Overview
The CH3006 Super Thermostatic bath adopts a microcomputer intelligent Control system and an imported PT100 temperature sensor. It has the function of breaking couple protection and over-temperature alarm. Temperature Fluctuation is up to +/- 0.05 ° C and Display resolution is up to 0.1 ° C. The product is equipped with a circulating pump to lead the thermostatic liquid in the tank to establish a second thermostatic field. The inner tank and the box are made of stainless steel, and the pump Flow rate is 8L/min. This series of products offers a variety of specifications. Temperature range up to 300 ° C, liner volume is available in 6 liters and 15 liters.
Features
1. Microcomputer Intelligent Control system
2. Imported PT100 temperature sensor
3. With breaking protection and over-temperature alarm function
4. Temperature Fluctuation up to +/- 0.05 ℃
5. Display resolution up to 0.1 ℃
6. Flow rate of pump is 8L/min
7. The inner tank and box are made of stainless steel
8. A second thermostatic field can be established with a circulating pump
9. Excellent wear resistance and corrosion resistance
Principle
Thermostatic bath achieves precise temperature control through microcomputer intelligent Control system and PID adjustment, and adopts imported PT100 temperature sensor to monitor temperature in real time. The built-in circulating pump can lead the thermostatic liquid outside the tank to establish a second thermostatic field, providing a constant environment with uniform temperature for the experiment.
Applications
Bioengineering, Food, Chemical, Metallurgy, Chemical Analysis, Petroleum, Research Institute, Colleges and Universities, Factory Laboratory, Quality control department
Steps
1. Select the appropriate Temperature range and liner volume specifications according to the experimental requirements
2. Place the thermostatic sample or equipment in the Tank
3. Set the required temperature parameters
4. Start the device to start thermostatic control
5. If an external thermostatic field is required, the circulation pump function can be enabled
6. Monitor the operating status of the equipment to ensure stable temperature
Notice
• Please confirm whether the equipment specifications meet the experimental requirements before use
• Note that the temperature setting must not exceed the maximum temperature of the equipment by 300 ° C.
Regularly check whether the temperature sensor and protection function are normal
• Keep the equipment clean and avoid direct contact with corrosion substances
• Pay attention to the firm connection of the pipeline when using the circulating pump
• Do not move or disassemble the equipment at will during operation