Overview
RONGHUA INSTRUMENT DHG-9202-0 electric thermostatic drying oven is a laboratory equipment heated by electric heating, its Inner chamber dimensions are 350 × 350 × 350mm, the volume is 50L, Temperature range is room temperature + 10 ℃ to 300 ℃, suitable for sample drying, baking, heat treatment and other thermostatic environment requirements.
Features
1. Using intelligent digital display temperature control instrument, the operation is intuitive and convenient.
2. Equipped with an observation window, it is convenient to observe the sample status in the box in real time.
3. Provide iron liner version to meet different application needs.
4. Temperature Fluctuation, temperature control accuracy up to +/- 1 ℃.
Principle
The drying oven generates heat through the built-in electric heater, and uses forced convection or natural convection to evenly heat the air in the working room. The intelligent digital display temperature control instrument monitors the temperature in the box in real time, and adjusts the power output of the heater through the control system, thereby accurately maintaining the temperature of the studio near the target value set by the user to achieve thermostatic control.
Applications
Laboratory sample drying, material baking, workpiece heat treatment, thermostatic aging test
Steps
1. Place the equipment in a smooth, well-ventilated environment.
2. Turn on the power supply and turn on the power switch.
3. Set the required operating temperature through the intelligent digital display thermostat.
4. Put the sample to be processed into the studio and close the box door.
5. The device starts to heat up and enters a thermostatic state after reaching the set temperature.
6. After the work is completed, turn off the heating switch and power switch, and wait until the temperature in the box drops to a safe range before taking out the sample.
Notice
* Equipment should be placed in a well-ventilated environment free of flammable and explosive materials.
* Do not put wet or corrosive items directly into the box, so as not to damage the liner or affect the life of the equipment.
When taking samples, please pay attention to high temperatures to avoid burns.
* During the operation of the equipment, do not switch the door frequently, so as not to affect the temperature stability and energy consumption.
Clean the equipment regularly to keep the inside and outside clean, but please disconnect the power supply when cleaning.
* If not in use for a long time, please disconnect the power supply of the device.