer controller uses self-tuning PID technology to precisely control the temperature, the circulating fan speed is automatically adjusted according to the temperature state, and the wind speed is reduced in the thermostatic state to facilitate cell growth.
Applications
Cell fostering, microbial fostering, biological experiments, medical research
Steps
1. Connect the AC220V 50Hz power supply
2. Set temperature, time and other parameters through multi-stage program LCD controller
3. Set the circulating wind speed and heating rate as required
4. Start the device and start working
5. Glass doors can be viewed at any time
6. After the experiment is completed, shut down according to the specified procedures
Notice
• Ambient Temperature should be kept within the range of + 5~ 35 ℃
The opening time should not be too long, otherwise the alarm will be triggered
• Pay attention to water level monitoring to avoid water shortage alarms
• Regularly clean the studio to maintain hygiene
• Check whether each alarm function is normal before use
• When choosing RS485/232 and printer, you can only choose one of the two.