Overview
The TDSscan20 is a pen TDS meter from the BANTE brand for the measurement of total dissolved solids (TDS) values in various liquids. The meter has a multi-range design, supports 1 to 3 point button calibrating, and has built-in automatic temperature compensation. It can customize 5 function parameters through the system menu. Measurement accuracy is 1% F.S.
Features
1. Multi-range pen TDS meter, covering low, medium and high ranges
2. Platinum Electrode Sensor for fast and stable measurement results
3.1 to 3 point button calibrated, automatically identify TDS standard solution
4. Adjustable TDS conversion factor to ensure accurate measurement of different water quality
5. Automatic temperature compensation to ensure accurate measurement of full scale
6. Automatic end point locking, maintaining stable readings for easy browsing or recording
7. Low battery alarm icon, prompting battery residual power
8. Automatic power off, effectively saving battery energy consumption
9. Built-in system menu, can customize the number of calibrated points, temperature unit, data lock mode, shutdown mode and other 5 function parameters
10. One-click reset (Reset), automatically restore the meter to the factory default settings
11. Replaceable Electrode Reduces Instrument Maintenance and Use Costs
12. Full waterproof performance to ensure complete protection of the instrument in harsh environments
Principle
The meter calculates the total dissolved solids (TDS) value using the Platinum Electrode Sensor measurement of liquid conductivity, combined with the TDS conversion factor and automatic temperature compensation. The built-in system supports multi-range switching and calibrating to ensure accurate measurement under different water quality conditions.
Applications
Research and education, water and wastewater treatment, environment monitoring, Eletroplating and printing industry, aquaculture and hydroponics, drinking water and other industrial applications
Steps
1. Turn on the meter power
2. Choose the number of calibrating points (1 to 3 points) as needed and calibrate with standard solution
3. Electrode immersion in the liquid to be tested
4. Instrument automatic temperature compensation and measurement
5. Automatic locking after stable reading for easy recording
6. Clean Electrode and Power Off After Use
Notice
• Make sure Electrode is clean and free of contamination before use
• The specified TDS standard solution should be used when calibrating
Avoid prolonged use in extreme temperature environments
• Regularly check the battery power and replace it in time
• When the meter is not in use, it is recommended to turn off the power to save power
• Please use the specified model when replacing Electrode
• Fully waterproof design but still need to avoid long-term immersion in corrosion liquids