Overview
The SALscan10 pen Salinometer is a low concentration pen Salinometer with conductivity measurement, 1 to 3 point calibrating and automatic temperature compensation. The built-in system menu can customize 5 function parameters for the measurement of salinity and conductivity of conventional liquids. Measurement accuracy is 1% F.S.
Features
1. Low concentration pen Salinometer, including conductivity measurement function
2. Platinum Electrode Sensor for fast and stable measurement results
3.1 to 3 point button calibrate, can use custom calibrating liquid
4. Automatic temperature compensation, providing accurate Measured value in the full range
5. Automatic end point locking, maintaining stable readings for easy browsing or recording
6. Low battery alarm icon, prompting battery residual power
7. Automatic power off, effectively saving battery energy consumption
8. Built-in system menu, can customize the number of calibrated points, temperature units, automatic or manual data locking, timing or manual shutdown and other 5 function parameters
9. One-click reset (Reset), automatically restore the meter to the factory default settings
10. Replaceable Electrode Reduces Instrument Maintenance and Use Costs
11. Full waterproof performance to ensure complete protection of the instrument in harsh environments
Principle
The meter uses the Platinum Electrode Sensor to measure the conductivity of liquids, combined with automatic temperature compensation to provide accurate salinity and conductivity values over the full range. The built-in system menu allows users to customize multiple parameters to ensure that the measurement adapts to different application scenarios.
Applications
Research and education, food testing, aquariums, physiologicalsaline configuration, beverage industry and other industrial applications
Steps
1. Turn on the meter power
2. Select the number of calibrating points as needed and calibrate
3. Electrode immersion in the liquid to be tested
4. Wait for the reading to stabilize, and the meter can automatically or manually lock the data
5. Record measurement results
6. Clean Electrode and Power Off After Use
Notice
• Make sure Electrode is clean and free of contamination before use
• Appropriate calibrating fluid should be used when calibrating
Avoid prolonged use in extreme temperature environments
• Regularly check the battery power and replace it in time
• When the meter is not in use, it is recommended to turn off the power to save energy consumption
• When replacing Electrode, please select the model specified by the original factory
• Fully waterproof design but still need to avoid long-term immersion in corrosion liquids